ROBERTS GORDON NRG Control

ROBERTS GORDON . NRG Control Energy Saving Control for ROBERTS GORDON Infrared and . Warm Air Heating Equipment Installation, Operation and Service Manual Installer WARNING. Please take the time to read and understand Improper installation, adjustment, alteration, service or maintenance can result in death, injury or these instructions prior to any installation. property damage. Read the Installation, Operation Installer must give a copy of this manual to the owner. and Service Manual thoroughly before installing or Owner servicing this equipment. Keep this manual in a safe place in order to provide Installation must be done by an electrician qualified your serviceman with necessary information.

Roberts-Gordon Europe Limited Unit A, Kings Hill Business Park Darlaston Road, Wednesbury West Midlands, WS10 7SH UK Telephone: +44 (0)121 506 7700

Tags:

  Control, Unit, Robert, Gordon, Roberts gordon

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ROBERTS GORDON NRG Control

1 ROBERTS GORDON . NRG Control Energy Saving Control for ROBERTS GORDON Infrared and . Warm Air Heating Equipment Installation, Operation and Service Manual Installer WARNING. Please take the time to read and understand Improper installation, adjustment, alteration, service or maintenance can result in death, injury or these instructions prior to any installation. property damage. Read the Installation, Operation Installer must give a copy of this manual to the owner. and Service Manual thoroughly before installing or Owner servicing this equipment. Keep this manual in a safe place in order to provide Installation must be done by an electrician qualified your serviceman with necessary information.

2 In the installation and service of Control systems for heating equipment. ROBERTS - GORDON Europe Limited unit A, Kings Hill Business Park Darlaston Road, Wednesbury West Midlands, WS10 7SH UK. Telephone: +44 (0)121 506 7700. Fax: +44 (0)121 506 7701. Service Telephone: +44 (0)121 506 7709. Service Fax: +44 (0)121 506 7702. E-mail: E-mail: 2012 ROBERTS - GORDON Europe Limited P/N X235 Rev F 06/12. TABLE OF CONTENTS. SECTION 1: 2. Safety Labels and Their Placement .. 2. What is a ROBERTS GORDON NRG Control ? .. 2. General Requirements .. 2. Control Location .. 2. Network 2. Installation 3. Programming Details .. 3. SECTION 2: Specifications .. 4. Material Specifications.

3 4. Keypad Layout .. 4. SECTION 3: 6. Installing the ROBERTS GORDON NRG Control .. 6. Electrical Installation 7. SECTION 4: 9. Network Wiring .. 9. Low Voltage Wiring .. 10. CTU Wiring .. 11. CTCU 11. Interface Relay Wiring for Multiple Warm Air 12. PGP/POP Range Wiring - 1 Cabinet Heaters .. 12. PGP/POP Range Wiring - 3 Cabinet Heaters .. 13. Cabinet Heater Remote Lockout Reset Wiring .. 13. Unitary Radiant System Wiring .. 14. CORAYVAC and Multiburner Systems Wiring .. 15. SECTION 5: Programming and Operation .. 16. Stand Alone 16. Network unit .. 16. System Language .. 16. Network Open Level User Functions .. 18. Manager 22. Engineer Settings.

4 28. SECTION 6: Standard Screen Messages .. 36. Stand Alone Control Screen Messages .. 36. Network Control Screen Message .. 37. Fault Messages .. 37. 2012 ROBERTS - GORDON Europe Limited All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the written permission of ROBERTS - GORDON Europe Limited. Printed in TABLE OF FIGURES. Figure 1: Keypad Layout .. 4. Figure 2: Remote Sensors .. 5. Figure 3: Cover Detail .. 6. Figure 4: Mounting Hole Layout.

5 6. Figure 5: Cable Entry .. 6. Figure 6: Control Terminals and Relay 7. Figure 7: Ferrite EMC Filter .. 7. Figure 8: Sensor Mounting Plate - Warm Air .. 7. Figure 9: Remote Temperature Sensor - Radiant .. 8. Figure 10: Sports Hall Sensor .. 8. Product Approval ROBERTS GORDON appliances have been tested and CE certified as complying with the essential requirements of the Gas Appliance Directive, the Low Voltage Directive, the Electromagnetic Compatibility Directive and the Machinery Directive for use on natural gas, LPG. and fuel oil when installed, commissioned and maintained in accordance with these instructions. These instructions refer to appliances designed to operate in the European Union.

6 Appliances designed for other countries (non European Union) are available on request. This appliance must be installed in accordance with the local and national codes in force and used only in a sufficiently ventilated space, as specified in these instructions. Before installation, check that the local gas distribution systems, nature of gas and pressure, and adjustment of the appliance are compatible. 1. ROBERTS GORDON NRG Control INSTALLATION, OPERATION AND SERVICE MANUAL. SECTION 1: INTRODUCTION Heaters with two stage High/Low operation Your Safety is Important to Us! Heaters with modulating burners requiring a 0- This symbol is used throughout 10V DC input the manual to notify you of *For safe use of multiburner and CORAYVAC systems with up possible fire, electrical or burn to four zones operating with a single shared fan, the additional use of the ROBERTS GORDON System Control will be hazards.

7 Please pay special required with a ROBERTS GORDON NRG Control installed for attention when reading and fol- each zone. lowing the warnings in these sections. Features of the ROBERTS GORDON NRG. Installation, service and annual inspection of Control . controller must be done by an electrician qualified in Coded access to set up and network functions to the installation and service of Control systems for heating equipment. prevent unauthorised access. Installation, service and annual inspection of heater Built in temperature sensor. must be done by a contractor qualified in the installation and service of gas or oil fired heating Remote temperature sensor option.

8 Equipment. Self learning optimum start. Read this manual carefully before installation, Automatic correction for daylight saving time operation, or service of this equipment. The appliance must be applied and operated under changes. the general concepts of resonable use and installed Burner lockout indication and reset for suitable using best building practices. heater systems. This appliance is not intended for use by persons (including children) with reduced physical, sensory Pre programmed holiday functions. or mental capabilities, or lack of experience and May be connected on a network to give access knowledge, unless they have been given supervision or instruction concerning use of the to all controls from a single point.

9 Appliance by a person responsible for their safety. Programmed in 5 languages as standard. Children should be supervised to ensure that they do not play with the appliance. Data logging of hours run and temperatures. For optimum heater performance and safe heating conditions, inspect and maintain heater(s) before General Requirements every heating season and as necessary. Also, know and maintain heater clearances to combustibles, The ROBERTS GORDON NRG Control is only for see heater Installation, Operation and Service use with ROBERTS GORDON heating products. Manual for further details. If you require additional On site commissioning is required to ensure that the manuals, contact ROBERTS - GORDON at +44 (0)121 506 temperature sensor is calibrated, and that the 7700 or at options available are selected correctly.

10 Before proceeding with installation, it will be necessary to Safety Labels and Their Placement check that the following points have been Product safety signs or labels should be replaced by considered. the product user when they are no longer legible. Please contact ROBERTS - GORDON LLC or your ROB- Control Location ERTS GORDON independent distributor to obtain Each Control is intended to operate a single zone of replacement signs or labels. heating. The built in sensor may be used for temperature Control . In this case, position the Control as in Section through Section What is a ROBERTS GORDON NRG When remote temperature sensors are required, the Control ?