Acrylic Sealant - 4 Hour Fire RatedProduct Data SheetPyroplex Limited, The Furlong, Droitwich, Worcestershire WR9 9BG, UKTel: +44 (0)1905 795432 Fax: +44(0)1905 791878 Email: Web: Intumescent Acrylic Sealant is a one part, highmodulus, halogen free product. It is suitable forperimeter pointing around doors and windows andsealing small openings and pipe penetrations whichhave been protected by the recommended Pyroplex Intumescent product. It is also ideal for sealing aroundtrunking and steel Intumescent Acrylic Sealant is fire rated up to4 hours and offers excellent adhesion to many commonbuilding substrates and is also fully Intumescent Acrylic Sealant is tested toBS EN1366: Part 4: 2006 and other InternationalStandards including of ApplicationPyroplex Intumescent Acrylic Sealant ha

AcrylicSealant-4HourFireRated 8.InstallationInstructions(cont’d.) Sealantadheringtoporoussurfacesshouldbeleftjustuntil ...

Tags:

  Sealant, Installationinstructions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Pyroplex Acrylic Sealant - Firepipe Supply

1 Acrylic Sealant - 4 Hour Fire RatedProduct Data SheetPyroplex Limited, The Furlong, Droitwich, Worcestershire WR9 9BG, UKTel: +44 (0)1905 795432 Fax: +44(0)1905 791878 Email: Web: Intumescent Acrylic Sealant is a one part, highmodulus, halogen free product. It is suitable forperimeter pointing around doors and windows andsealing small openings and pipe penetrations whichhave been protected by the recommended Pyroplex Intumescent product. It is also ideal for sealing aroundtrunking and steel Intumescent Acrylic Sealant is fire rated up to4 hours and offers excellent adhesion to many commonbuilding substrates and is also fully Intumescent Acrylic Sealant is tested toBS EN1366: Part 4: 2006 and other InternationalStandards including of ApplicationPyroplex Intumescent Acrylic Sealant has been specificallydesigned for use when: Sealing linear gap joint seals.

2 Sealing small openings in fire walls and floors. Sealing around plastic pipe or cable penetrations which havebeen protected with the recommended Pyroplex Intumescent product eg. pipe collar, pipe wrap, linear gap seal. Sealing around trunking and steel Features Fire rating up to 4 hours. Excellent adhesion to many common building substrates. Joint movement accommodation +/-15%. Expands by approximately 15% in fire conditions. Fully paintable. Available in white. Other colours also available subject to aminimum order DataApplication:Linear Gap Joint - Movement JointsFire Resistance Period:240 minutesInsulation/Integrity:Insulation and IntegrityTest Standard:BS EN1366: Part 4: 2006 Page:1 of 2 QUICKVIEWP roduct PackagingPyroplex Intumescent Acrylic is supplied in 310ml cartridges per box complete with 25 have carried out numerous independent fireresistance tests to confirm the suitability of the product and todemonstrate product compliance by utilising BS EN1366: Part 4.

3 2006 and other international standards including BS476. WFReport No. 166576A is available upon InstructionsEnsure that all the surfaces are clean, dry, sound and free frost(external application) clean all joints thoroughly to ensure thatthe adhesion of the silicone to the substrate is not may be necessary to mask adjacent areas to preventcontamination and to ensure a neat Sealant line. Masking tapesshould be immediately removed after tooling and backing materials as required and commence to fill thecavity or void with joint should be tooled within 5 minutes of the applicationto ensure good a contact between the silicone and of the Sealant also gives a smooth and material should be cleaned off non-porous surfacesusing a suitable solvent.

4 Sealant on porous surfaces should beleft until cured and excess removed by mechanical of spent cartridges in accordance with local and Safety InformationFor detailed information on this product please refer to therelevant Material Safety Data regulations apply for the transport of this material. Notclassified as hazardous for road, rail, sea or air MaterialsPEPolyethylene, with a nominal density of wool, with a nominal density of 100 mins71 minsB30mm20mmDoubleMW240 mins240 minsC10mm10mmSinglePE240 mins180 minsD10mm10mmDoubleMW240 mins240 minsI20mm20mmSinglePE240 mins90 minsK20mm10mmDoubleMW240 mins240 minsAcrylic Sealant - 4 Hour Fire RatedProduct Data SheetStorage ConditionsStore dry and in a cool place (not above 35 C)

5 And ensuresufficient GuaranteeProviding the product is installed in accordance with therequirements of the guidance document the fire performancecharacteristics of the product is guaranteed for a period of ApprovalPyroplex Limited has a Quality Management System thatmeets the requirements of BS EN ISO 9001:2000, and isindependently verified under Certificate Support and GuidanceShould you require any further information please contactPyroplex Limited or visit our website, InformationThe information contained herein is based upon the presentstate of our knowledge.

6 Recipients of our Pyroplex productsmust take responsibility for observing existing laws to our policy of continuous improvement Pyroplex Limited reserves the right to amend specifications without Limited, The Furlong, Droitwich, Worcestershire WR9 9BG, UKTel: +44 (0)1905 795432 Fax: +44(0)1905 791878 Email: Web: :Linear Gap Joint - Movement JointsFire Resistance Period:240 minutesInsulation/Integrity:Insulation and IntegrityTest Standard:BS EN1366: Part 4: 2006 Page:2 of 2 QUICKVIEW6. Structural ApplicationsPyroplex Acrylic can be used in wall and floors, of a.

7 Aerated concrete, lightweight ash blocks and/or solid Consumption GuideLinear metres per 310ml cartridge, the figures quoted estimatedand for guidance Installation InstructionsEnsure that all the surfaces are clean, dry, sound and free frost(external application) clean all joints thoroughly to ensure thatthe adhesion of the Acrylic to the substrate is not may be necessary to mask adjacent areas to preventcontamination and to ensure a neat Sealant line. Masking tapesshould be immediately removed after tooling and backing materials as required and commence to fill thecavity or void with joint should be immediately within 5 minutes of theapplication to ensure good a contact between the Acrylic andsubstrate.

8 Tooling of the Acrylic also gives a smooth andprofessional Acrylic should be cleaned off and non-porous surfaceswhilst in an uncured state using a suitable Sealant - 4 Hour Fire RatedPyroplex Limited, The Furlong, Droitwich, Worcestershire WR9 9BG, UKTel: +44 (0)1905 795432 Fax: +44(0)1905 791878 Email: Web: Field of ApplicationPyroplex fire rated intumescent Acrylic Sealant is a one part,low-modulus, neutral cure and halogen free product. Ideal forsealing joints to prevent the passage of flammable gases andtoxic smoke in compartment walls and floors.

9 Sealing of pipeand cable penetrations in fire rated Advantages Excellent movement accommodation +/-15% Excellent adhesion to porous and non-porous constructionsubstrates Non-slump Expands approximately 15% in a fire situation Excellent weathering resistance Long service life no maintenance required Internal applications3. Joint ConfigurationsThe fire resistance performance of the material is based uponthe joint configuration and the position and location of the seal,within the construction and backing materials Pyroplex Test ReportsA number of independent fire resistance tests have been carriedout to confirm the suitability of the product and to demonstrateproduct compliance by utilising BS476: Part 20, BS EN1366: Part4: 2006 and other international Data SheetIssue Date:1st October 2007 Issue of Pages2 Page of 2 Application.

10 Linear Gap Joint - Movement JointsFire Resistance Period:240 minutesInsulation/Integrity:Insulation and IntegrityTest Standard:BS EN1366: Part 4: 2006 QUICKVIEWC onstuctionElementFire ResistancePeriod (mm)MinimumThickness(mm)MaterialTypes andMinimum DensityWall and FloorUp to 120minutes100 Solid masonry work*, witha density no les than650kg/m3 Wall and FloorUp to 240minutes150 Solid masonry work*, witha density no les than650 ReportsWF Test Report No. 166576 Backing MaterialsPEPolyethylene, with a nominal density of wool, with a nominal density of 100kg/m34.