Example: bachelor of science

Product Data Sheet: H-Series Hygienic Coriolis Flow and ...

Product data SheetPS-00599, Rev. NSeptember 2016 Micro Motion H-Series Hygienic Coriolis Flow and Density MetersHigh accuracy real world performance Best-in-class performance on liquid mass flow, volume flow and density measurements in a compact Hygienic design Superior sensitivity in a compact design to reduce variability in process control Rugged design minimizing process, mounting, and environmental effectsBest fit-for-application EHEDG certified, 3-A authorized, self-draining design for sanitary process control service Highly polished surface finish for ultra-pure fluids Broad range of I/O offerings including HART, Profibus-DP, FOUNDATION Fieldbus, DeviceNet, 4-20mA and Wireless capabilitiesExceptional reliability and safety Smart Meter Verification delivers complete, on-line verification of device health and performance, continuously or on-demand at the press of a button Low operating frequency for robust measurement in continuous two-phase flow and gas applications Reliable sensor design minimizes down time and process interruption costs(/,7(3 HDN SHUIRUPDQFH) 6 HULHV([FHSWLRQDO SHUIRUPDQFHFRPSDFW GUDLQDEOH+ 6 HULHV+\JLHQLFFRPSDFW GUDLQDEOH7 6 HULHV6 WUDLJKW WXEHIXOO ERUH5 6 HULHV*HQHUDO SXUSRVH IORZ DQG GHQVLW\/) 6 HULHV([WUHPHORZ Hygienic Flow and Density MetersSeptember 2016 M))]]

Product Data Sheet PS-00599, Rev. N September 2016 Micro Motion® H-Series Hygienic Coriolis Flow and Density Meters High accuracy real world performance Best-in-class performance on liquid mass flow, volume flow and density measurements in a

Tags:

  Sheet, Data, Data sheet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Data Sheet: H-Series Hygienic Coriolis Flow and ...

1 Product data SheetPS-00599, Rev. NSeptember 2016 Micro Motion H-Series Hygienic Coriolis Flow and Density MetersHigh accuracy real world performance Best-in-class performance on liquid mass flow, volume flow and density measurements in a compact Hygienic design Superior sensitivity in a compact design to reduce variability in process control Rugged design minimizing process, mounting, and environmental effectsBest fit-for-application EHEDG certified, 3-A authorized, self-draining design for sanitary process control service Highly polished surface finish for ultra-pure fluids Broad range of I/O offerings including HART, Profibus-DP, FOUNDATION Fieldbus, DeviceNet, 4-20mA and Wireless capabilitiesExceptional reliability and safety Smart Meter Verification delivers complete, on-line verification of device health and performance, continuously or on-demand at the press of a button Low operating frequency for robust measurement in continuous two-phase flow and gas applications Reliable sensor design minimizes down time and process interruption costs(/,7(3 HDN SHUIRUPDQFH) 6 HULHV([FHSWLRQDO SHUIRUPDQFHFRPSDFW GUDLQDEOH+ 6 HULHV+\JLHQLFFRPSDFW GUDLQDEOH7 6 HULHV6 WUDLJKW WXEHIXOO ERUH5 6 HULHV*HQHUDO SXUSRVH IORZ DQG GHQVLW\/))]

2 6 HULHV([WUHPHORZ Hygienic Flow and Density MetersSeptember 2016 Micro Motion H-Series Hygienic flow and density metersMicro Motion H-Series meters deliver superb measurement with exceptional flow and density performance as well as outstanding reliability in a compact Hygienic design for use in sanitary process control flow and density fit for Hygienic process control applications High performance rugged measurement in a compact self-draining design Low frequency, high sensitivity fit-and-forget meter provides robust measurements even under demanding process conditions Multiple line sizes provide an ideal platform for batching, distribution, allocation and intra-plant measurement applications Smart Meter Verification: advanced diagnostics for your entire system A comprehensive test that can be run locally or from the control room to provide confidence in your meter functionality and performance Verifies that your meter performs as well as the day it was installed, giving you assurance in less than 90 seconds Save significant expenditure by reducing labor and outsourced calibration service costs while eliminating process interruptionIndustry-leading capabilities that unleash your process potential Available with the most extensive offering of transmitter and mounting options for maximum compatibility with your system State of the art.)]

3 ISO/IEC 17025 compliant calibration stands achieving uncertainty drive best in class measurement accuracy The most robust communication protocol offering in the industry including Smart Wireless True multi-variable technology measures necessary flow and density process variables simultaneouslyWidest range of installation and process condition flexibility Featuring a low pressure drop, low weight design that reduces installation and commissioning costs Unmatched MVD transmitter technology with digital signal processing (DSP) delivers the fastest response rates enabling accurate batch and process measurement Design flexibility enables operation in SIP, CIP and sanitary where 3-A and EHEDG compliance is requiredContents Measurement principles .. 3 Performance specifications .. 4 Operating conditions: Environmental .. 7 Operating conditions: Process .. 8 Meter approvals and certifications.

4 9 Transmitter interface .. 10 Physical specifications .. 10 Ordering information .. 2016H-Series Hygienic Flow and Density MetersMeasurement principlesAs a practical application of the Coriolis effect, the Coriolis mass flow meter operating principle involves inducing a vibration of the flow tube through which the fluid passes. The vibration, though it is not completely circular, provides the rotating reference frame which gives rise to the Coriolis effect. While specific methods vary according to the design of the flow meter, sensors monitor and analyze changes in frequency, phase shift, and amplitude of the vibrating flow tubes. The changes observed represent the mass flow rate and density of the flow measurementThe measuring tubes are forced to oscillate producing a sine wave. At zero flow, the two tubes vibrate in phase with each other. When flow is introduced, the Coriolis forces cause the tubes to twist resulting in a phase shift.

5 The time difference between the waves is measured and is directly proportional to the mass flow measurementThe measuring tubes are vibrated at their natural frequency. A change in the mass of the fluid contained inside the tubes causes a corresponding change to the tube natural frequency. The frequency change of the tube is used to calculate measurementTemperature is a measured variable that is available as an output. The temperature is also used internal to the sensor to compensate for temperature influences on Young s Modulus of characteristics Measurement accuracy is a function of fluid mass flow rate independent of operating temperature, pressure, or composition. However, pressure drop through the sensor is dependent upon operating temperature, pressure, and fluid composition. Specifications and capabilities vary by model and certain models may have fewer available options.

6 Please refer to the Online Store Sizing and Selection Tool at the Micro Motion web site ( ) for detailed information regarding performance and capabilities. The letter at the end of the base mode code (for example, H100S) represents wetted part material S = 316L stainless steel 32 Ra finish ( m) and F = 316L stainless steel 15 Ra finish ( m).No flowWith flowOutlet pickoff displacementInlet pickoffdisplacementInlet pickoffdisplacementOutlet pickoff displacementTimeTimeTime Hygienic Flow and Density MetersSeptember 2016 Performance specificationsReference operating conditionsFor determining the performance capabilities of our meters, the following conditions were observed/used: Water at 68 to 77 F and to 29 psig (20 to 25 C and 1 to 2 barg) Accuracy based on industry leading accredited calibration stands according to ISO/IEC 17025 All models have a density range up to 3 g/cm3 (3000 kg/m3)Accuracy and repeatability on liquids and slurriesAccuracy and repeatability on gasesPerformance SpecificationsCalibration code ZCalibration code 1 Calibration code K (1) (2)Mass flow accuracy (3) of rate of rate of rateVolume flow accuracy (1) of rate of rate of rateMass flow repeatability of rateVolume flow repeatability of rate of rate of rate Density accuracy g/cm3 ( kg/m3) g/cm3 ( kg/m3) g/cm3 ( kg/m3)Density repeatability g/cm3 ( kg/m3) kg/m3 ( kg/m3) kg/m3 ( kg/m3)Temperature accuracy 1 C of readingTemperature repeatability C(1)

7 Only available with electronics code 0, 1, 2, 3, 4, 5, 6, 7, 8, 9.(2)Not available with model H025.(3)Stated flow accuracy includes the combined effects of repeatability, linearity, and specificationAll modelsMass flow accuracy (1) of rateMass flow repeatability (1) of rateTemperature accuracy 1 C of readingTemperature repeatability C(1) Stated flow accuracy includes the combined effects of repeatability, linearity, and 2016H-Series Hygienic Flow and Density MetersLiquid flow ratesNominal flow rateMicro Motion has adopted the term nominal flow rate, which is the flow rate at which water at reference conditions causes approximately psig (1 barg) of pressure drop across the flow rates for all modelsModelNominal line sizeNominal flow rateMaximum flow rateinchmmlb/minkg/hlb/minkg/hH0251/4 to 1/2 DN6 to DN135013361002,720H0501/2 to 1 DN13 to DN2515542263008,160H1001 to 2 DN25 to DN50604164401,20032,650H200F2 to 3 DN50 to DN801,91752,1602,35063,960H200S2 to 3 DN50 to DN801,91752,1603,20087,100H3003 to 4 DN80 to DN1005,298144,2009,995272,000 Volume flow rates for all modelsModelNominal flow rateMaximum flow rategal/minbarrels/hl/hgal/minbarrels/hl /hH025691,36612182,720H05019274,22636528 ,160H1007210316,44014420632,650H200F2303 2852,16038455087,100H200S23032852,160384 55087,100H300635907144,2001,2001,720272, Hygienic Flow and Density MetersSeptember 2016 Gas flow ratesWhen selecting sensors for gas applications, pressure drop through the sensor is dependent upon operating temperature, pressure.

8 And fluid composition. Therefore, when selecting a sensor for any particular gas application, it is highly recommended that each sensor be sized using the Online Store Sizing and Selection Tool at the Micro Motion web site ( ).The below table indicates flow rates that produce approximately 25psig ( ) pressure drop on natural stabilityZero stability is used when the flow rate approaches the low end of the flow range where the meter accuracy begins to deviate from the stated accuracy rating, as depicted in the turndown section below. When operating at flow rates where meter accuracy begins to deviate from the stated accuracy rating, accuracy is governed by the formula: accuracy = (zero stability/flow rate) x 100%. Repeatability is similarly affected by low flow capabilitiesThe graph and table below represent an example of the measurement characteristics under various flow conditions.

9 At flow rates requiring large turndowns (greater than 20:1), the zero stability values may begin to govern capability dependent upon flow conditions and meter in flow rates for all modelsModelMassVolumelb/minkg/hSCFMNm3/h H02517468388659H050521,4291,1832,010H100 2005,4524,5147,670H20066618,13715,01825, 515H3001,74547,50539,33466,829 Notes Standard (SCFM) reference conditions are psig and 60 F. Normal reference conditions are barg and 0 C. Natural gas with molecular weight of at 60 F (16 C) and psia (70 bara).Turndown from nominal flow rate40:115:12:1 Accuracy % droppsig (barg) ( ) ( ) ( )Flow rate, % of nominalAccuracy, % :120:11:12 2016H-Series Hygienic Flow and Density MetersProcess pressure ratingsSensor maximum working pressure reflects the highest possible pressure rating for a given sensor. Process connection type and environmental and process fluid temperatures may reduce the maximum rating.

10 Refer to the Technical data sheet for common sensor and fitting sensors comply with ASME process piping code and Council Directive 97/23/EC of 29 May 1997 on pressure pressureOperating conditions: EnvironmentalVibration limitsMeets IEC , endurance sweep, 5 to 2000 Hz, 50 sweep cycles at limitsSensors can be used in the process and ambient temperature ranges shown in the temperature limit graphs. For the purposes of selecting electronics options, temperature limit graphs should be used only as a general guide. If your process conditions are close to the gray area, consult with your Micro Motion stability for all modelsModelZero stabilitylb/ maximum working pressure for all modelsModelpsigbargH025F, H050F, H100F, H200F, H300F1,01570H025S, H050S, H100S, H200S, H300S1,450100 Case pressure for all modelsModelCase maximum pressureNAMUR NE132 Typical burst pressurepsigbargpsigbargpsigbargH0251661 11,256871,884130H05013591,020701,530105H 1001097854591,28188H2006445073576052H300 256171,7541202, Hygienic Flow and Density MetersSeptember 2016 Ambient and process temperature limits for all H-Series metersOperating conditions: ProcessProcess temperature effect For mass flow measurement, process temperature effect is defined as the change in sensor flow accuracy due to process temperature change away from the calibration temperature.