Example: biology

Roots Packaged Blower Units - THEREC KINEMATICS

Roots PackagedBlower UnitsRoots PackagedBlower UnitsSRB Blower Units and SRE exhauster Units Each standard packagedblower or exhauster combines a Roots Blower unit supplying oil-free air with an electricmotor, vee-belt drive, intake filter/silencer, filter restriction indicator, discharge silencer,non return valves and relief valves. The Blower is mounted on a rigid baseplate andcontained within a practical acoustic enclosure, which reduces radiated noise levelsfor noise sensitive SRB range covers pressures from 300 to 1000 mbar ( ) with inletvolumes from 50m3/h to 300m3/h. The SRE range covers 300 mbar to 500 mbar( to ). Pressure relief and non-return valves are supplied loose forinstallation into customer s pipework.

SRB blower units and SRE exhauster units Each standard packaged blower or exhauster combines a Roots blower unit supplying oil-free air with an electric motor, vee-belt drive, intake filter/silencer, filter restriction indicator, discharge silencer,

Tags:

  Unit, Blower, Packaged, Root, Roots blowers, Roots packaged blower units

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Roots Packaged Blower Units - THEREC KINEMATICS

1 Roots PackagedBlower UnitsRoots PackagedBlower UnitsSRB Blower Units and SRE exhauster Units Each standard packagedblower or exhauster combines a Roots Blower unit supplying oil-free air with an electricmotor, vee-belt drive, intake filter/silencer, filter restriction indicator, discharge silencer,non return valves and relief valves. The Blower is mounted on a rigid baseplate andcontained within a practical acoustic enclosure, which reduces radiated noise levelsfor noise sensitive SRB range covers pressures from 300 to 1000 mbar ( ) with inletvolumes from 50m3/h to 300m3/h. The SRE range covers 300 mbar to 500 mbar( to ). Pressure relief and non-return valves are supplied loose forinstallation into customer s pipework.

2 Both packages have hinged access withsecurity Blower unitsThe MRB range of standard package Units offer pressures from300 mbar to 1000 mbar ( to 30kW) and inlet volumes from 400m3/h to 1400m3 MRB package combines a Roots URAI Blower unit supplying oil free air with anelectric motor, vee-belt drive, intake filter/silencer, discharge silencer, filter restrictionindicator, non return valve and pressure relief valve. The Blower is mounted on a rigidbaseplate with fork-lift slots and contained within a fan vented acoustic enclosure,which reduces radiated noise levels for noise sensitive pressure relief valve and non-return valve aresupplied loose for installation into customer spipework.

3 The package has hinged access withsecurity exhauster Units The MRE offersvacuums from 200 mbar to 500 mbar ( to 30kW)with all the features of the packages comply with the EU machinery directive withregard to CE the heart of the SRB/E and MRB/E PackageReliability is at the heart of every package inthe form of the DRESSER Roots UniversalRAI Blower / exhauster. The URAI isdesigned, precision machined and builtusing the latest computer aidedmethods. This ensures close tolerancesbetween the impellers, casing andheadplates to minimise back slippageof air and improve both efficiency andreliability. The DRESSER Roots exclusive Figure of 8 gearbox design improvesoil distribution and lengthens bearing andgear life.

4 Oversize anti-friction bearingssupport the shafts. On the drive end,cylindrical roller bearings carry vee-belt sideloading and extend service for lifting with forklift truckChannels for lifting with forklift truckChannels for lifting with forklift truckLWHHWLHWLLWHC hannels for lifting with forklift truckdimensionsSRB Blower UNITLWH mmmmmmA Pack 800600725B Pack 1100950850 SRE EXHAUSTER UNITLWH mmmmmmA Pack 800600725B Pack 1100950850 MRB Blower UNITLWH mmmmmm130011001100 MRE EXHAUSTER UNITLWH mmmmmm130011001100terPackagesOther models available on requestAir volumes atBlowerOperating1013 mbar aMotorUnitspressureand 20 CsizeWeightPackmbarm3/hrcfmkWKgsizeSRB are 4% based on

5 Inlet air at temperature of 20 deg C, inletpressure of 1013 mbarA and RH of 0%.Air volumes atBlowerOperating1013 mbar aMotorUnitspressureand 20 CsizeWeightPackmbarm3/hrcfmkWKgsizeMRB 5100500100058922700 MRB 5105500105061830790 MRB 5120500120070630790 MRB 5130500130076530790 MRB 604060040023511570 MRB 604560045026515570 MRB 605060050029415570 MRB 605560055032415570 MRB 606060060035315620 MRB 607560075044122620 MRB 608060080047122620 MRB 608560085050022620 MRB 609060090053022620 MRB 704570045026515570 MRB 707070070041222690 MRB 708570085050030770 MRB 804080040023515580 MRB 905090050029422650 MRB 10045100045026422650 MRB 10050100050029422650 Ratings based on inlet air at temperature of 20 deg C, inlet pressure of1013 mbarA and RH of 0%.

6 Air volumes atExhauster Vacuum1013 mbar aMotorUnitsand 20 CsizeWeightPackmbarm3/hrcfmkWKgsizeSRE are 4% based on inlet air at temperature of 20 deg C, inletpressure of 1013 mbarA and RH of 0%.MRB 306530065038311570 MRB 307030070041211570 MRB 308030080047111570 MRB 309030090053011620 MRB 3100300100058915620 MRB 404040040023511425 MRB 404540045026511425 MRB 405040050029411425 MRB 405540055032411448 MRB 406040060035311570 MRB 406540065038315570 MRB 407540075044115570 MRB 408540085050015620 MRB 4125400125073622700 MRB 4130400130076522700 MRB 4135400135079322700 MRB 4140400140082330785 MRB 504050040023511570 MRB 504550045026511570 MRB 505050050029411570 MRB 505550055032415570 MRB 506050060035315570 MRB 506550065038315570 MRB 507050070041215570 MRB 2100200100058911640 MRE 2120200120070615640 MRE 2140200140082415640 MRE 36030060035311570 MRE 38030080047111570 MRE 3100300100058915640

7 MRE 45540055032411570 MRE 47040070041215570 MRE 4120400120070622700 MRE 4130400130076522700 MRE 55050050029415570 MRE 58550085050022700 MRE 5100500100058930780 MRE 5115500115067730780 MRE 5130500130076530780 Ratings based on inlet air at temperature of 20 deg C, inlet pressure of1013 mbarA and RH of 0%.performance dataExtra Low Pulse Units The PRIME package unit rangefeatures fivedifferent standard designs. All PIME packages can besupplied with easy access enclosures for noise sensitive a guide, individual package noise levels are between 70 and 85dBA at 1 metre from the package perimeter in free-field conditions,depending on site contact our sales department for noise levels at specificoperating conditions or to discuss noise packages comply with EU machinery directive with regard to CE PRIME Units are supported by a full manufacturer s warranty and sales and service support is available from the DRESSERR oots Huddersfield facility in the UK and from our worldwide after-market support PRIME Units are designed to be user friendly and to demonstrate the following key features.

8 Extremely compact design Low installation cost Short installation cycle time Low operation costs Easy maintenance accessDue to the increased use of common components and astandardised design concept, the PRIME range of packageunits are available on short lead Roots XLP AdvantageThe XLP Whispair Blower isdesigned to reduce noise and powerloss by utilising an exclusive wrap-around plenum and proprietary double*jet Whispair feature to control pressureequalisation and increase proven design concepts of the 3lobe impeller profile together with thedouble jet Whispair feature, combineto produce such low pulsation levelsthat inlet and discharge silencers areno longer required to control in-pipenoise and pulsation.

9 This in turn allowsfor an extremely compact and costcompetitive package unit design.* XLP N08 and N10 have a single jet PACKSD imensions (mm)LW1W2H1H2 ZMRN13001100110011001100 Lift off lid N18001400170019001750800*A21001500194020 001780950*B260017002200270024501200*C300 014002500290026501350*DRefer to factory Removable Panels* 2 doors each sideEnclosureSizeterPackagesMODELXLP 110 XLP 108 SPEED1650 2000 2500 3000 3500 4200 1650 2000 2500 3000 3500 4200 Vol (m3/hr)845 1071 1394 1717 2040 2492 1127 1429 1860 2290 2721 3324300 t (c)313030293031313029293031mbarMotor (kw) (m3/hr)811 1037 1360 1683 2005 2457 1082 1383 1814 2245 2676 3279400 t (c)424139393940424139393940mbarMotor (kw) (m3/hr)

10 781 1007 1330 1653 1975 2427 1042 1343 1774 2205 2636 3239500 t (c)555250494949555250494949mbarMotor (kw) (m3/hr)754980 1303 1625 1948 2400 1006 1307 1738 2169 2599 3202600 t (c)686461595959686461595959mbarMotor (kw)223037455555303745557575 Vol (m3/hr)729955 1278 1600 1923 2375 972 1274 1705 2135 2566 3169700 t (c)827672706969827672706968mbarMotor (kw)223037455575374555757590 Vol (m3/hr)706932 1254 1577 1900 2352 941 1243 1674 2104 2535 3138800 t (c)968983817978968983807978mbarMotor (kw)3037455575753745557575110 Vol (m3/hr)684910 1233 1555 1878 2330900 t (c)11210295928988mbarMotor (kw)304545557575 Vol (m3/hr)889 1212 1535 1858 23101000 t (c)11610710310098mbarMotor (kw)