Operating Instructions Sartorius Extend SeriesSartorius Gem and Gold ExtendElectronic Analytical and Precision Balances and Precious Metal Scales98648-013-98 Fran ais: page xxEspa ol: page xxItaliano: page xx2 Contents4 Warnings and Safety Precautions5 Getting Started6 Installation10 Leveling the Balance/Scale11 Below-Balance/Scale Weighing12 Operation12 Display and Operating Elements13 Basic Weighing Function14 Calibration/Adjustment17 Configuration (Operating Menu)17 Functions of the Keys during Configuration18 Menu Navigation; Example: Setting the Language 19 Parameter Settings: Menu20 Parameter Settings: Overview26 Application Programs26 Counting28 Weighing in Percent30 Calculation32 Animal Weighing/Averaging34 Net-total Formulation36 Totalizing38 Mass Unit Conversion40 Density Determination41 ISO/GLP-compliant Printout/Record43 Interface Port49 Pin Assignment Chart 50 Cabling Diagram51 Troubleshooting Guide52 Care and Maintenance53 Recycling54 Overview54 Specifications57 Accessories59 Declaration of Conformity3 Warnings and Safety PrecautionsSafety To prevent damage to the equipment,plea

Operating Instructions Sartorius Extend Series Sartorius Gem and Gold Extend Electronic Analytical and Precision Balances and Precious Metal Scales

Tags:

  Series, Extend, Sartorius extend series, Sartorius, Sartorius extend series sartorius

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Sartorius Extend Series - Windmill Software

1 Operating Instructions Sartorius Extend SeriesSartorius Gem and Gold ExtendElectronic Analytical and Precision Balances and Precious Metal Scales98648-013-98 Fran ais: page xxEspa ol: page xxItaliano: page xx2 Contents4 Warnings and Safety Precautions5 Getting Started6 Installation10 Leveling the Balance/Scale11 Below-Balance/Scale Weighing12 Operation12 Display and Operating Elements13 Basic Weighing Function14 Calibration/Adjustment17 Configuration (Operating Menu)17 Functions of the Keys during Configuration18 Menu Navigation; Example: Setting the Language 19 Parameter Settings: Menu20 Parameter Settings: Overview26 Application Programs26 Counting28 Weighing in Percent30 Calculation32 Animal Weighing/Averaging34 Net-total Formulation36 Totalizing38 Mass Unit Conversion40 Density Determination41 ISO/GLP-compliant Printout/Record43 Interface Port49 Pin Assignment Chart 50 Cabling Diagram51 Troubleshooting Guide52 Care and Maintenance53 Recycling54 Overview54 Specifications57 Accessories59 Declaration of Conformity3 Warnings and Safety PrecautionsSafety To prevent damage to the equipment,please read these operating instructionscarefully before using the balance/scale.

2 !Do not use this equipment in hazardous areas.!The balance/scale may be opened onlyby trained service technicians.!Disconnect the balance/scale frompower before connecting or discon-necting peripheral devices.!If you operate the balance/scale underambient conditions subject to highersafety standards, you must complywith the applicable installation regula-tions.!Exposure to excessive electromagneticinterference can cause the readoutvalue to change. Once the disturbancehas ceased, the instrument can be usedagain in accordance with its sure that no liquid enters theequipment housing; use only a slightlymoistened cloth to clean !Make sure the voltage rating printedon the power supply is identical to yourlocal line voltage. Proceed with extreme caution whenusing pre-wired RS-232 connectingcables, as the pin assignments may notbe compatible with Sartorius equipment.

3 Before connecting the cable, check allpin assignments against the cablingdiagrams and disconnect any lines thatare assigned differently.!If there is visible damage to the equip-ment or power cord, disconnect theequipment from power and lock it in a secure place to ensure that it cannotbe used for the time being. Connect only Sartorius accessories andoptions, as these are optimally designedfor use with your Extend operator shall be solely responsiblefor installation and testing of anymodifications to Sartorius equipment,including connection of cables orequipment not supplied by request, Sartorius will be happy to provide information on operatingspecifications (in accordance with theStandards for defined immunity tointerference).$Do not open the balance/scale the seal is broken, this will result in forfeiture of all claims under themanufacturer s warranty.

4 $If you have any problems with yourbalance/scale, contact your local Sartorius customer service following symbols are used inthese instructions: indicates required steps$indicates steps required only under certain conditions> describes what happens after you haveperformed a particular step indicates an item in a list!indicates a hazard4 Getting StartedStorage and Shipping Conditions Do not expose the balance/scale toextreme temperatures, moisture, shocks,blows or the Equipment After unpacking the equipment, pleasecheck it immediately for any externaldamage.$If you detect any damage, proceed asdirected in the chapter entitled Careand Maintenance, under SafetyInspection. $Save the box and all parts of the packaging for any future transport.

5 Disconnect all cables before packing the balance/scale for Supplied Balance/scale Weighing pan Pan support (only for models with a round weighing pan) Gem tray (GK and GW models only) AC adapterAdditional equipment supplied withmodels ED224S, ED124S, GK1203,GK703, GK303: Sliding-door draft shield Shield ring Shield plate Dust coverAdditional equipment supplied withmodels ED423S-DS, ED323S-DS,ED153-DS, GK2202: Sliding-door draft shieldAdditional equipment supplied withmodels ED623S(-CW), ED523S-P0CE,ED423S(-CW), ED323S(-CW), ED153(-CW): Round glass draft shield with coverInstallationChoose a location that is not subject to the following negative influences: Heat (heater or direct sunlight) Drafts from open windows and doors Excessive vibration during weighing Excessive moistureConditioning the Balance/ScaleMoisture in the air can condense oncold surfaces whenever the equipmentis moved to a substantially warmerplace.

6 To avoid the effects of condensa-tion, condition the weighing instrumentfor 2 hours at room temperature, leaving it unplugged from AC on Balances/Scales Verified forUse in Legal Metrology in the EU*:EU legislation requires that a controlseal be affixed to verified balances/scalesof accuracy class K. The control sealconsists of a sticker with the Sartorius logo. If the seal is broken, the verifica-tion becomes null and void and the balance/scale must be re-verified.* Including the Signatories of the Agree-ment on the European Economic Area5 InstallationSetting Up the Balance/ScaleInstruments with sliding-door draft shield: Place components inside the chamber in the follow-ing order: Shield plate Shield ring (not on models ED423S-DS, ED323S-DS,ED153-DS, GK2202) Pan support Weighing pan Gem tray (GK models only)Instruments with a round glass draft shield: Position the components listed below in the ordergiven.

7 Place the lower lid on the balance/scale with theraised edge facing upwards and turn it until it isfirmly in position Pan support Weighing pan Glass draft shield Gem tray (GK models only) Place the upper lid on the draft shield with theraised edge facing downwardsInstruments with a round weighing pan Position the components listed below in the ordergiven: Pan support Weighing pan Weighing bowl (GW models only)Instruments with a rectangular weighing pan: Place the weighing pan on the balance/scale Weighing bowl (GW models only)6 Connecting the Balance/Scale to AC Power/Safety PrecautionsUse only genuine Sartorius AC adapters. For usewithin Europe: part no. 6971948 Connect the angle plug to the balance/scale Connect the AC adapter to the wall outlet (mains)AC Adapter with Country-specific Power CordSome models come with separate country-specificpower cords for the AC adapter.

8 In Europe, use onlygenuine Sartorius AC adapter part no. 6971982. Connect the angle plug to the balance/scale Select the power cord for your area and connect itto the AC adapter Plug the power cord into the wall outlet (mains)The ground terminal is connected to thebalance/scale housing, which can be additionallygrounded for the required voltage, if necessary. If you need to set the voltage, use one of the following genuine Sartorius adapters: TNG8 adapter, part no. 6971951 (universal)or TNG8 adapter, part no. 6971952 (for the UK) Move the switch to set the voltage to 230 V or 115 V 7 NOTE: This equipment has been testedand found to comply with the limitspursuant to part 15 of FCC limits are designed to providereasonable protection against harmfulinterference.

9 This equipment generates,uses and can radiate radio frequencyenergy and, if not installed and used inaccordance with these instructions, may cause harmful interference to radiocommunications. For information on the specific limitsand class of this equipment, please referto the Declaration of on the particular class, you are either required or requested tocorrect the you have a Class A digital device, you need to comply with the FCC statement as follows: Operation of thisequipment in a residential area is likelyto cause harmful interference in whichcase the user will be required to correctthe interference at his own expense. If you have a Class B digital device,please read and follow the FCC information given below: However, there is no guarantee thatinterference will not occur in a particu-lar installation.

10 If this equipment doescause harmful interference to radio ortelevision reception, which can bedetermined by turning the equipmentoff and on, the user is encouraged totry to correct the interference by one ormore of the following measures: Reorient or relocate the receiving antenna. Increase the separation between theequipment and receiver. Connect the equipment into an outleton a circuit different from that to whichthe receiver is connected. Consult the dealer or an experiencedradio/TV technician for help. Before you operate this equipment,check which FCC class (Class A or ClassB) it has according to the Declaration ofConformity included. Be sure to observethe information of this Declaration8 Connecting Electronic Peripheral Devices Make sure to unplug the balance/scale from ACpower before you connect or disconnect a peripheraldevice (printer or computer) to or from the TimeTo ensure accurate results, the balance/scale mustwarm up for 30 minutes before operation.