Example: bankruptcy

Product Data - dms.hvacpartners.com

PG96 VAT. TWO--STAGE, 4--WAY MULTIPOISE. VARIABLE--SPEED. CONDENSING GAS FURNACE. Product data STANDARD FEATURES. S All sizes meet ENERGY STARR Version criteria for gas furnaces: 95+AFUE; AMACF electrical rating; 2% or less cabinet airflow leakage. S Ideal height 35 (889 mm) cabinet: short enough for taller coils, but still allows enough room for service. S Silicon Nitride Hot Surface Igniter. S 4--way multipoise design for upflow, downflow or horizontal installations, with unique vent elbow and optional through-- the--cabinet downflow venting capability. S Full--featured variable--speed blower motor, two--speed inducer motor, and two--stage gas valve. S Self--diagnostics. S Adjustable blower speed for cooling, continuous fan, and dehumidification.

1 Product Data PG96VAT TWO--STAGE, 4--WAY MULTIPOISE VARIABLE--SPEED CONDENSING GAS FURNACE A11300 The two--stage gas valve is at the heart of the comfort provided by

Tags:

  Product, Data, Product data

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Product Data - dms.hvacpartners.com

1 PG96 VAT. TWO--STAGE, 4--WAY MULTIPOISE. VARIABLE--SPEED. CONDENSING GAS FURNACE. Product data STANDARD FEATURES. S All sizes meet ENERGY STARR Version criteria for gas furnaces: 95+AFUE; AMACF electrical rating; 2% or less cabinet airflow leakage. S Ideal height 35 (889 mm) cabinet: short enough for taller coils, but still allows enough room for service. S Silicon Nitride Hot Surface Igniter. S 4--way multipoise design for upflow, downflow or horizontal installations, with unique vent elbow and optional through-- the--cabinet downflow venting capability. S Full--featured variable--speed blower motor, two--speed inducer motor, and two--stage gas valve. S Self--diagnostics. S Adjustable blower speed for cooling, continuous fan, and dehumidification.

2 S Aluminized--steel primary heat exchanger. S Stainless--steel condensing secondary heat exchanger. S Propane convertible (See Accessory list). S Factory--configured ready for upflow applications. S Fully--insulated casing including blower section. S Convenient Air Purifier and Humidifier connections. S Direct--vent/sealed combustion, single--pipe venting or ventilated combustion air. S Installation flexibility: sidewall or vertical vent. S Certified to leak 2% or less of nominal air conditioning CFM. A11300 delivered when pressurized to 1--in. water column with all The two--stage gas valve is at the heart of the comfort provided by present air inlets, air outlets, and condensate drain port(s) sealed. this furnace, along with the variable--speed ECM blower motor, and two--speed inducer motor.

3 With an Annual Fuel Utilization LIMITED WARRANTY*. Efficiency (AFUE) up to , the two--stage gas furnace S 20--year limited warranty on heat exchangers. provides exceptional savings as well when compared to standard S 10 year parts limited warranty to the original purchaser upon gas furnaces. This furnace also features 4--way multipoise timely registration. installation flexibility, and is available in six model sizes. The S Limited warranty period is five years for parts if not registered PG96 VAT can be vented for direct vent/two--pipe, ventilated combustion air, or single--pipe applications. All units meet within 90 days of installation.{. California Air Quality Management District emission requirements. * For owner occupied, residential applications.}

4 All sizes are design certified in Canada. {Jurisdictions where warranty benefits cannot be conditioned on registra- tion will receive registered limited warranty benefits. Always Ask For Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program. For CERTIFIED verification of certification for individual products, go to 1. CASING RATED HEATING OUTPUT{. HEATING. DIMENSIONS (IN.) (BTUH). COOLING MOTOR HP APPROX. SAP ORDERING NO. Rated CFM @ (VARIABLE SHIP WT. CFM CFM. High ESP SPEED) (LB). H D W High Low AFUE (Low (High Heating Heating) Heating). ESP. PG96 VAT30040AA 35 39,000 25,000 660 815 440 - 905 1/2 121. PG96 VAT42060BA 35 58,000 38,000 860 1135 435 - 1475 3/4 142. PG96 VAT48080BA 35 78,000 50,000 1160 1505 555 - 1610 3/4 152.}}

5 PG96 VAT60080CA 35 78,000 51,000 1200 1555 440 - 2005 1 156. PG96 VAT60100CA 35 97,000 63,000 1435 1865 405 - 2005 1 166. PG96 VAT66120DA 35 117,000 76,000 1675 2375 480 - 2115 1 190. {Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate. Minimum heat CFM when low---heat rise adjustment switch (SW 1 ---3) and comfort/efficiency adjustment switch (SW1 ---4) on control center are OFF. ESP --- External Static Pressure Dual Fuel System Compatibility This system can provide Direct or Single-pipe Venting, or Optional Ventilated more control over your monthly energy bills by automatically Combustion Air This furnace can be installed as a 2-pipe PG96 VAT. selecting the most economical method of heating.}

6 Our system (Direct Vent) furnace, in an optional ventilated combustion air automatically switches between the gas furnace and the electric application, or in single-pipe, non-direct vent applications. This heat pump as outside temperatures change to maintain greater provides added flexibility to meet diverse installation needs. efficiency and comfort than with any traditional single-source Sealed Combustion System This furnace brings in combustion heating system. The heat pump also delivers high-efficiency air from outside the furnace when installed as a direct vent or cooling in the summer. ventilated combustion air venting system, which results in Robust Igniter Payne's unique SiN igniter is not only especially quiet operation.

7 By sealing the entire combustion physically robust but it is also electrically robust. It is capable of vestibule, the entire furnace can be made quieter, not just the running at line voltage and does not require complex voltage burners. regulators as do other brands. This unique feature further enhances Monoport Burners The burners are specially designed and the gas furnace reliability and continues Payne's tradition of finely tuned for smooth, quiet combustion and economical technology leadership and innovation in providing a reliable and operation. durable Product . Bottom Closure Factory--installed for side return; easily Reliable Heat Exchanger Design The aluminized steel, removable for bottom return. The multi-use bottom closure can clamshell primary heat exchanger was reengineered to achieve also serve for roll-out protection in horizontal applications, and act greater efficiency out of a smaller size.

8 The first two passes of the as the bottom closure for the optional return air base accessory. heat exchanger are based on the current 80% Product , a design Blower Access Panel Switch Automatically shuts off 115-v with more than ten years of field-proven performance and success. power to furnace whenever blower access panel is opened. These innovations, paired with the continuation of a crimped, no-weld seam create an efficient, robust design for this essential Quality Registration Our furnaces are engineered and component. manufactured under an ISO 9001 registered quality system. The condensing heat exchanger, a stainless steel fin and tube Certifications This furnace is CSA (AGA and CGA) design design, is positioned in the furnace to extract additional heat.

9 Certified for use with natural and propane gases. The furnace is Stainless steel coupling box componentry between heat exchangers factory--shipped for use with natural gas. A CSA listed gas has exceptional corrosion resistance in both natural gas and conversion kit is required to convert furnace for use with propane propane applications. gas. The efficiency is GAMA efficiency rating certified. This furnace meets California Air Quality Management District 4-Way Multipoise Design One model for all applications emission requirements. there is no need to stock special downflow or horizontal models when one unit will do it all. The new heat exchanger design allows these units to achieve the certified AFUE in all positions. 2. SPECIFICATIONS.

10 Heating Capacity and Efficiency 30040 42060 48080 60080 60100 66120. Input High Heat (BTUH) 40,000 60,000 80,000 80,000 100,000 120,000. Low Heat (BTUH) 26,000 39,000 52,000 52,000 65,000 78,000. Output High Heat (BTUH) 39,000 58,000 78,000 78,000 97,000 117,000. Low Heat (BTUH) 25,000 38,000 50,000 51,000 63,000 76,000. Efficiency AFUE % (ICS) Certified Temperature 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70. High Heat Rise Range F ( C) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39). 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60. Low Heat (17 - 33) (17 - 33) (17 - 33) (17 - 33) (17 - 33) (17 - 33). Airflow Capacity and Blower data 30040 42060 48080 60080 60100 66120. Certified External Static Heating Pressure (in.)