Transcription of QUICK SCOPE - Mitutoyo
1 Small Tool Instruments and Data Management Test Equipment and Seismometers digital Scale and DRO Systems Coordinate Measuring Machines Sensor Systems Optical Measuring Form Measurement Vision Measuring Systems Small Tool Instruments and Data Management Test Equipment and Seismometers digital Scale and DRO Systems Coordinate Measuring Machines Sensor Systems Optical Measuring Form Measurement Vision Measuring Systems Catalog No. E4142-359 QUICK SCOPEV ision Measuring SystemsNon-contact Vision Measuring Machine Offers High Accuracy, Real Affordability and Powerful Functionality!2 Compatibility between Ease of Operation and Enhanced Image Processing FunctionsIn industry, where the need for high-accuracy non-contact measurement currently increases, high-speed and high-accuracy vision systems are becoming the mainstream in non-contact precision QUICK SCOPE series are vision measuring microscopes that anyone can easily use to perform not only image observation and single part measurement.
2 But also automatic multiple part SCOPE powerfully supports your vision measurement applications in most diverse & Development DivisionSoftwareVision measuring software system QSPAK continues and various applications s o f t w a r e p r o v i d e y o u w i t h multifunctional analysis, high-speed image processing, and ease of software to control QUICK ScopeLinear Scale manufactureIodine absorption stabilized He-Ne laser (633nm, for length standards)TraceabilityMitutoyo offers calibration services of various kinds from a unique domestic company that is home to nationally accredited calibration laboratories in three fields - laser sources for length measurement, end standards, and line standards.
3 Also, as a comprehensive manufacturer of precision instruments, Mitutoyo provides a number of measuring instruments traceable to national standards, such as coordinate measuring machines, optical measuring instruments, and form measuring instruments as well as vision measuring design and manufactureOptical systemThe optical system used in QUICK SCOPE is manufactured based on leading-edge optical technologies Mitutoyo has developed over the is an ideal optical system that provides an even and flare-free image over the entire visual Series LineupQSQS-L/AFBQS-LZBQS-EBThe QUICK SCOPE series can be used for measurement in various industries for such products as molded-plastic parts, machined parts, cutting tools, and electronic measuring software system QSPAK, that combines excellent operability with high functionality.
4 Aids customers in meeting measurement additional use of application software FORMPAK-QV can extend QSPAK capabilities to enable form assessment and partPressed partCutting toolPrinted circuit boardWorkpiece examplesDrive methodFocusOptical systemImage detecting unitCNC all axesAFFixed/zoom lens selectableColor CCD cameraDrive methodFocusOptical systemImage detecting unitXY: ManualZ: CNCAFF ixed-magnification/zoom selectableColor CCD cameraDrive methodFocusOptical systemImage detecting unitManual all axesContrast-level functionZoomCMOS color cameraDrive methodFocusOptical systemImage detecting unitManual all axesContrast-level functionFixed-magnificationCMOS color camera4 Stage variations QUICK release mechanism Applicable models: QS-L/AFB, QS-LZB, QS-EB Illumination functions provide excellent support for measurement and observation Left and right knobs on the Z-axis feed mechanism Applicable models: QS-LZB, QS-EB AF tool Applicable models.
5 QS, QS-L/AFBD rastic Improvement in Working Efficiency Thanks to Functions Focused on OperabilityThe QS series stage lineup offers two sizes with an XY measuring range of 200 200mm and 200 QS-L/AFB, QS-LZB, and QS-EB stage lineup comprises three sizes with an XY measuring range of 200 100mm, 300 170mm and 400 200mm, QUICK release mechanism is installed on the XY stage of those feed can be switched between Coarse and Fine (FREE and LOCK). Since this mechanism puts the stage in a completely free state, it greatly eases moving the stage if it is a long way to the next measuring release knobIn addition to contour and surface illumination, QUICK SCOPE is equipped with a fiber-optic ring light to aid in reproducing color images more illumination enables measurement and observation of images under optimal conditions.
6 * The fiber-optic ring light for the QS-EB is (stage) illuminationSurface (coaxial) illuminationFiber-optic ring illuminationDuring auto-measurement the measurement procedure program executes automatic control over the illumination system , providing compatibility between user-friendliness and high feed knobs are fitted to both sides of the to avoid restricting the choice of focusing outside coarse-feed knob adjusts the Z axis 30mm per revolution and the inside fine-feed knob feeds at per type of dual-concentric coarse- and fine-feed control dramatically improves knobFine-feed knobImage before AFImage after AFThe AF (Auto focus) tool allows focusing without personal error, therefore achieving high-accuracy height Programmable power zoom Applicable models: Zoom lens models of QS and QS-L/AFB, QS-LZB Control box Applicable models: QS, QS-L/AFB, QS-LZB digital zoom function Applicable models: QS-LZB, QS-EBZooming from low to high magnifications can support your task from wide-field observation to high-magnification measurement without changing , the automatic light control function associated with a zooming operation and automatic correction functions, such as for image displacementand pixel calibration, are installed in these , QS-L/AFB: (28X 193X) at 8 steps, 7X zoomQS-LZB.
7 (30X 208X) at 8 steps, 7X zoom* Each numeral in parentheses indicates the image magnification using a 19-inch LCD operations such as illuminating, data entry, zooming, and auto-focusing* can be performed with a single touch of individual buttons conveniently positioned near at CNC QS system allows remote operation with a jog shuttle. The manual QS system can be operated with a single touch of a button in the case of repeated measurement.* Function available only in QS and QS- QSFor QS-L/AFBFor QS-LZBE very click on the menu icon magnifies an image display from normal 1X to 2X and then image can be measured by digital -zooming in every examples in QS-LZB681590018006634657401403160 system diagram Dimensions SpecificationsObjective lenses* (02 AKT199) (02 ALA410)QV-1X (02 ALA400)QV-5X (02 ALA420)Optional accessoriesCalibration chart (with holder)(02 ATN695)QS Compensation chart(with holder)(02 AKW001)Dedicated table(02 ATE760)QSFixed lens systemQS200/QS250 Color CCD cameraZoom lens systemQS200Z/QS250 ZContour IlluminationQS controller (QSC-10)Stop switchSurface (coaxial)
8 IlluminationFiber-optic ring lightIllumination UnitSelectableControl box 2(02 APW610)Joystick box(02 ATD415)Foot Switch (937179T)PC setFrame grabberMotion controllerCPU main unitMouseKeyboard19-inch LCD monitorSoftwareQSPAKS oftware (optional)Color ink-jet printer(02 AUQ174)Monochrome laser printer (02 AUQ174)Printer Optical system magnification ratios available for QS and QS-L/AFBM onitor magnification28X36X47X55X83X111X138X193X 276 XVisual field (mm) lens distance (mm) lens distance (mm)55*The values of monitor magnification indicate those for a 19-inch LCD monitor. Each lens of a fixed lens system is specification Option*1 Concurrent use impossible (switching required)*2 Unavailable in zoom lens systems*1 CNC Vision Measuring SystemQSQS250 ZUnit: mm*1 Company standard (fixed lens system : , zoom lens system : at the time of zooming in) under an installation environment of 20 C and during use of the standard lens*2 Value in the case of selecting the color ink-jet printer (12 AAC761)*Suffix code according to AC line voltage: C for 110V AC, A for 120V AC, D for 120V AC, E for 240V AC, no suffix for 100V ACFixed lens systemModelQS200QS250 Order No.
9 359-506-8*Zoom lens systemModelQS200 ZQS250 ZOrder *359-508-8*Drive methodCNCR ange (X Y Z)mm200 200 100 (8" 8" 4")200 250 100 (8" 10" 4")Resolution/Length m/Linear encoderImage detecting unit1/3" Color CCD cameraMeasuring accuracy*1XY( +6L/1000) mZ(5+6L/1000) mDrive speedMax 80mm/sAcceleration and glass size269 261 (11" 10")269 311 (11" 12")Maximum stage loading10kg (22lbs.)IlluminationContour Illumination: 12V/30W Halogen Reflected Illumination: 12V/50W HalogenFiber-optic ring light: 12V/100W HalogenDimensions (W D H)mm465 815 663 (18" 32" 26")Mass76kg (169lbs.)Power consumption*2970W at max7624 (682)Maximum: 824 (956)Maximum: 755 (937)100 (150)50 (85) 705 (852)100 (124)205 (247)722 (837)945 (987)1462 (1577)7401800900 Maximum: 967 Maximum: 1157867100200757200837740987157724790018 00 Fixed lens systemModelQS-L2010/AFBQS-L3017/AFBQS-L4 020/AFBO rder *359-701*359-702*Zoom lens systemModelQS-L2010Z/AFBQS-L3017Z/AFBQS- L4020Z/AFBO rder *359-704*359-705*Feed mechanismXY-axis: manual / Z-axis.
10 Motor-driven with auto-focusRange (X Y Z)200 100 150mm300 170 150mm400 200 150mmResolution / Length m / Linear encoderImage detecting unit1/3" color CCD cameraMeasuring accuracy*1XY( +20L/1000) mZ(5+6L/1000) mStage glass size (mm)250 150 (10" 6")370 240mm440 240mmMaximum stage loading10kg (22lbs.)20kg (44lbs.)15kg (33lbs.)IlluminationContour Illumination: 12V/30W HalogenReflected Illumination: 12V/50W HalogenFiber-optic ring light: 12V/100W HalogenDimensions*2 (W D H)Main Unit624 705 722mm682 852 837mm757 867 837mmPower Unit186 452 381mmMassMain Unit66kg (147lbs.)134kg (298lbs.)140kg (311lbs.)Power Unit14kg (31lbs.)Power consumption400W at max. Dimensions Specifications system diagramObjective lenses* (02 AKT199) (02 ALA410)QV-1X(02 ALA400)QV-5X(02 ALA420)Common optionsCalibration chart (with holder)(02 ATN695)Correction chart (with holder)(02 AKW001)Dedicated table(02 ATE760)QS-L/AFBF ixed lens systemQS-L2010/AFB QS-L3017/AFB QS-L4020/AFBC olor CCD cameraZoom lens systemQS-L2010Z/AFB QS-L3017Z/AFB QS-L4020Z/AFBC ontour IlluminationPower UnitStop switchSurface illuminationFiber-optic ring lightIllumination unitSelectableFoot switch(937179T)Ruggedized-type foot switch(12 AAJ088)