Rosemount 333 HART Tri-Loop - Emerson

Product Data Sheet September 2015. 00813-0100-4754, Rev GB. Rosemount 333 hart Tri-Loop . hart -to-Analog Signal Converter Convert a digital hart signal into three additional analog signals Easy to configure and install Accessory product for multivariable instruments Available as either high-alarm or low-alarm device Rosemount 333 September 2015. hart Tri-Loop hart -to-Analog Signal Converter Convert a digital hart signal into three analog signals Easy to configure and install Convert a multivariable digital hart signal into independent The 333 hart Tri-Loop is easy to configure and maintain 4-20 mA analog process variables using the Rosemount 333 using the 475 Field Communicator.

2 Rosemount 333 September 2015 www.rosemount.com HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three analog signals Convert a multivariable digital HART signal into independent

Tags:

  Loops, Rosemount, Hart, Rosemount 333 hart tri loop

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Rosemount 333 HART Tri-Loop - Emerson

1 Product Data Sheet September 2015. 00813-0100-4754, Rev GB. Rosemount 333 hart Tri-Loop . hart -to-Analog Signal Converter Convert a digital hart signal into three additional analog signals Easy to configure and install Accessory product for multivariable instruments Available as either high-alarm or low-alarm device Rosemount 333 September 2015. hart Tri-Loop hart -to-Analog Signal Converter Convert a digital hart signal into three analog signals Easy to configure and install Convert a multivariable digital hart signal into independent The 333 hart Tri-Loop is easy to configure and maintain 4-20 mA analog process variables using the Rosemount 333 using the 475 Field Communicator.

2 AMS Device Manager hart Tri-Loop . Apply in control or monitoring applications to provides easy PC-based user configuration. Installation is obtain up to three additional analog outputs without quick and easy with three DIN rail mount options and additional process penetrations. electrically isolated analog output channels for flexible grounding. Accessory product for multivariable instruments Available as either high-alarm or low-alarm device For use with the Rosemount 3051S MultiVariable , 3051S. Advanced hart Diagnostics, and 3144P products. When Tri-Loop alarm channels are factory configured.

3 All channels used with the 3051S MultiVariable Transmitter, the 333 hart alarm if the attached device indicates a sensor failure or Tri-Loop allows possible outputs of Differential, Absolute or transmitter malfunction. Gage pressure, Process Temperature, Mass or Volumetric Flow, Energy Flow, Totalized Flow, and Sensor Module Temperature. When used with the 3051S Advanced hart . Diagnostics, possible outputs include Pressure, Sensor Module Temperature, Scaled Variable, Standard Deviation, and Mean. When used with the Rosemount 3144P, possible outputs include Sensor 1, Sensor 2, Differential and Transmitter Terminal Temperature.

4 Figure 1. Example Tri-Loop Installation with Rosemount 3051S MultiVariable Transmitter HAZARDOUS AREA DIN. Rail Mounted hart Tri-Loop Each Tri-Loop Channel receives Ch. 3 power from Control Room Ch. 2. Ch. 1 Channel 1 must be powered for the Burst Input Tri-Loop to operate to Tri-Loop Rosemount 3051S. MultiVariable Transmitter RL 250 . Device receives power from Control Room hart Burst Command 3/ for Primary Variable Analog Output Loop Intrinsically Safe Barrier Control Room NON HAZARDOUS AREA. Contents Ordering Information .. 3 Dimensional Drawings ..5.

5 Specifications ..3. 2 September 2015 Rosemount 333. Ordering Information Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 4 for more information on Material Selection. Table 1. Rosemount 333 hart Tri-Loop H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Model Product description 333 hart Tri-Loop Alarm option U High alarm H. D Low alarm H.

6 Configuration option C2 Custom configuration (Configuration Data Sheet must be completed) H. Typical model number: 333 U. Specifications Functional specifications Load limitations Loop resistance is determined by the voltage level of the Service external power supply, as described below: Accessory product for use with the 3051S MultiVariable Max. Loop Resistance = Power Supply Transmitter, 3051S Advanced hart Diagnostics Transmitter, 3144P Temperature Transmitter, or any other hart device with a burst mode output. 1400. Output 1200. Load (Ohms). 1000. One, two, or three 4 20 mA user-selectable output signals.

7 800. Device Output options 600. 400 Operating DP, AP, GP, PT, Mass or Volumetric, 200 Region 3051S. Energy Flow, Totalized Flow, and Sensor 0. MultiVariable 10 20 30 40 Module Temperature Power Supply Voltage, Vdc Pressure, Sensor Module Temperature, 3051S Scaled Variable, Standard Deviation, and Mean Turn-on time Analog signals will be within specifications five seconds after Sensor 1, Sensor 2, Differential power is applied to Tri-Loop . 3144P Temperature, or Transmitter Terminal Temperature Installation locations Approved for FM ordinary locations, approved for CSA ordinary Power supply locations.

8 External power supply required for each channel. Each channel operates on terminal voltage of 11 Vdc. Temperature limits Ambient Note 50 to 104 F (10 to 40 C). Channel 1 must be powered for Tri-Loop operation. Storage 40 to 158 F ( 40 to 70 C). Humidity limits 0 95% non-condensing relative humidity 3. Rosemount 333 September 2015. Failure mode alarm Physical specifications If Tri-Loop diagnostics detect a Tri-Loop failure or the transmitter indicates a transmitter malfunction, the analog signal for all Material selection channels will be driven either below mA or above mA Emerson provides a variety of Rosemount products with various to alert the user.

9 The high or low alarm signal is determined by product options and configurations including materials of the Tri-Loop Model Number, see construction that can be expected to perform well in a wide Alarm configuration on page 4. range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser's Performance specifications sole responsibility to make a careful analysis of all process (Performance specifications are for the hart Tri-Loop only.) parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.)

10 , when Reference accuracy specifying product materials, options, and components for the of span particular application. Emerson Process Management is not in a Ambient temperature effect per 50 F (28 C) position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product of span options, configuration, or materials of construction selected. Stability Electrical connections of span for 12 months Screw clamps accepts 24 12 AWG solid or stranded wire. Analog output update Dimensions Tri-Loop responds to every hart burst update (typical x 3 in.)