Search results with tag "Portland cement"
MSDS: Lafarge Portland Cement Material Safety Data Sheet
www.nrc.govMar 01, 2008 · MSDS: Lafarge Portland Cement Material Safety Data Sheet Section 1: PRODUCT AND COMPANY INFORMATION Product Name(s): Product Identifiers: Lafarge Portland Cement (cement) Cement, Portland Cement, Hydraulic Cement, Oil Well Cement, Trinity® White Cement, Antique White Cement, Portland Cement Type I, lA, IE, II, 1/11, IIA, …
Division 9 Materials - Washington State Department of ...
www.wsdot.wa.govCement shall be classified as portland cement, blended hydraulic cement, or rapid hardening hydraulic cement. 9-01.2Specifications 9-01.2(1) Portland Cement Portland cement shall meet the requirements of AASHTO M85 or ASTM C150 Types I, II, or III portland cement, except that the cement shall not contain more than 0.75 percent
SAFETY DATA SHEET General Purpose Cement
www.cementaustralia.com.auOther Names: Portland Cement, Shrinkage Limited Cement*, HE (High Early) Cement*, Off White Cement, White Cement, Grey Cement, Tradies Own Type GP Cement, Sulfate Resisting Cement*, Manufacturers Cement Use: General Purpose Cement is used as a binder in concrete, concrete masonry, mortar and grouts. It is also used in the manufacture of fibre ...
Material Safety Data Sheet for cement - PPC Ltd
www.ppc.africa(iii) Chemical name : Portland cement (iv) Synonyms : Cement, Portland cement, Portland-composite ce-ment, Blastfurnace cement, pozzolanic cement and Composite cement. (v) Chemical abstract number : 65997-15-1 (vi) NIOSH number : - (vii) RTECS number : W8770000 (viii) UN number : Awaited
Safety Data Sheet Portland Cement
sacement.comPortland Cement Safety Data Sheet Portland Cement Section 1. Identification GHS product identifier: Portland Cement I, II, III, I/II, White Cement, Masonry Cement Type M, S Chemical name: Calcium compounds, calcium silicate compounds, and other calcium compounds containing iron and aluminum make up the majority of this product.
New York State Department of Transportation Approved ...
www.dot.ny.gov701-02 Masonry and Mortar Cement 701-03 Blended Portland Cement Cement Blended Portland Cement 701-04 Concrete Repair Material Concrete, Repair Materials Concrete€Repair€Material,€Portland€Cement€Based Test Method NY701-13P,C New York State Department of Transportation Cement, Blends, Pozzolan, Microsilica & HRP Sampling …
Setting of Cement - NEERAJ AGRAWAL
neerajminichemistry.weebly.com‘Ordinary Portland Cement’, the most commonly used type of cement (offered referred to as OPC). Portland cement is a basic ingredient of concrete, mortar and non specialty grout. The most common use for Portland cement is in the production of concrete. Concrete is a composite material consisting of aggregate (gravel and sand), cement and water.
IRC:15-2017 - Public.Resource.Org
law.resource.orgii) Portland-Pozzolana Cement IS:1489 (Part 1) iii) Portland Slag Cement, IS:455 iv) Composite Cement (blended with granulated slag & fly ash), IS:16415 If the soil around concrete pavement has soluble salts, like sulphates in excess of 0.5 per cent, the cement used shall be Sulphate Resisting Portland Cement, IS:12330. The limits
Solar Reflectance Values of Concrete - The Portland …
www.cement.orgportland cement, fly ash, and slag cement types. Figure 2 shows samples of the fine and coarse aggregates. Except for white portland cement, the portland cements were about the same shade of gray (Fig. 1). Individual particles of fine aggregate (typically erosion sediment largely consisting of granite, quartz, and feldspar) varied in
IS 1489-1 (1991): Specification for Portland pozzolana ...
law.resource.orgPortland-pozzolana cement shall conform to IS 3812 : 1981 subject to the requirements specified in 4.1.2 and 4.1.3. 1 4.1.2 Fineness and average compressive strength in lime reactivity of fly ash that is to be blended with finished Portland cement to produce Portland-pozzolana cement, when tested in
Concrete Mix Design Manual Rev08-19 - NCDOT
connect.ncdot.govPortland Cement (ASTM C150 /AASHTO M85) Portland cement is the most common hydraulic cement used in concrete on NCDOT projects. It is composed primarily of calcium silicates, with a smaller proportion of calcium aluminates. By definition, the composition of portland cement falls within a relatively narrow band.
C1: Portland Cement Based Concrete Products
www.quikrete.comInteraction of Portland cement with water or sweat releases a caustic solution which produces the burns or irritation. Any extended exposure should be treated as though a burn has occurred until determined otherwise. Skin contact with Portland cement can also cause inflammation of the skin, referred to as dermatitis.
IS 4032 (1985): Method of chemical analysis of hydraulic ...
law.resource.orgOct 30, 1985 · Portland cement, Portland slag cement and Portland pozzolana cement. In case of dispute or doubtful marginal values, the gravemetric methods for estimation of CaO, MgO and Al2O3 and potassium permanganate method for estimation of Fe2O3 shall be taken as referee method. For rapid complexometric methods of
Production Rates Guidelines for Arizona Highway Construction
azdot.gov4010012 Portland Cement Concrete Pavement Sq.Yd. 3,000 - 4,000 At ramp and taper locations. 4010040 Continuously Reinforced PCCP (Limited Areas) Sq.Yd. 1,000 - 3,000 4020048 Grind Existing Portland Cement Concrete Pavement Sq.Yd. 5,000 Example would be grinding a lane of travel (not a spot repair). 4020072 Repair Portland Cement Concrete Pavement
Sustainability – technical feature - BRMCA
brmca.org.ukprovided by Portland cement or the Portland cement clinker com-ponent of a factory-made composite cement. Pozzolanic or latent hydraulic additional materials, such as fly ash, silica fume and ggbs, are those that either react with, or are activated by, alkali released by the hydration of the cement to form products that contribute to strength.
3.1 CO2 Cement Production - IGES
www.ipcc-nggip.iges.or.jpMasonry cement, in contrast with Portland cement, requires additional lime. To account for this, the IPCC Guidelines provide an equation, based on masonry cement production parameters, to estimate CO2 emissions resulting from the additional lime. The equation is illustrated below. EQUATION 2 CO2 (tons) from CaO added to masonry cement =
PPPFA DESIGNATED SECTOR CIRCULAR NO. 01 OF 2021/2022 ...
ocpo.treasury.gov.zacomposite cement: slag and ash cement. Blended cements with more than one blending material All civil and building construction as appropriate 100% Masonry cement Mixture of Portland cement and plasticizing materials such as limestone to improve setting time use in mortar, brick, block, and stone masonry construction
ASTM C150: Standard Specification for Portland Cement
archive.orgThis stantklrd has been approved for lISe by agencies of tile Department of Defelise. 1. Scope' 1.1 This specification covers eight types of portland cement, as follows (see Note 2): 1.1.1 Type I-For use when the special properties specified for any other type are not required. 1.1.2 Type IA-Air-entraining cement for the same uses as
IS 2645 (2003): Integral Waterproofing Compounds for ...
www.iitk.ac.inccmcnt shall mean ordinary Portland cement 33 Grade, 43 (;rade or 53 Grade conforming to IS 269. IS 8112 and IS 12269 respectively. By agreement betweeo the purchaser and the supplier, testing of waterproofing compoonds may bc done will] Portland slag cement conforming to IS 455 or I’ortland poz,wlaoa cement- Fly ash based conforming to
jameshardie.co.nz CLD Structural Cavity Batten
www.jameshardie.co.nzPortland cement, ground sand, cellulose fibre and water. The product is easily identified by the name 'Stria Cladding' printed on the back of the panels. CLD Structural Cavity Batten is manufactured using a low density fibre cement formulation. The basic composition is Portland cement, ground sand, cellulose fibre, water and proprietary additives.
Standard Specification for Application of Portland Cement ...
www.floridabuilding.org3.2.24 stucco—portland cement-based plaster used on exte- rior locations. 3.2.25 stucco finish—a factory-prepared, dry blend of ma- terials for finish coat applications. 3.2.26 temper, v—to mix or restore unset plaster with water to a workable consistency.
Standard Specification for Mortar for Unit Masonry1
masonryinstitute.comof the portland cement content or 1 % of the masonry cement content, or both, of the mortar. NOTE 2—If calcium chloride is allowed, it should be used with caution as it may have a detrimental effect on metals and on some wall finishes. 5. Requirements 5.1 Unless otherwise stated, a cement/lime mortar, a mortar
9HUVD%RQG 3URIHVVLRQDO7KLQ 6HW0RUWDU 7'6 …
images.thdstatic.comMar 27, 2018 · Cement-based precast terrazzo Natural stone tile Suitable Substrates Concrete, mortar beds, masonry, Portland cement plaster WonderBoard Lite cement backerboard Liquid applied waterproofing membranes such as RedGard and Custom 9240 Crack prevention sheet membranes such as Crack Buster Pro
Specification for Road Works Series 500 - Drainage and ...
www.tiipublications.ie501 Pipes for Drainage and for Service Ducts General ... Concrete (With Portland Cement or sulphate-resisting cement when required in Appendix 5/1. Super-sulphated cement shall not be used) 110 Foul and surface water drains not exceeding 900mm internal diameter IS 6 or ...
Soil Cement Stabilization - Institute for Transportation
intrans.iastate.edu• Cement Treated Base (CTB) : Fully bound engineered mixture of soil/aggregate, water and sufficient Portland cement to meet the project specified minimum durability and strength requirements. CTB can be mixed-in-place using on -site soils or mixed in a central plant
DIVISION 600 MISCELLANEOUS CONSTRUCTION SECTION …
www.codot.govClass E concrete may be used for fast track pavements needing early strength in order to open a pavement to service soon after placement. Additional requirements are: Type III portland cement may be used The concrete mix shall consist of a minimum 55 percent AASHTO M 43 size No. 357 or No. 467 coarse aggregate by weight of total aggregate.
IS 516 (1959): Method of Tests for Strength of Concrete
www.iitk.ac.in-is:269-1958 specification for ordinary, rapid-hardening and low heat portland cement (revised) ·since reviled. 3. is:516 -1959 ·15 : 383·1952 specification for coarse and fine aggregates from natural sources for conckete tis: 455-1953 specification for portland blastfurnace slag * cef\fent
Construction Prequalification Work Classifications - …
www.michigan.govThis work shall consist of constructing a jointed portland cement concrete pavement, base course or shoulder, with or without reinforcement, as specified; large, road work. Equipment: Major paving equipment (slipform). Ba CONCRETE PAVEMENT PATCHING AND WIDENING (Section 603 Standard Specifications)
Schluter -Shower System Installation Handbook 2021
images.thdstatic.comPortland cement mortar bed • Base can be built for custom shower, fits any shape • Especially suited for off-set drain placement ... All penetrations must be treated with KERDI-SEAL-PS/-MV seals, KERDI-FIX or suitable sealant. When using the stainless steel KERDI-DRAIN bonding flange, use KERDI-FIX to bond KERDI to the drain.
RAMMED EARTH STRUCTURES – CODE OF PRACTICE
www.rammedearthconsulting.coma) ordinary Portland cement - see EN 197-1; b) lime or hydrated lime; c) lime combined with pozzolanas such as pulverized fuel ash and ground granulated blast furnace slag; d) cement extended with pozzolanas such as pulverized fuel ash and ground granulated blast furnace slag. e) such other stabilizer as approved by the building supervisor.
VDOT 2016 Item Code Table 071819 - Virginia Department …
virginiadot.org00182 utility test pit portland cement concrete ea attd 00190 surcharge placement & removal cy 303 00200 settlement plate ea 303 00211 minor structure excav. pipe culvert cy 303 00212 minor structure excav. box culvert cy 303 00270 select matl. ty. i …
Lime Treated Soil Construction Manual | Lime Stabilization ...
www.graymont.comconstruction; and to condition the soil (make it workable) for further stabilization with Portland cement or asphalt. Generally, between 1 and 4 percent lime will dry a wet site sufficiently to allow construction activities to proceed. Second, lime treatment can significantly improve soil workability and short-term strength to
03 35 00 - Concrete Finishing - Bay Area Rapid Transit
webapps.bart.gov3. Bond patching mortar to concrete with bonding grout or epoxy adhesive. Bonding grout shall consist of 1 part portland cement to 1 part No. 30 mesh sand, mixed to the consistency of a thick cream, and then well brushed onto the concrete. Bond commercial patching mortar to concrete in accordance with the manufacturer's instructions. 4.
7 Subgrade Construction - Indiana
www.in.gov3) Geogrid in accordance with Section 214 placed under ... Chemical modification of soils consists of uniformly mixing dry Portland cement, fly ash, lime, or a combination of the materials with soil to aid in ... Construction traffic is not allowed on the treated soils within 72 h of compaction. When selected by the Contractor, subgrade ...
PRODUCT DATA SHEET SikaTop® Armatec®-110 EpoCem®
gbr.sika.comChemical Base Portland cement, epoxy resin, selected aggregates and additives Packaging 20 kg: A (1.14 kg) + B (2.86 kg) + C (16 kg) Appearance / Colour Mixed components dark grey Component A white liquid Component B colourless liquid Component C …
1.1 REFERENCES 1.2 DEFINITIONS 1.3 SUBMITTALS 1.4 ...
www.wbdg.org3.13 CURING AND PROTECTION 3.13.1 Requirements for Type III, High-Early-Strength Portland Cement 3.13.2 Curing Periods 3.13.3 Curing Formed Surfaces 3.13.4 Curing Unformed Surfaces 3.13.5 Temperature of Concrete During Curing 3.13.6 Protection from Mechanical Injury 3.13.7 Protection After Curing 3.14 FIELD QUALITY CONTROL
Material Safety Data Sheet [OSHA 29 CFR 1910.1200]
www.quikrete.comQUIKRETE® MATERIAL SAFETY DATA SHEET page # 2 Product Types: QUIKRETE® DRY PACKAGED PORTLAND CEMENT BASED PRODUCTS (SERIES 4) MSDS E Other Limits: National Institute for Occupational Safety and Health (NIOSH).Recommended standard maximum permissible concentration=0.05 mg/M3 (respirable free silica) as determined by a full-shift …
22 Spec - 606 Riprap - Wisconsin Department of Transportation
wisconsindot.govConform to the physical requirements for component materials as specified in 501.2 except furnish ... voids. (2) Certify that the grout conforms to the following mixture requirements: - Contains 470 pounds or more of portland cement per cubic yard of grout. The contractor may substitute ... for concrete pavement.
Common Abbreviations - North Dakota Department of ...
www.dot.nd.govPortland Cement concrete PCC pounds Lb or # power pole PP preemption Preempt prefabricated Prefab preformed Prfmd or Pref or Pref preperation Prep pressure Press. pressure relief valve PRV prestressed Prestr private Pvt private drive PD production/produce Prod. programmed Prog property Prop. property line Prop Ln proposed Ppsd pull box PB ...
Reported by Committee 302 - American Concrete Institute
www.concrete.orgConcrete floor slabs employing portland cement, regardless of slump, will start to experience a reduction in volume as soon as they are placed. This phenomenon will continue as long as any water, heat, or both, is being released to the surroundings. More-over, because the drying and cooling rates at the top and bottom
IS 12089 (1987): Specification for granulated slag for the ...
law.resource.orgmixing Portland cement clinker, gypsum and granulated slag in suitable ... mixed and a composite sample of 20 kg shall be collected. 4.4 The sample of 20 kg, obtained, as under 4.3, shall be divided into two equal parts. One part shall be retained in a tightly sealed container for
CHAPTER 4. HOSPITAL HELIPORTS
www.faa.govillustrated in Figure 4-3. The landing position should have a minimum length of 1.0 times the RD of the design helicopter ... area (Paragraph 806b). Portland Cement Concrete (PCC) is recommended for ground-level facilities. ... the FATO should be treated to prevent loose stones and any other flying debris caused by rotorwash.
Chapter 2 - Incinerators and Oxidizers
www.epa.govPortland Cement RTO 502,312 dscfm 25,280,000 7,970,758 2010 Cost based on costs of an RTO installed on an existing kiln. Total capital investment includes direct (DC) and indirect costs (IC) estimated based on Cost Manual. EPA 2010 Plywood Composite - MIN
ARDEX CP
www.ardexamericas.comfilling and repairing areas of indoor and outdoor concrete above, on or below grade. Engineered with Portland cement and select high-performance polymers, ARDEX CP readily bonds to concrete surfaces. It is easy to apply, hardens quickly, is freeze-thaw resistant, and produces a surface finish that is suitable for foot and rubber tire traffic.
SANNDD//TOPPPPIINNGG MMIIXX 3 P UUC - QUIKRETE: …
www.quikrete.comQUIKRETE Sand/Topping Mix consists of a uniformly blended mixture of Portland cement and commercial grade sands, used for repairing and topping damaged horizontal concrete surfaces less than 2" (51 mm) thick. Topping 03 53 00 .
CEMENT RAW MATERIALS - International Cement Review
www.cemnet.comCEM IV Pozzolanic cement Comprising Portland cement and higher percentages of pozzolana CEM V Composite cement Comprising Portland cement and higher percentages of blastfurnace slag and pozzolana or fly ash 1.2 Deposits The availability of suitable raw materials is normally the determining factor in the location of cement works and these are ...
Portland Cement, Concrete, Volume 18/Number 2 and Heat …
www.philadelphia.edu.joPortland Cement, Concrete, and the Heat of Hydration Cement on the Go Portland Cement, Concrete, and Heat of Hydration Fig.1 demonstrates the effect of element size on concrete tempera-ture with time due to the heat of hydration. Temperature rises of 55°C (100°F) have been observed with high ce-ment content mixes.(2) These tem-
Similar queries
MSDS: Lafarge Portland Cement Material Safety Data Sheet, Portland Cement, Cement, White Cement, Division 9 Materials, Portland Cement Portland cement, SHEET, Portland-composite ce-ment, Composite cement, Safety Data Sheet Portland Cement, Portland Cement Safety Data Sheet Portland Cement, New York State Department of Transportation, Portland Cement Cement, Portland, New York State Department of Transportation Cement, Composite, Portland-pozzolana cement, Solar Reflectance Values of Concrete, Of portland cement, Portland Cement Based Concrete Products, Treated, Portland pozzolana cement, Production, Cement production, ASTM C150, Tile, CLD Structural Cavity Batten, Standard Specification for Application of Portland Cement, Specification for Road Works Series, Concrete, Cement Treated, DIVISION 600 MISCELLANEOUS CONSTRUCTION SECTION, For Strength of Concrete, Rapid, Hardening, Construction Prequalification Work Classifications, Constructing, PAVEMENT, Shower System Installation Handbook 2021, RAMMED EARTH STRUCTURES – CODE OF PRACTICE, Item Code Table, Bonding, Epoxy, Indiana, Armatec®-110, White, Curing, Material Safety Data Sheet [OSHA, QUIKRETE, SAFETY DATA SHEET, Safety, Riprap, Concrete pavement, Common Abbreviations, CHAPTER 4. HOSPITAL HELIPORTS, Repairing, Pozzolana, Ment