Transcription of Programmable Limit Alarm Trips SPA SYI User’s …
1 SYID emand Moore ReliabilityAll product names are registered trademarks of their respective s ManualSPA2No. 224-790-00 KMay 2018 Programmable Limit Alarm Industries-International, 2 - user s Manual224-790-00 KMay 2018 Customer SupportMoore Industries is recognized as the industry leader in delivering top quality to its customers in products and services. We perform a sequence of stringent quality assurance checks on every unit we ship. If any Moore Industries product fails to perform up to rated specifications, call us for help. Our highly skilled staff of trained technicians and engineers pride themselves on their ability to provide timely, accurate, and practical answers to your process instrumentation questions. Our headquarters and other facilities phone numbers are listed below. There are several pieces of information that can be gathered before you call the factory that will help our staff get the answers you need in the shortest time possible.
2 For fastest service, gather the complete model and serial number(s) of the problem unit(s) and the job number of the original Moore ReliabilityLocationsWorld HeadquartersEuropeAustralia16650 Schoenborn StreetNorth Hills, California91343-6196, : (818) 894-7111 Fax: (818) 891-2816E-mail: FREE: 1 Lloyds Court, Manor Royal, CrawleyW. Sussex RH10-9 QUUnited KingdomTel: 01293 514488 Fax: 01293 536852 FREE PHONE: 0800 NSW3/1 Resolution DriveCaringbah, New South Wales 2229 AustraliaTel: (02) 8536-7200 Fax: (02) Gezellestraat 106 BE-2630 AartselaarBelgiumTel: 03 : : , WA6/46 Angove StreetNorth Perth, Western Australia 6006 AustraliaTel: (08) 9228-4435 Fax: (08) 102, No. 101, Lane 1058, Xinzhen Street, Xinqiao Town, Songjiang District,Shanghai, 201612, P. R. ChinaTel: 86-21 62491499 Fax: 86-21 62490635E-mail: Meslaan 984003 CD TielThe NetherlandsTel: (0)344-617971 Fax: Limit Alarm TripsS PA2 Customer Industries-International, 3 - user s Manual224-790-00 KMay 2018 Safety Messages Please read this manual in its entirety.
3 It should answer most of your questions. For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining this product. Should you still have questions please visit our web site at or contact any of our sales/support offices nearest you. Your safety and the safety of others is very important. We have provided many important safety messages in this manual. Please read these messages carefully. These safety messages alert you to potential hazards that could hurt you or others or render damage to units. All Moore Industries instrumentation should only be used for the purpose and in the manner described in this manual. If you use this product in a manner other than that for which it was intended, unpredictable behavior could ensue with possible hazardous consequences.
4 Each safety message is associated with a safety alert symbol. These symbols are found in the throughout the manual. The definition of these symbols is described below: Pay particular attention wherever you see the following symbols:Note Information that is helpful for a procedure, condition or operation of the Hazardous procedure or condition that could damage or destroy the Hazardous procedure or condition that could injure the Personnel The Moore Industries product/systems described in this manual may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these Moore Industries use of Moore Industries products Moore Industries products may only be used for the applications described in the catalog and in the relevant technical documentation.
5 If products and components from other manufacturers are used, these must be recommended or approved by Moore Industries . Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be have reviewed the contents of this publication to ensure consistency with the hardware and/or software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Specifications and information are subject to change without product and company names are trademarks or registered trademarks of their respective holders.
6 Use of them does not imply any affiliation with or endorsement by them unless otherwise Limit Alarm TripsS PA2 About this Industries-International, 4 - user s Manual224-790-00 KMay 2018 Table of ContentsProgrammable Limit Alarm TripsS PA2 Section 1 - Introduction 8 Overview ..8 Model Numbers and Options ..8 Inputs ..8 Outputs ..9 Power ..9 Options ..9 Housing ..9 Internal Settings ..9 Alarm Terminology ..10 Section 2 - Calibration and Bench Check 14 Calibration ..14 Bench Check Procedure ..15 Units with the Analog Output Option (-AO) ..17 Section 3 - Installation and Wiring 18 Mounting ..18CE Certification-related Guidelines ..23 Contact/Load Suppression ..23 Installation in Hazardous Locations ..23 Special Conditions of Use ..23 Section 4: Configuration Front Panel Pushbuttons 24 Main Menu/View Settings ..25 Configuring the HLPRG Input ..29 Configuring the TPRG Sensor.
7 30 Configuring the Options ..32 Scaling the Input ..35 Applying Input (Bench Scaling) ..37 Input Trimming ..38 Configuring the Analog Output (-AO Option) ..40 Scaling the Analog Output (-AO Option) ..41 Trimming the Analog Output (-AO Option) ..42 Configuring the Alarm (s) ..45 Password Configuration .. Industries-International, 5 - user s Manual224-790-00 KMay 2018 Programmable Limit Alarm TripsS PA2 CONTENTSS ystem Information Menu ..58 Section 5: SPA2 PC Configuration Software 59 Installing the Configuration Software ..59 Connecting the SPA2 to the PC ..59 Selecting Model Type ..60PC Configuration Software Summary ..62 Status and Tool Bar Legend ..63 Configuration Screens ..64 Input ..64 Alarms ..67 Analog Output ..71 Scaling ..75 Custom Curve ..76 Section 6: Operation and Maintenance 78 Operation ..78 Maintenance ..78 Section 7: Specifications 80 SPA2 HLPRG Specifications.
8 80 SPA2 TPRG Specifications ..82 Section 8: Ordering Information 85 Ordering Information ..85 Warranty Disclaimer Industries-International, 6 - user s Manual224-790-00 KMay 2018 Programmable Limit Alarm TripsS PA2 SECTION 1 ENTERPASSE nter the password code to enablesettings changes.(Default = 55)Scale Input "Smart Scaling":Set the values to be displayedat zero and full scale withoutcalibration Analog Output:Connect the SPA2 into a calibrationset-up as shown in the manual andtrim the analog output.(Requires -AO Option)Configure Input:Select volt or current to :View or change Input (Bench Scaling):Using calibration equipment,capture the zero and full Information:View information such asserial number, Firmware Version,Hardware Version, Input Model,and Output ModelConfigure Options:Set engineering units, decimal places, 50/60Hz filter, broken wire detection and Jumperinstalled in OFF Jumperinstalled in ON PanelPushbuttonsUse the UP and DOWN pushbuttonsto scroll through menus and the SELECT pushbutton to access menus and/or make a Alarm :Configure Alarm types & Input:Match the actual reading of your SPA2 to a calibrated or known Analog Output:Connect the SPA2 into a calibrationset-up as shown in the manualand scale the analog output.
9 (Requires -AO Option)SCALEAOUTSELECTDOWNUPDDDDDDDDDDUU UUUUUUUUExit Configuration Menu:Return to process Analog Output:Choose damping value and fail mode.(Requires -AO Option)S PA2 HLPRG Quickstart Guide Use the front push-buttons to quickly and easily setup the SPA2 for your application. After programming your Alarm using the diagram below, install the unit into your application using the connection diagram and terminal designation table located in this Configuration The following are the default factory settings for your mA, 4-20mADisplay Normal Mode, PV60Hz FilterBroken wire enabled, level set to Average Filter set to 4 All alarms set to Trip High at 12mA with Deadband set to 0 All alarms range set to 4-20mAAll alarms have OOR & Input Failure disabledAll alarms are configured as Fail Safe, latching disabled, 0 delayAO (if fitted) : Current 4-20mA, fail high, hold duration of 1 Industries-International, 7 - user s Manual224-790-00 KMay 2018 Programmable Limit Alarm TripsS PA2 SECTION 1S PA2 TPRG Quickstart Guide Use the front pushbuttons to quickly and easily set-up the SPA2 for your application.
10 After programming your Alarm using the diagram below, install the unit into your application using the connection diagrams and terminal designation table located in this PanelPushbuttonsUse the UP and DOWN pushbuttons to scroll through menus and sub-menus. Use the SELECT pushbutton to access menus and/or make a im Analog Output:Connect the SPA2 into a calibrationset-up as shown in the manual andtrim the analog output.(Requires -AO Option)Password:View or change Options:Display mode, decimal places,50/60Hz filter, start delay, display test and factory Input:Using calibration equipment,capture the zero and full scalev Configuration Menu:Return to process Analog Output:Set the values for output atzero and full input(Requires -AO Option)DUDCONFGAOUTC onfigure Analog Output:Choose damping valueand fail mode.(Requires -AO Option)TRIMINPUTTr im Input:Match the actual reading of yourSPA2 to a calibrated or the password code to enablesettings changes.