1 Product Data SheetEdition 06, 2003 Identification no. GF01 SikaGrout 215 Sikagrout 215 Pumpable Non-Shrink Cementitious GroutDescriptionSika Grout 215 if a Non-Shrink self levelling, Cementitious grouting mortar withextended working time to suit local ambient Grout 215 is suitable for repairs to concrete structures and the followinggrouting works with clearance of 10mm or more:n Machine foundationsn Rail bedsn Columns in pre-cast constructionn Concrete anchorsn Bridge bearingsn Cavitiesn Gapsn RecessesCharacteristics /Advantagesn Highly early strengthn High ultimate stregthn Extended working timen Dense, non-shrinkn Non-toxic, non-corrosiven Chloride and iron freen High final strength1 SikaGrout -215 1/2 Instruction for UseSurface PreparationSurface PreparationConcrete surfaces should be clean, sound and free from oil, grease, cementlaitance and all loosely adhering particles.
2 Metal surfaces (iron and steel) should be free from scale, rust, oil and grease. Absorbent substrates must be saturatedthoroughly, but there should be no standing pre-mixed powder is added to water to suit the desired consistency. For flowable consistency, approximately litres of water per bag is required. Mix mechanically for 2-3 mins with a slow speed drill (max. 500 RPM) until a smooth even consistency is mixing., allow the mortar to rest for a while, stirring lightly to ensure that airdisplayed by the grouting is allowed to escape.
3 When carrying out base plate grouting, ensure that sufficient pressure head is maintained to keep mortar flow uninterrupted. Make sure that the necessary formwork is firmly in place and kept water light. Sika Grout 215 may be placed in thickness up to a maximum of 50mm at one large areas are to be placed, it is important to maintain a continuous flow throughout. It is necessary to organize the work sequence properly (manpower, materials, etc.) to ensure an uninterrupted flow. In such large areas, Sika Grout 215 may also be pumped. A heavy duty diaphragm pump is recommended for this purpose.
4 Screw feed and piston pumps may also be used. Specific ApplicationGrouting under base plate: Use flowable consistencyGrouting Anchor bolts: Use trowellable consistencyGrouting large volumes: For sections thicker than 50mm it is necessary to fillthe Sika Grout 215 with graded 10mm silt free aggregate to minimize temperaturerise. The quantity of aggregate should not exceed 1 part Sika Grout 215 by such mixes, a conventional concrete mixer and pump may be all tools and equipment with water immediately after use. Hardened mortarcan only be mechanically RecommendationsUse Sika Grout 215 for repairs to concrete structure and grouting only.
5 Minimum Gap: 10mmMaximum Gap: 50mmMinimum Application Temperature: 10 0 CAt temperature lower than 20 0C setting time and stregnth gain will be exposed mortar surface for at least 3 days with Anitsol E curing compoundor use other approved curing (approx.)Sika Grout Water (Litre) Volume kg 1 kg x 25 kg bag 309 1 m3 PerformanceFlow (British Standard Cone):280 - 320 mm after 3 minutes260 - 300 mm after 30 minutes(Keep on stirring slightly)Comprehensive Strength in MPa (N/mm2):(Water content: liters/25 kg bag. Testing & storge at 25 0 C under water)1 day : 383 days : 457 days : 5528 days : 70 Technical DataColorGreyFormPowderBulk kg/lWet - kg/lStorage ConditionStore in a dry placeShelf Life15 months when unopenedThe information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika s current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations.
6 In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed.
7 All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on NoticeSika Philippines, A & B888 Marcos Alvarez, , Las Pi as City : 800 1818 Fax. no : 806 -215 2/2 Constructio