FIELDVUE DVC6200 Digital ValveController / Magnet Assembly DimensionsDigital Valve ControllerConfiguration(1)MountingFigure PageDVC6200 DVC6200 SISDVC6200fDVC6200pIntegral mounting to the Fisher 657/667 size ior GX actuatorWith integrally mounted filter regulator11, 2 Integral mounting to Fisher rotary actuatorsSliding-stem linear applicationsQuarter-turn rotary applicationsDVC6205 DVC6205 SISDVC6205f DVC6205pRemote mount base unit 2 3 DVC6215 Feedback unit 3 41. DVC6200 Digital Valve controllers can also be mounted on other actuators that comply with IEC 60534-6-1, IEC 60534-6-2, VDI/VDE 3845 and NAMUR Assembly(1)FigurePageStem #1919 mm / 3/4 inch4 4 Stem #2525 mm / 1 inch5 4 Stem #3838 mm / 1-1/2 inch6 5 Stem #5050 mm / 2 i

DVC6200 Digital Valve Controller D103543X012 Product Bulletin 62.1:DVC6200(S1) September 2017 4 150.3 (5.92) GE53725 Mounting hole locations for the DVC6215 feedback unit are the same as for the DVC6200, DVC6200 SIS, DVC6200f, and DVC6200p digital valve controller. Refer to the back view in figure 1. 1/2-14 NPT CONDUIT CONNECTION BOTH SIDES 1/4 ...

Tags:

  Controller, Valves, Digital, Dvc6200f, Digital valve controller

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Product Bulletin DVC6200 Digital Valve Controller ...

1 FIELDVUE DVC6200 Digital ValveController / Magnet Assembly DimensionsDigital Valve ControllerConfiguration(1)MountingFigure PageDVC6200 DVC6200 SISDVC6200fDVC6200pIntegral mounting to the Fisher 657/667 size ior GX actuatorWith integrally mounted filter regulator11, 2 Integral mounting to Fisher rotary actuatorsSliding-stem linear applicationsQuarter-turn rotary applicationsDVC6205 DVC6205 SISDVC6205f DVC6205pRemote mount base unit 2 3 DVC6215 Feedback unit 3 41. DVC6200 Digital Valve controllers can also be mounted on other actuators that comply with IEC 60534-6-1, IEC 60534-6-2, VDI/VDE 3845 and NAMUR Assembly(1)FigurePageStem #1919 mm / 3/4 inch4 4 Stem #2525 mm / 1 inch5 4 Stem #3838 mm / 1-1/2 inch6 5 Stem #5050 mm / 2 inch7 5 SStem #110110 mm / 4 1/8 inch8 6 SStem #210210 mm / 8-1/4 inch9 6 RShaft #1 / LRC(2)Fisher 2052 Size 2 & 3, 1051/1052 Size 40-70, 1061 Size 30-100, Sliding Stem > 210 mm ( inches)10 7 RShaft #2 / LRC(2)

2 2052 Size 1, 1051/1052 Size 20-3310 7 RShaft End90 degree11 81. Linear magnet assembly width dimensions are shown in figure Linear Roller 1. FIELDVUE DVC6200 , DVC6200 SIS, dvc6200f , and DVC6200p Digital Valve Controller with IntegrallyMounted Filter Regulator1/4-18 NPTOUTPUT CONN AFISHER 67 CFR1/4-18 NPT SUPPLY CONN1/4-18 NPTOUTPUT CONN B3/8-18 NPTVENT ( ) ( ) ( )1/2-14 NPTCONDUIT CONNBOTH ( ) ( ) ( )mm(INCH) DVC6200 Digital Valve ControllerD103543X012 Product : DVC6200 (S1)September 2017 DVC6200 Digital Valve ControllerD103543X012 Product : DVC6200 (S1)September 2017 2M8 X ( ) ( )57( ) ( )35( ) ( ) ( ) ( )M6 X ( ) ( )Figure 1.

3 FIELDVUE DVC6200 , DVC6200 SIS, dvc6200f , and DVC6200p Digital Valve Controller with IntegrallyMounted Filter Regulator (continued)BACK VIEW(REGULATOR NOT SHOWN) ( ) ( ) ( ) ( )mm(INCH)1 1 Housing insert for SSTEM #210 magnet assembly (figure 9) inserted Digital Valve ControllerD103543X012 Product : DVC6200 (S1)September 2017 3 Figure 2. FIELDVUE DVC6205, DVC6205 SIS, DVC6205f, and DVC6205p Remote Mount Base Unit Envelope ( ) ( ) ( )1/4-18 NPTOUTPUTCONNECTION A1/4-18 NPTOUTPUTCONNECTION BGE537221/2-14 NPTCONDUITCONNECTIONBOTH SIDES1/2-14 NPTCONDUITCONNECTIONBOTH ( ) ( ) ( )233( ) ( )132( )mm(INCH) DVC6200 Digital Valve ControllerD103543X012 Product .

4 DVC6200 (S1)September 2017 ( )GE53725 Mounting hole locations for the DVC6215 feedback unit are the same as for the DVC6200 , DVC6200 SIS, dvc6200f , and DVC6200p Digital Valve Controller . Refer to the back view in figure NPTCONDUITCONNECTIONBOTH SIDES1/4-18 NPTAIR PASSAGE(HOUSING A ONLY) ( ) ( )Figure 3. FIELDVUE DVC6215 Feedback Unit Envelope Dimensions mm(INCH)Magnet AssembliesFigure 4. SStem #19 Magnet Assembly (Also see in figure 6)8 - 19 mm ( - INCH) TRAVEL ( ) ( ) ( )32( )18( ) ( )M4 X - 6G (ALUMINUM)M5 X X 12 (SST)2mm(INCH)Figure 5.

5 SStem #25 Magnet Assembly(Also see in figure 6) ( )18( )32( ) ( ) ( ) ( )M4 X - 6G (ALUMINUM)M5 X X 12 (SST)20 - 25 mm ( - INCH) TRAVEL RANGE2mm(INCH) DVC6200 Digital Valve ControllerD103543X012 Product : DVC6200 (S1)September 2017 5 Figure 6. SStem #38 Magnet Assembly26 - 38 mm ( - INCH) TRAVEL ( ) ( ) ( )32( ) ( ) ( ) ( )2218( )mm(INCH)M4 X - 6G (ALUMINUM)M5 X X 12 (SST)Figure 7. SStem #50 Magnet Assembly (Also see in figure 6)39 - 50 mm ( - INCH) TRAVEL ( ) ( )10( ) ( ) ( ) ( )18( )2mm(INCH)M4 X - 6G (ALUMINUM)M5 X X 12 (SST) DVC6200 Digital Valve ControllerD103543X012 Product : DVC6200 (S1)September 2017 6 Figure 8.

6 SStem #110 Magnet Assembly (Also see in figure 6)51 - 110 mm ( - INCH) TRAVEL ( ) ( )10( ) ( ) ( ) ( )18( )2mm(INCH)M4 X - 6G (ALUMINUM)M5 X X 12 (SST)Figure 9. SStem #210 Magnet Assembly (Also see in figure 6)111 - 210 mm ( - INCH) TRAVEL ( ) ( ) ( ) ( )58( )18( ) ( )2 HOUSING INSERT FOR SSTEM #210 MAGNET ( ) ( )mm(INCH) 1 Refer to back view of figure 1 for housing insert X - 6G (ALUMINUM)M5 X X 12 (SST) DVC6200 Digital Valve ControllerD103543X012 Product : DVC6200 (S1)September 2017 7 Figure 10.

7 RShaft Window Magnet AssembliesBRACKETBRACKETSPRING, ( ) ( ) ( )109( )74( ) ( )194( ) ( ) ( ) ( )5 X j 9 ( ) THRU4 X j ( ) ( ) ( )57( )RSHAFT WINDOW #1 RSHAFT WINDOW #2 SPRING, ( ) ( )mm(INCH) DVC6200 Digital Valve ControllerD103543X012 Product : DVC6200 (S1)September 2017 8 Figure 11. RShaft End Mount Magnet Assembly4 X j ( ) THRUj 22 ( ) ( )j 28 ( ) ( ) ( )mm(INCH)Related Documentsn Bulletin : DVC6200 DVC6200 Digital Valve Controller (D103415X012)n Bulletin : DVC6200 SISDVC6200 SIS Digital Valve Controller (D103555X012)n Bulletin :DVC6200fDVC6200f Digital Valve Controller (D103399X012)n Bulletin :DVC6200pDVC6200p Digital Valve Controller (D103564X012)All documents are available from your Emerson salesoffice or Local Business Partner.

8 Also visit our websiteat Automation SolutionsMarshalltown, Iowa 50158 USAS orocaba, 18087 BrazilCernay, 68700 FranceDubai, United Arab EmiratesSingapore 128461 contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are notto be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales aregoverned by our terms and conditions, which are available upon request.

9 We reserve the right to modify or improve the designs or specifications of suchproducts at any time without 2011, 2017 Fisher Controls International LLC. All rights and FIELDVUE are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. EmersonAutomation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of theirrespective Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenanceof any Product .

10 Responsibility for proper selection, use, and maintenance of any Product remains solely with the purchaser and end user.


Related search queries