Example: bachelor of science

Product Data Sheet FOAMULAR 250 - idi-insulation.com

FOAMULAR 250 Rigid Foam InsulationProduct data Sheet Provides insulation in a metal or woodfurring system used for masonry orconcrete walls. Perform below grade in perimeter andfoundation applications, or directlybeneath the concrete slab to complementthe insulating sheathing envelope aroundthe building to common soils and decay,Owens Corning FORMULAR retains itsinsulating performance characteristics evenafter prolonged exposure to and Codes Compliance Recognized by code authorities underResearch Reports BOCA 91-54; ICBO 3628; SBCCI PST & ESI 9727 Meets HUD/FHA Use of MaterialsBulletin No. 71 and ASTM C 578-92 Type IV Underwriters Laboratories, Inc. Classification Certificate U-197 Thermal resistance: at 75 F, at 40 F mean temperature and 1" thickness (hr x ft2x F/Btu)All-purpose foam panelinsulation for masonry and other Corning FOAMULAR 250 extrudedpolystyrene insulation is ideal for wallfurring, perimeter/ foundation, cavity wall,crawlspace, pre-cast concrete, under slab,roofing systems

Product Data Sheet • Provides insulation in a metal or wood furring system used for masonry or concrete walls. • Perform below grade in perimeter and foundation applications, or directly beneath the concrete slab to complement the insulating sheathing envelope around the building framing.

Tags:

  Product, Sheet, Data, Product data sheet, Insulation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Data Sheet FOAMULAR 250 - idi-insulation.com

1 FOAMULAR 250 Rigid Foam InsulationProduct data Sheet Provides insulation in a metal or woodfurring system used for masonry orconcrete walls. Perform below grade in perimeter andfoundation applications, or directlybeneath the concrete slab to complementthe insulating sheathing envelope aroundthe building to common soils and decay,Owens Corning FORMULAR retains itsinsulating performance characteristics evenafter prolonged exposure to and Codes Compliance Recognized by code authorities underResearch Reports BOCA 91-54; ICBO 3628; SBCCI PST & ESI 9727 Meets HUD/FHA Use of MaterialsBulletin No. 71 and ASTM C 578-92 Type IV Underwriters Laboratories, Inc. Classification Certificate U-197 Thermal resistance: at 75 F, at 40 F mean temperature and 1" thickness (hr x ft2x F/Btu)All-purpose foam panelinsulation for masonry and other Corning FOAMULAR 250 extrudedpolystyrene insulation is ideal for wallfurring, perimeter/ foundation, cavity wall,crawlspace, pre-cast concrete, under slab,roofing systems, sheathing and otherapplications.

2 Owens Corning s patentedHydrovac process technology make theunique closed-cell structure of FOAMULAR insulation highly resistant to moisture,retaining it s initial R-value* year after year even following prolonged exposure towater leakage, humidity, condensation,ground water and freeze/ thaw 250 Performance Benefits High R-value (R-5 per inch of productthickness).* Compressive strength of 25 psi. Effective resistance against moisture,mildew, corrosion and rot. Ease of handling and installation(lightweight, tough, rigid foam panels). Easy to saw, cut and score Wide selection of sizes and thicknesses. Availability in straight, tongue andgroove, or scored square edges. Compliance with building codes 250 Superior insulation Performance for aWide Variety of Building RequirementsProduct ApplicationsHigh-performance FOAMULAR 250 works to: Retard the transmission of water vaporand moisture in masonry walls, helpingprevent structural Information FOAMULAR insulation is ideal for allbuildings under normal temperatureconditions, but should not be used incontact with chimneys, heater vents,steam pipes or other surfaces wheretemperatures exceed 150 F.

3 It is notrecommended for applications wheresustained temperatures exceed 165 F. All construction should be evaluated forthe necessity to provide vapor current ASHRAE Handbook ofFundamentals FOAMULAR insulation is a non-structural material and must be installed on framings which areindependently structurally adequate to meet required construction andservice loading conditions.*The higher the R-value, the greater the insulating power. Ask your seller for the fact Sheet on 250 Rigid Foam InsulationFOAMULAR Physical Properties(1) Product /ValuesASTMFOAMULARP ropertyMethod(2)250 Thermal conductivity k (3)[Btu x in/ft2x hr x F max]@ 75 F mean temperature @ 40 F mean strength,Minimum(specification) (lb/in2)(4)Flexural strength(lb/in2min)(5)C20375 Water absorption(%by volume max)(6) vapor permeance(perm max)(7) affinity hydrophobicWater capillarity noneDimensional stability(% linear change max)(8) coefficient of thermalexpansion (in/in/ F max) spread(9)(10)E845 Smoke developed(9)(10)(11)E8445-175 Oxygen index min(9)D286324(1)

4 Properties shown are representative values for 1" thick material based upon most recent productquality audit data . (2) Modified as required to meetASTM C578-92. (3) Thermal resistance (R) (hr. x F/Btu) of a 1" thickness at (at 75 Fmean temperature), (at 40 F). (4) Value at yield.(5) Value at yield or 5%, whichever occurs first. (6) data ranges from to value shown due to thelevel of precision of the test method. (7) Actual watervapor permeance data decreases as thicknessincreases. (8) data ranges from to value shown. (9) These laboratory tests are not intended to describethe hazard presented by this material under actual fireconditions. (10) data from Underwriters Laboratories,Inc.

5 Classified. See Classification Certificate U-197. (11) ASTM E84 is thickness-dependent, therefore arange of values is CORNING WORLD HEADQUARTERSONE OWENS CORNING PARKWAYTOLEDO, OHIO 43659 System Thinking and System Thinking Makes the Difference are trademarks of Owens color PINK is a registered trademark of Owens Corning. & designate names and products which are trademarks of Owens No. 5-FO-43522-A Printed in , October 2001 Copyright 2001 Owens CorningProduct DataFOAMULAR insulation Product 250 (25psi)(3)MaterialExtruded polystyrene closed-cellfoam panel with continuous skinson face and back surfacesWidth xThicknesses(1)(in)Length(2) (in)Edges1, 11 2, 2, 21 2, 316 x 96 Square3 4, 1, 11 2, 2, 21 2, 3, 31 2, 424 x 96 Square3 4, 1, 11 2, 2, 21 2, 348 x 96 Square1 2, 3 4, 148 x 108 SquareScored 3 4, 1, 11 2, 2, 21 2, 348 x 96 Square3 4, 1, 11 2, 224 x 96T&G(4)3 4, 1, 11 2, 248 x 96T&G(4)3 4, 148 x 108T&G(4)

6 Weight150 lb/1,000 ft2for 1" thickness PackagingShipped in units with two stretch-wrap bands per bundle, with anadditional exterior wrap(1) R per inch: (at 75 F mean temperature). (2) Other sizes available on request. Consult yourlocal Owens Corning representative for availability.(3) Compressive strength, minimum(specification)value (lb/in2). (4) Tongue-and-groove edge reducesair :All products described here may not be available in all geographic markets. Consult your local Owens Corning sales office or representative for Information: (800) 828-7155 Export Sales Office: (330) 633-1105 FOAMULAR insulation is produced byOwens Corning s patented HYDROVAC process more information on the Owens Corning family of home buildingproducts, contact your Owens Corningdealer, call 1-800-GET-PINKor access our Web Product will ignite if exposed to fire ofsufficient heat and intensity.

7 This productshould be installed only with a gypsumboard on the interior side of the shipping, storage, installation anduse, this Product should not be exposed to open flame or other ignition sources. NoteAll products described here may not be available in all geographic your local sales officerepresentative for more information.