Example: barber

Product Data Sheet: Rosemount 702 Wireless Discrete ...

Product data Sheet00813-0100-4702, Rev LAAugust 2020 Rosemount 702 Wireless DiscreteTransmitter An installation-ready solution that provides dual channel, Discrete input, Discrete output, or leak detection input options. Discrete single or dual switch input with logic for limit contact and opposing contact applications. Momentary inputs are continuously measured between Wireless updates. Dual channels are each configurable for Discrete input or Discrete output. Self-organizing network delivers information rich data with >99 percent data Wireless SolutionIEC 62591 (WirelessHART ) .. the industry standardSelf-organizing, adaptive mesh routing Backed by Emerson s proven experience inWireless field instrumentation and experttechnical support. The self-organizing, self-healing network managesmultiple communication paths for any givendevice.

Product Data Sheet 00813-0100-4702, Rev LA ... SS04 Universal safety shower/eyewash kit for insulated pipe with CSA switches ★ ... The power module is an Intrinsically Safe solution, containing Lithium-thionyl chloride with a polybutadine terephthalate (PBT) enclosure.

Tags:

  Sheet, Data, Safety, Data sheet, Chloride, Thionyl chloride, Thionyl

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Data Sheet: Rosemount 702 Wireless Discrete ...

1 Product data Sheet00813-0100-4702, Rev LAAugust 2020 Rosemount 702 Wireless DiscreteTransmitter An installation-ready solution that provides dual channel, Discrete input, Discrete output, or leak detection input options. Discrete single or dual switch input with logic for limit contact and opposing contact applications. Momentary inputs are continuously measured between Wireless updates. Dual channels are each configurable for Discrete input or Discrete output. Self-organizing network delivers information rich data with >99 percent data Wireless SolutionIEC 62591 (WirelessHART ) .. the industry standardSelf-organizing, adaptive mesh routing Backed by Emerson s proven experience inWireless field instrumentation and experttechnical support. The self-organizing, self-healing network managesmultiple communication paths for any givendevice.

2 If an obstruction is introduced into thenetwork, data will continue to flow because thedevice has other established Wireless architecture Standard IEEE radios GHz ISM band sliced into 15 radio-channels Time-synchronized channel hopping Direct sequence spread spectrum (DSSS)technology delivers high reliability in challengingradio environmentEmerson's Wireless Seamless integration to all existing host systems Native integration into DeltaV and Ovation is transparent and seamless Gateways interface with existing host systems using industry standard protocols including OPC, Modbus TCP/IP, ModbusRTU, and EtherNet/IP Layered security keeps your network safe Ensures data transmissions are received only by the Wireless Gateway. Network devices implement industry standard Encryption, Authentication, Verification, Anti-Jamming, and Key Management.

3 Third party security verification including Achilles and FIPS197, with password strength monitoring, user-based log in,password reset requirements, automatic lockout, password expiration Wireless 2 Ordering shower and eye wash 702 August information CONFIGURE > VIEW Product >Online Product ConfiguratorMany products are configurable online using our Product Configurator. Select the Configure button or visit our website to this tool's built-in logic and continuous validation, you can configure your products more quickly and and optionsSee the Specifications and options section for more details on each configuration. Specification and selection of Product materials,options, or components must be made by the purchaser of the equipment. See the Material selection section for more code exampleModel codes contain the details related to each Product .

4 Exact model codes will vary; an example of a typical model code is shownin Figure 1: Model Code ExampleXXX X XXX X X XX XXX XXX XX121. Required model components (choices available on most)2. Additional options (variety of features and functions that may be added to products)Required model componentsModelCodeDescription702 Discrete transmitter Transmitter typeCodeDescriptionDWireless field mount OutputCodeDescriptionXWireless August 2020 Rosemount dual input (dry contact), detects momentary inputs and counts 42 Discrete dual input or output, configurable 52 Plunger arrival detection (for use with ETC Cyclops Plunger Arrival Sensor) 61(1)Liquid hydrocarbon detection (for use with TraceTek sensing cable) (1)LCD display not available for option code compartment housing aluminum EDual compartment housing SST Conduit threadsCodeDescription1 14 NPT CertificationCodeDescriptionMeasurement option intrinsically safe, Non-incendive, and Dust ignition- proof32, 52, 61 I6 Canada intrinsically safe32, 52, 61 I1 ATEX intrinsically safe32, 52, 61 IUATEX intrinsically safe for zone 232, 42, 52 I7 IECEx intrinsically safe32, 52, 61 IYIECEx intrinsically safe for zone 232, 42, 52 I4 TIIS intrinsically safe32, 42, 52 I3 China intrinsically safety32 division 2, Non-incendive32, 42, 52 N6 Canada division 2, Non-incendive32, 42, 52 I2 INMETRO Intrinsically Safe32, 52 IZINMETRO Intrinsically Safe for Zone 242 KQUSA, Canada.

5 ATEX Intrinsic safety Combination32 IMTechnical Regulations Customs Union (EAC) Intrinsic Safety32 NMATEX Intrinsic safety for Mining32, 52 IPKorea Intrinsically Safe61 NANo approval32, 42, 52, 61 Rosemount 702 August optionsWireless update rate, operating frequency and protocolCodeDescriptionWA3 User configurable update rate, GHz DSSS, IEC 62591 (WirelessHART ) Omni-directional Wireless antenna and SmartPower SolutionsBlack power module must be shipped separately, order Model antenna, adapter for black power module ( Power module sold separately) WM1 Extended range, external antenna, adapter for black power module ( Power module sold separately) WJ1 Remote antenna, adapter for black power module ( Power module sold separately)WN1(1)High-gain, remote antenna, adapter for black power module ( Power module sold separately)(1)Limited availability, consult factory for 2020 Rosemount optionsExtended Product warrantyCodeDescriptionWR33-year limited warranty WR55-year limited warranty DisplayLCD display not available for option code display Mounting bracketCodeDescriptionB4 Universal L mounting bracket for two inch pipe mounting SST bracket and bolts ConfigurationCodeDescriptionC1 Factory configure date, descriptor, message fields, and Wireless parameters Cable glandCodeDescriptionG2 Cable gland ( mm) G4(1)Thin wire cable gland (3 8 mm) (1)

6 Thin wire cable gland is preferred for measurement option and kitsCodeDescriptionSS01 Universal safety shower/eyewash kit with UL switches SS02 Universal safety shower/eyewash kit for insulated pipe with UL switches SS03 Universal safety shower/eyewash kit with CSA switches SS04 Universal safety shower/eyewash kit for insulated pipe with CSA switches Rosemount 702 August Parts and AccessoriesPart numberDescription00702-9010-0001 Universal safety shower/eyewash kit with UL switches00702-9010-0002 Universal safety shower/eyewash kit for insulated pipe with UL switches00702-9010-0003 Universal safety shower/eyewash kit with CSA switches00702-9010-0004 Universal safety shower/eyewash kit for insulated pipe with CSA switches03151-9270-0003 Mounting Bracket Kit, SSTA ugust 2020 Rosemount specificationsDiscrete inputSingle or dual SPST dry contacts, single SPDT dry contacts or leak detection.

7 To maintain ratings, contacts must be limited tosimple switches or leak detection threshold, measurement option code 32 and 42 Open > 100 K OhmClosed < 5 K OhmMomentary Discrete input, measurement option code 32 and 42 Detects momentary Discrete inputs of 10 millisecond or more duration. At each Wireless update, device reports current discretestate and accumulating count of close-open cycles. Accumulating count registers from 0 to 999,999, then re-sets to output, measurement option Code 42 Maximum rating: 26 Vdc, 100 mAOn resistance: typical 1 OhmWireless outputIEC 62591 (WirelessHART ) GHz DSSSR adio frequency power output from antennaExternal (WK option) antenna: Maximum of 10 mW (10 dBm) EIRPE xtended range, external (WM option) antenna: Maximum of 18 mW ( dBm) EIRPR emote (WJ option) antenna: Maximum of 17 mW ( dBm) EIRPHigh-gain, remote (WN option) antenna: Maximum of 40 mW (16 dBm) EIRPL ocal displayThe optional integral LCD display can show Discrete state and diagnostic information.

8 Display updates at each Wireless option for a local display is not available with option 61, Liquid hydrocarbon leak conditions are 70 F (21 C), and routing data for three additional network limits0 100 percent relative humidityWireless update rate, measurement option code 32, 42, 52 User selectable, 1 second to 60 minutesRosemount 702 August update rate, measurement option code 61 User selectable, four seconds to 60 minutesWireless latching time, measurement option code 52 User selectable, 1 second to 10 minutePhysical specificationsMaterial selectionEmerson provides a variety of Rosemount products with various Product options and configurations including materials ofconstruction that can be expected to perform well in a wide range of applications. The Rosemount Product information presentedis intended as a guide for the purchaser to make an appropriate selection for the application.

9 It is the purchaser s sole responsibilityto make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives,contaminants, etc.), when specifying Product , materials, options, and components for the particular application. Emerson is not ina position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the Product , options,configuration or materials of construction connectionsPower ModuleThe Emerson SmartPower Power Module is field replaceable, featuring keyed connections that eliminate the risk of power module is an Intrinsically Safe solution, containing Lithium- thionyl chloride with a polybutadine terephthalate (PBT) transmitter has power module life time rating of 10 years with a one-minute update rate, at reference conditions are 70 F (21 C) and routing data for three additional network exposure to ambient temperature limits ( 40 or 185 F.)

10 40 or 85 C) may reduce specified life by up to 20 terminalsScrew terminals permanently fixed to terminal blockField Communicator terminal connectionsClips permanently fixed to terminal block, designated by the text COMM. Materials of constructionEnclosureHousing:low-copper aluminum, or stainless steelPaint:PolyurethaneCover O-ring:Buna-NTerminal andpower modulepackPBTA ntennaPBT/PC integrated omni-directional antennaAugust 2020 Rosemount entries 14 NPTW eightLow-copper aluminumRosemount 702 without LCD display - lb. ( kg) Rosemount 702 with M5 LCD display - lb. ( kg)Stainless steelRosemount 702 without LCD display - lb. ( kg) Rosemount 702 with M5 LCD display - lb. ( kg)Enclosure ratings (702)NEMA 4X and IP66/67 MountingTransmitters may be attached directly to switch, brackets also permit remote mounting.