Example: marketing

Product Data - dms.hvacpartners.com

48TC. Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons Product data C08613. the environmentally sound refrigerant TABLE OF CONTENTS. PAGE PAGE. FEATURES AND BENEFITS .. 3 APPLICATION data .. 31. MODEL NUMBER NOMENCLATURE .. 4 COOLING TABLES .. 34. FACTORY OPTIONS AND/OR accessories .. 6 STATIC PRESSURE ADDERS .. 55. AHRI COOLING RATING TABLES .. 9 FAN PERFORMANCE .. 59. HEAT RATING TABLE .. 10 ELECTRICAL INFORMATION .. 72. SOUND PERFORMANCE TABLE .. 11 SEQUENCE OF OPERATION .. 102. PHYSICAL data .. 13 GUIDE SPECIFICATIONS .. 105. CURBS & WEIGHTS DIMENSIONS .. 19. The Carrier rooftop unit (RTU) was designed by customers for customers. With no-- strip screw collars, handled access panels, and more we've made your unit easy to install, easy to maintain and easy to use. Easy to install: All WeatherMakerr units are field-- convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications.

5 Table 1 – FACTORY--INSTALLED OPTIONS AND FIELD--INSTALLED ACCESSORIES CATEGORY ITEM FACTORY INSTALLED OPTION FIELD INSTALLED ACCESSORY Cabinet Thru---the---base electrical or gas---line connections X X

Tags:

  Product, Data, Accessories, Product data

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Data - dms.hvacpartners.com

1 48TC. Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons Product data C08613. the environmentally sound refrigerant TABLE OF CONTENTS. PAGE PAGE. FEATURES AND BENEFITS .. 3 APPLICATION data .. 31. MODEL NUMBER NOMENCLATURE .. 4 COOLING TABLES .. 34. FACTORY OPTIONS AND/OR accessories .. 6 STATIC PRESSURE ADDERS .. 55. AHRI COOLING RATING TABLES .. 9 FAN PERFORMANCE .. 59. HEAT RATING TABLE .. 10 ELECTRICAL INFORMATION .. 72. SOUND PERFORMANCE TABLE .. 11 SEQUENCE OF OPERATION .. 102. PHYSICAL data .. 13 GUIDE SPECIFICATIONS .. 105. CURBS & WEIGHTS DIMENSIONS .. 19. The Carrier rooftop unit (RTU) was designed by customers for customers. With no-- strip screw collars, handled access panels, and more we've made your unit easy to install, easy to maintain and easy to use. Easy to install: All WeatherMakerr units are field-- convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications.

2 Lighter units make easy replacement. Most Carrier 48TC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. Easy to maintain: Easy access handles by Carrier provide quick and easy access to all normally serviced components. Our no-- strip screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit's metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s). Easy to use: The newly designed, central terminal board by Carrier puts all your connections and troubleshooting points in one convenient place, standard.

3 Most low voltage connections are made to the same board and make it easy to find what you're looking for and easy to access it. Carrier rooftops have high and low pressure switches, a filter drier, and 2-- in (51mm). filters standard. 2. FEATURES AND BENEFITS. S Single cooling stage models are available from 3 - 10 ton. S Two cooling stage models are available from - 15 ton. S SEER up to S EER's up to S IEER's up to with single speed indoor fan motor and up to with 2-- speed/VFD indoor fan motor. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 - ton units fit on existing Carrier rooftop curbs. This saves time and money on replacement jobs. S Standardized components and layout. Standardized components and controls make service and stocking parts easier.

4 S Scroll compressors on all units. This makes service, stocking parts, replacement, and troubleshooting easier. S Field convertible airflow (3 - 15 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 15 ton models require a simple supply duct cover to field convert from factory vertical to horizontal. S Easy-- adjust, belt-- drive motor available. S Provisions for bottom or side condensate drain. S Capable of thru-- the-- base or thru-- the-- curb gas line routing. S Single-- point gas / electrical connection. S Sloped, composite drain pan sheds water; and won't rust. S Standardized controls & control box layout. Standardized components & controls make stocking parts & service easier. S Tool-- less filter access door. S Clean, large, easy to use control box.

5 S Color-- coded wiring. S Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. S Single, central terminal board for test and wiring connections. S Fast-- access, handled, panels for easy access on normally accessed service panels. S No-- strip screw system guides screws into the panel & captures them tightly without stripping the screw, the panel, or the unit. S Mechanical cooling (115_F to 40_F or 46_C to 4_C) standard on all models. Winter Start Kit allows cooling operation down to 25_F (-- 4_C) and MotorMaster to - 20_F (-- 29_C). S High efficiency, gas heat with induced-- draft flue exhaust design. S Induced draft motor ensures no flue gas can escape into the indoor air stream. S Carrier designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically, manually drained.

6 This saves labor and maintenance expense. S 2-- in (51mm) disposable filters on all units. S Refrigerant filter-- drier on each circuit. S Each circuit is protected with a high and low pressure switch. S Many factory-- installed options ranging from air management economizers, 2 position dampers, plus convenience outlets, disconnect switches and smoke detectors. S Standard (parts only) Warranty: 10 yr. aluminized heat exchanger, 5 yr. compressor, 3 yr. Novation condenser coil, 1 yr. parts. S Factory-- installed Humidi-- MiZerr adaptive dehumidification system on all sizes with round tube / plate fin condenser coils, includes MotorMaster I controller. S Optional Staged Air Volume (SAV) system utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor fan motor speed between cooling stages. Available on 2-- stage cooling models 08-- 16 with electromechanical controls or RTU Open.

7 3. MODEL NUMBER NOMENCLATURE. 4 8 T C D A 0 4 A 1 A 5 --- 0 A 0 A 0. Unit Heat Type Packaging & Seismic 0 = Standard 48 = Gas heat pkg. rooftop 1 = LTL. 3 = CA seismic compliant Series Model 4 = LTL & CA seismic compliant TC = Standard Efficiency Heat Size Electrical Options D = Low heat A = None E = Med heat C = Non ---fused disconnect F = High heat D = Thru the base conn L = Low NOx, Low heat F = Non fused disc & thru the base M = Low NOx, Med heat G = 2 speed indoor fan (VFD) contr N = Low NOx, High heat J = 2 speed fan cntr (VFD) & non fused disc S = Stainless steel, Low heat K = 2 spd fan cntr (VFD) & thru the base conn R = Stainless steel, Med heat M = 2 speed fan (VFD) & non fused disc &. T = Stainless steel, High heat thru the base conn Refrigerant Systems Options Service Options A = Standard 1 stage cooling models 0 = None B = Standard 1 stg.

8 Cooling w/Humidi---MiZer 1 = Unpowered conveniece oulet (04 ---07 models only) 2 = Powered conveniece outlet D = 2 stage cooling models (08 ---16 models only) 3 = Hinged panels E = 2 stage cooling models w/ Al ---CU cond coil 4 = Hinged panels, unpowered & Humidi---MiZer (08 ---16 models only) 5 = Hinged panels, powered Cooling Tons 04 = 3 Ton 09 = Ton Intake / Exhaust Options 05 = 4 Ton 12 = 10 Ton A = None 06 = 5 Ton 14 = Ton B = Temp Economizer w/ barometric relief 07 = 6 Ton 16 = 15 Ton F = Enthalpy Econo w/ baro relief 08 = Ton K = 2 position damper U = Temp ultra low leak econo w/baro relief Sensor Options W = Enthalpy ultra low leak econo w/baro relief A = None B = RA smoke detector Base unit controls C = SA smoke Detector 0 = Base electromechanical controls D = RA + SA smoke detector 1 = PremierLink Controller E = CO2 sensor 2 = RTU open multi---protocol controller F = RA smoke detector & CO2 sensor 6 = Electromechanical with 2 speed fan & W7720 econo cntl.

9 G = SA smoke detector & CO2 sensor H = RA + SA smoke detector & CO2 sensor Design Revision Factory Assigned Indoor Fan Options 1 = Standard static option Voltage 2 = Medium static option 1 = 575/3/60 5 = 208 ---230/3/60. 3 = High static option 3 = 208 ---230/1/60 6 = 460/3/60. C = High Static option w/high efficiency motor (size 16 only). Coil Options for Round Tube/Plate Fin Cond Coil Models Only (outdoor--- indoor--- hailguard). A = Al/Cu --- Al/Cu M = Al/Cu --- Al/Cu --- Louvered hail guard Note: On single phase ( --- 3 voltage code) models, the following B = Precoat Al/Cu --- Al/Cu N = Precoat Al/Cu ---Al/Cu ---Louvered hail guard are not available as a factory installed option: C = Ecoat Al/Cu --- Al/Cu P = Ecoat Al/Cu --- Al/Cu --- Louvered hail guard --- Humidi---MiZer D=EcoatAl/Cu EcoatAl/Cu Q=Ecoat Al/Cu---Ecoat Al/Cu louvered hail guard --- Coated Coils or Cu Fin Coils E = Cu/Cu --- Al/Cu R = Cu/Cu --- Al/Cu --- Louvered hail guard --- Louvered Hail Guards F = Cu/Cu --- Cu/Cu S = Cu/Cu --- Cu/Cu --- Louvered hail guard --- Economizer or 2 Position Damper Coil Options for All Aluminum Novation Cond Coil Models Only --- Powered 115 Volt Convenience Outlet (outdoor--- indoor--- hailguard).

10 G = Al/Al --- Al/Cu T = Al/Al --- Al/Cu, louvered hail guard H = Al/Al --- Cu/Cu U = Al/Al --- Al/Cu, louvered hail guard J = Al/Al --- Ecoat Al/Cu V = Al/Al --- Ecoat Al/Cu, louvered hail guard K = Ecoat Al/Al --- Al/Cu W = Ecoat Al/Al --- Al/Cu, louvered hail guard L=Ecoat Al/Al---Ecoat Al/Cu X=Ecoat Al/Al --- Ecoat Al/Cu louvered hail guard Not all possible options can be displayed above --- see price pages or contact your Carrier Expert for more details. 4. Table 1 FACTORY-- INSTALLED OPTIONS AND FIELD-- INSTALLED accessories . FACTORY FIELD. CATEGORY ITEM INSTALLED INSTALLED. OPTION ACCESSORY. Thru ---the ---base electrical or gas---line connections X X. Supply Duct Cover (16 size only) X. Cabinet California Seismic Compliant Labeling X. Hinged Access Panels X. Cu/Cu indoor and/or outdoor coils1, 6 X. Coil Options Pre ---coated outdoor coils1, 6 X.