Example: stock market

SCHLUTER ALL-SET

INNOVATIVE SOLUTIONS FOR CERAMIC AND STONE TILEMODIFIED THIN-SET MORTAR SCHLUTER ALL-SET SCHLUTER ALL-SET Ceramic and stone tiles are durable, easy to maintain, and hygienic, representing the ideal surface coverings. However, the performance of any surface covering depends on the installation method and materials used. SCHLUTER -Systems offers a variety of systems for tile installation, including uncoupling and waterproofing membranes, shower systems, and building panels. SCHLUTER setting materials are specifically formulated for use with these systems to help ensure successful tile installations in a wide range of applications. Application and FunctionSchluter ALL-SET is a specialized, modified thin-set mortar for use as a bond coat within tile assemblies that is optimized for use with SCHLUTER membranes and boards.

available in both grey and white. Material Properties and Areas of Application Schluter ALL-SET® is a mixture of cement, sand, polymer and additives that sets and gains strength through cement hydration and polymer film formation when mixed with water. It is engineered for use with Schluter membranes and boards, including tile installation.

Tags:

  White, Cement

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SCHLUTER ALL-SET

1 INNOVATIVE SOLUTIONS FOR CERAMIC AND STONE TILEMODIFIED THIN-SET MORTAR SCHLUTER ALL-SET SCHLUTER ALL-SET Ceramic and stone tiles are durable, easy to maintain, and hygienic, representing the ideal surface coverings. However, the performance of any surface covering depends on the installation method and materials used. SCHLUTER -Systems offers a variety of systems for tile installation, including uncoupling and waterproofing membranes, shower systems, and building panels. SCHLUTER setting materials are specifically formulated for use with these systems to help ensure successful tile installations in a wide range of applications. Application and FunctionSchluter ALL-SET is a specialized, modified thin-set mortar for use as a bond coat within tile assemblies that is optimized for use with SCHLUTER membranes and boards.

2 SCHLUTER ALL-SET is smooth and creamy, as well as easy to handle and spread. It is sag-resistant and ideal for setting tile on both horizontal and vertical surfaces. SCHLUTER ALL-SET is suitable for use with ceramic, porcelain, and stone tile, including large and heavy tile, in conjunction with SCHLUTER -Systems uncoupling and waterproofing membranes ( , DITRA, DITRA-HEAT, KERDI, etc.), the SCHLUTER -Shower System, and KERDI-BOARD. SCHLUTER ALL-SET can be used in both interior and exterior systems and is available in both grey and Properties and Areas of ApplicationSchluter ALL-SET is a mixture of cement , sand, polymer and additives that sets and gains strength through cement hydration and polymer film formation when mixed with water.

3 It is engineered for use with SCHLUTER membranes and boards, including tile installation. SCHLUTER ALL-SET is formulated to set and gain strength in a timeframe that fits typical installation practice even when sandwiched between impervious substrates and porcelain tile. SCHLUTER ALL-SET is available in grey and white . Use the white version for applications where the color of the mortar affects the aesthetics of the installation ( , light colored or translucent stone tile, light colored grout). SCHLUTER ALL-SET meets or exceeds the American National Standard Specifications for Modified Dry-Set cement Mortar, ANSI , the American National Standard Specifications for Improved Modified Dry-Set cement Mortar, ANSI , and the American National Standard Specifications for Exterior Glue Plywood Latex-Portland cement Mortar, ALL-SET was evaluated according to the "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, version " for California Specification 01350 and found to comply with the VOC requirements.

4 California Specification 01350 is referenced by various green building standards and rating ALL-SETS chluter SET SCHLUTER ALL-SET SCHLUTER FAST-SET DITRA over:Plywood/OSBX Concrete Gypsum Vinyl flooringXX KERDI over:Gypsum board cement backerboard Fiber- cement board Portland cement mortar KERDI -SHOWER prefabricated substrates TILE over DITRA & KERDI productsCeramic Porcelain Natural stone ( , granite, marble, etc.) 2 Suitable UsesFor SCHLUTER -Systems applications, refer to the SCHLUTER -DITRA, SCHLUTER -DITRA-HEAT, and SCHLUTER -Shower System Installation Handbooks. For other applications, refer to the TCNA Handbook for Ceramic, Glass, and Stone Tile Installation and TTMAC Specification Guide 09 30 00 Tile installation recommended for moisture sensitive stone ( , green marble), resin-backed tile, or glass tileSchluter ALL-SET PropertiesPropertyDuration/ConditionsANS I RequirementANSI RequirementResultsGlazed Wall TileShear Bond Strength7 days>300 psi ( MPa)>450 psi ( MPa)>450 psi ( MPa)7 day water immersion>200 psi ( MPa)>250 psi ( MPa)>250 psi ( MPa)28 day heat agingN/A>450 psi ( MPa)>450 psi ( MPa)Porcelain Mosaic Tile Shear Bond Strength1 day>75 psi ( MPa)>100 psi ( MPa)>100 psi ( MPa)7 days>200 psi ( MPa)>300 psi ( MPa)>300 psi ( MPa)7 day water immersion>150 psi ( MPa)>200 psi ( MPa)

5 >200 psi ( MPa)28 days>200 psi ( MPa)>400 psi ( MPa)>400 psi ( MPa)28 days w/freeze-thaw cycling>175 psi ( MPa)>250 psi ( MPa)>250 psi ( MPa)28 day heat aging>400 psi ( MPa)>400 psi ( MPa)>400 psi ( MPa)12 weeks>200 psi ( MPa)N/A>200 psi ( MPa)Quarry Tile Shear Bond Strength28 days>150 psi ( MPa)>150 psi ( MPa)>150 psi ( MPa)28 days w/freeze-thaw cycling>100 psi ( MPa)>100 psi ( MPa)>100 psi ( MPa)Sag Resistance20 minutes< in. ( mm)< in. ( mm)< in. ( mm)Open Time20 minutes at 28 days 75 psi ( Mpa) 75 psi ( Mpa) 75 psi ( MPa)PropertyDuration/ConditionsANSI RequirementResultsQuarry Tile to Plywood Shear Bond Strength7 days>100 psi ( MPa)>100 psi ( MPa)28 days>150 psi ( MPa)>150 psi ( MPa)12 weeks>150 psi ( MPa)>150 psi ( MPa) SCHLUTER ALL-SET Working Properties*Open Time20-30 minutesPot Life2-4 hoursTime to Grout12 hoursTime to Heavy Traffic24 hours*At 70 F (21 C), working properties will vary based on jobsite conditions3 SCHLUTER or less before installing SCHLUTER uncoupling membranes.

6 Follow gypsum manufacturer s directions for additional substrate clean, potable water into a clean pail. Slowly add powder while beginning to mix. For installing SCHLUTER membranes, use - qts ( - L) of water to 50 lbs ( kg) of mortar. For installation of tile, use - qts ( - L) of water to 50 lbs ( kg) of mortar. Mix at a slow speed (<300 rpm) for 5 minutes. Let the mixture slake for 10 minutes then remix at a slow speed (<300 rpm) for an additional 3 minutes. Following this procedure will produce the best workability and help ensure maximum open time and pot life. To install SCHLUTER membranes the mortar should be mixed to a fairly fluid consistency, but still able to hold a notch.

7 Do not add more water after substrate:1. Apply a thin layer of the mortar with the flat side of the trowel to produce solid contact with the substrate. 2. Using an appropriate sized notched trowel, comb additional mortar using the notched side of the trowel. Mortar ridges should run in one a. SCHLUTER -DITRA family of uncoupling membranes: solidly embed into the mortar using a float, screed trowel, or SCHLUTER -DITRA-ROLLER. When using DITRA-ROLLER, place a weight ( , bag(s) of mortar/grout or box of tile) not to exceed 75 lbs (34 kg) on the DITRA-ROLLER shelf. Slowly move the roller from one end 800-667-8746 (Canada) or by e-mail at to receive a copy of the appropriate SCHLUTER Installation Handbook for your application and a step-by-step installation video.

8 To download a PDF version of the Handbook or to view the installation video online, please visit must be acclimated to ambient conditions and installed when the ambient and surface temperatures are within a range of 40 F (4 C) to 95 F (35 C). Tenting of working area may be necessary to shade the surfaces from direct sunlight and/or rain. Direct sunlight or high temperatures may cause flash setting or skinning of the mortar. If an installation is to be completed in cold temperatures, the space must be heated before, during and after the installation to ensure proper curing of the mortar. Combustion heaters must be vented for carbon monoxide Preparation The substrate must be clean, even, and load bearing.

9 Any leveling of the subfloor must be done prior to application of SCHLUTER ALL-SET . For concrete substrates, remove any waxy or oily films and curing compounds (if present) by mechanical scarification (take steps to not breathe in any residual dust). When bonding to particularly dry, porous concrete, the slab should be moistened to saturate the concrete and help prevent premature drying or skinning of the bond coat. Excess or standing surface water must be removed prior to installation. For gypsum substrates, residual moisture in gypsum screed must be Limitations Particle board, luan, Masonite , hardwood floors, and dimension lumber are not suitable substrates for tile applications.

10 SCHLUTER ALL-SET is not designed to level floors. Any leveling or sloping of the assembly must be done with an appropriate substrate preparation material, such as Portland cement mortar, self-leveling underlayment, etc. Tile coverings are not inherently waterproof. See the SCHLUTER -Shower System Installation Handbook or the SCHLUTER -Systems Waterproofing Membranes Technical Data Sheet for details on how to create a waterproof assembly for your application. Type, thickness, and format of the tile or stone surface covering must be suitable for the intended application. Moisture-sensitive stones ( , green marble) and resin-backed tiles may require special setting materials.


Related search queries