Example: barber

Rui Barbosa, 1020 - P.O. BOX 91 Phone: +55 47 3441-2121 ...

H E R M E T I C C O M P R E S S O R S. Rui Barbosa, 1020 - BOX 91. 89219-901 - Joinville - SC - Brazil Phone: +55 47 3441-2121 . Fax: +55 47 3441-2780. Brazil Via Buttigliera 6. 10020 - Riva Presso Chieri (Torino) - Italy BOX 151 - 10023 Chieri (TO). Phone: +39 011 943-7111. Fax: +39 011 946-8377. +39 011 946-9950. Italy R-290. Subject to alteration without previous notice. - Code 08004 - Date January 2010 - Version 01. Europe - Sales Office Zona Industriale D1 - Via Fratelli Gambino, 7. 10023 - Chieri (Torino) - Italy Phone: +39 011 940-5611. Fax: +39 011 940-5656. Odorinska Cesta, 2 - 052-01. Spissk Nov Ves - Slovakia Phone: +42 153 417-2291. +42 153 417-2293. Fax: +42 153 417-2299. Slovakia Mexico - Sales Office Av. Lazaro Cardenas 2321 - Piso 3.

Propane Product Line EM F NE NT R-290 HERMETIC COMPRESSORS a wit previou otice.-0800 a 2010-V ers 01. www.embraco.com Rui Barbosa, 1020 - P.O. BOX 91 89219-901 - Joinville - SC - Brazil

Tags:

  Propane, R 290

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Rui Barbosa, 1020 - P.O. BOX 91 Phone: +55 47 3441-2121 ...

1 H E R M E T I C C O M P R E S S O R S. Rui Barbosa, 1020 - BOX 91. 89219-901 - Joinville - SC - Brazil Phone: +55 47 3441-2121 . Fax: +55 47 3441-2780. Brazil Via Buttigliera 6. 10020 - Riva Presso Chieri (Torino) - Italy BOX 151 - 10023 Chieri (TO). Phone: +39 011 943-7111. Fax: +39 011 946-8377. +39 011 946-9950. Italy R-290. Subject to alteration without previous notice. - Code 08004 - Date January 2010 - Version 01. Europe - Sales Office Zona Industriale D1 - Via Fratelli Gambino, 7. 10023 - Chieri (Torino) - Italy Phone: +39 011 940-5611. Fax: +39 011 940-5656. Odorinska Cesta, 2 - 052-01. Spissk Nov Ves - Slovakia Phone: +42 153 417-2291. +42 153 417-2293. Fax: +42 153 417-2299. Slovakia Mexico - Sales Office Av. Lazaro Cardenas 2321 - Piso 3.

2 propane Product Line EM. 2800 Vista Ridge Drive NE. Suwanee, GA 30024-3510. Residencial San Agustin BOX 66260 - San Pedro Garza Garcia Nuevo Leon - Mexico F. Phone: +1 678 804-1337. Fax: +1 678 804-1338. Phone: +52 81 1001-7102. Fax: +52 81 1001-7142 NE. NT. 29 Yuhua Road Area B of Beijing Tianzhu Airport Industrial Zone 101312 - Beijing - China Phone: +86 10 8048-2255. Fax: +86 10 6725-6825. China Embraco is participating in the United Nations Global Compact. propane Product Line propane (R-290) Compressor Line propane (R-290) Product Line Benefits Embraco is a Global Market and Technological Leader in Higher efficiency and capacity Hermetic Compressors for Refrigeration. Lower noise As one of the pioneers in the development Lower refrigerant cost of environmentally friendly products, Embraco reinforces its Lower discharge temperature commitment to global sustainability Great ecological appeal by offering a full range of high efficiency compressors for light commercial applications utilizing propane (R-290) as a refrigerant.

3 This natural refrigerant does not contribute to ozone layer External Views depletion or to the greenhouse effect. 203 mm - . propane brings lower noise levels. It also provides significant 229 mm - . 16 mm - (x6). gains in refrigeration capacity and efficiency, using the same 100 mm - . 70 mm - . refrigerant mass when compared to the current HFC refrigerants. 150 mm - . EMI. EMI. 155 mm - . Embraco as a Global supplier produces propane (R-290) compressors in South America, Europe and Asia assuring high service levels 170 mm - . 7 mm - (x2). 178 mm - . to all our customers around the world. Product Data - propane (R-290) Refrigerant 228 mm - mm - . Performance C + C (*). Voltage / Frequency Test Frequency Displacement 16 mm - (x6). Series Model Motor Type Application (HP) Capacity EER.

4 (V/Hz) (Hz) (cm3). mm - . 70 mm - . 100 mm - . W kcal/h W/W Kcal/Wh EMT. EMT. 158 mm - . EMI50 UER 115-127 V 60 Hz 1 ~ RSIR-CSIR LBP 60 1/10 153 132 EMI50 UER 220-240 V 50-60 Hz 1 ~ RSIR-CSIR LBP 60 1/10 153 132 EMI70 UER 115-127 V 60 Hz 1 ~ RSIR-CSIR LBP 60 1/8 205 176 170 mm - . EMI70 UER 220-240 V 50-60 Hz 1 ~ RSIR-CSIR LBP 60 1/8 210 181 178 mm - . EMI90 UEX 115-127 V 60 Hz 1 ~ CSIR L/MBP 60 1/4+ 277 239 EMI90 UEX 220 V 60 Hz 1 ~ CSIR L/MBP 60 1/4+ 277 239 EMI90 UEX 220-240 V 50 Hz 1 ~ CSIR L/MBP 50 1/4+ 229 197 203 mm - 16 mm EM EMT1121U 220-240 V 50Hz 1~ RSCR LBP 50 1/3- 270 231 251 mm - (x6). EMT1125U 220-240 V 50Hz 1~ RSCR LBP 50 1/3+ 301 259 EMT2117U 220-240 V 50 Hz 1 ~ CSIR LBP 50 1/5 184 158 100 mm - . 70 mm - . 173 mm - . EMT2121U 220-240 V 50 Hz 1 ~ CSIR LBP 50 1/4 265 228 207 mm.

5 F. F. EMT2125U 220-240 V 50 Hz 1 ~ CSIR LBP 50 1/3 301 259 P S. EMT6144U 220-240 V 50Hz 1~ CSIR M/HBP 50 1/4- 616 530 D. S. EMT6152U 220-240 V 50 Hz 1 ~ CSIR M/HBP 50 1/4 742 638 P. D. 170 mm - . EMT6165U 220-240 V 50 Hz 1 ~ CSIR M/HBP 50 1/3 840 722 178 mm - . FFU130 UAX 115-127 V 60 Hz 1 ~ CSIR L/MBP 60 1/3+ 399 343 FFU130 UAX 220-240 V 50-60 Hz 1 ~ CSIR L/MBP 50 1/3+ 319 275 FFU130 UAX 220-240 V 50-60 Hz 1 ~ CSIR L/MBP 60 1/3+ 399 343 F 242 mm - . mm - . FFU160 UAX 115-127 V 60 Hz 1 ~ CSIR L/MBP 60 1/2 489 421 19 mm - (x4). 165 mm - . FFU160 UAX 220 V 60 Hz 1 ~ CSIR L/MBP 60 1/2 489 421 16 mm - (x6). FFU160 UAX 220-240 V 50 Hz 1 ~ CSIR L/MBP 50 1/2 399 343 mm - . 162 mm - . 102 mm - . 70 mm - . NEK2117U 220-240 V 50 Hz 1 ~ CSIR LBP 50 1/5 188 162 NE.

6 NE. 200 mm - . NEK1121U 220-240 V 50 Hz 1 ~ RSIR LBP 50 1/4 276 237 NEK2121U 220-240 V 50 Hz 1 ~ CSIR LBP 50 1/4 247 212 P S D D. NEK2125U 220-240 V 50 Hz 1 ~ CSIR LBP 50 1/3 316 272 NEK2134U 220-240 V 50 Hz 1 ~ CSIR LBP 50 1/2 449 386 P S. 170 mm - . NEK1150U 220-240 V 50 Hz 1 ~ RSIR LBP 50 1/2+ 601 517 NE. NEK2150U 220-240 V 50 Hz 1 ~ CSIR LBP 50 1/2+ 581 500 NEK6152U 220-240 V 50 Hz 1 ~ CSIR M/HBP 50 1/4 720(*) 620 273 mm - . NEK6165U 220-240 V 50 Hz 1 ~ CSIR M/HBP 50 1/3- 839 721 NEK6181U 220-240 V 50 Hz 1 ~ CSIR M/HBP 50 1/3 949 816 19 mm - (x8) 235 mm - . NEK6210U 220-240 V 50 Hz 1 ~ CSIR M/HBP 50 1/2- 1168(*) 1005 203 mm - 8 . NEK6213U 220-240 V 50 Hz 1 ~ CSIR M/HBP 50 1/2+ 1586 1364 234 mm - . NT. NT. 185 mm - . 114 mm - . 122 mm.

7 154 mm - 6 . NT2160U 220-240V 50Hz 1~ CSIR LBP 50 3/4 703 604 NT2170U 220-240V 50Hz 1~ CSIR LBP 50 1- 816 702 NT NT2180U 220-240V 50Hz 1~ CSIR LBP 50 1 932 800 NT6217U 220-240V 50Hz 1~ CSIR HBP 50 1/2+ 1786 1536 178 mm - 7 . NT6224U 220-240V 50Hz 1~ CSR HBP 50 1 2843 2445 Test Conditions LBP and L/MBP: Evaporating: C (-10 F) | Condensing: C (130 F) | Gas and Ambient: C (90 F) | Liquid: C (90 F) Note: After replacement, the compressor and its accessories must have proper processing, and the components must be recycled according to the material group Test Conditions M/HBP: Evaporating: C (45 F) | Condensing: C (130 F) | Gas and Ambient: 35 C (95 F) | Liquid Subcooling: C (15 F) (ferrous, non-ferrous, polymers, oils, ..) directives. These recommendations are intended to minimize the adverse impacts that may be caused to the environment.


Related search queries