SECTION 4 COMMUTER FACILITIES DESIGN REQUIREMENTS

SECTION 4. COMMUTER FACILITIES DESIGN REQUIREMENTS . Architectural DESIGN Criteria : SECTION 4. COMMUTER FACILITIES DESIGN REQUIREMENTS CONTENTS. Title Rev. Date COMMUTER FACILITIES Architectural DESIGN REQUIREMENTS A3 June 15. COMMUTER FACILITIES M&E DESIGN REQUIREMENTS A2 May 13. Architectural Checklist For Bus Interchange A2 May 13. Architectural Checklist For Bus Shelter / Bus Bay A2 June 15. Architectural Checklist For Taxi / Passenger Pick-Up Shelter A2 June 15. Architectural Checklist For Pedestrian Overhead Bridge (POB) A2 June 15.

accordance with LTA Signage Design Guideline Manual, Tender Conditions and Reference Manual. The provision, layout, location and detailed design of the signage shall be carried out in consultation with LTA. (c) For bus interchange which is in the vicinity of residential housing, noise mitigation measures shall be provided, unless otherwise stated.

Tags:

  Tender

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SECTION 4 COMMUTER FACILITIES DESIGN REQUIREMENTS

1 SECTION 4. COMMUTER FACILITIES DESIGN REQUIREMENTS . Architectural DESIGN Criteria : SECTION 4. COMMUTER FACILITIES DESIGN REQUIREMENTS CONTENTS. Title Rev. Date COMMUTER FACILITIES Architectural DESIGN REQUIREMENTS A3 June 15. COMMUTER FACILITIES M&E DESIGN REQUIREMENTS A2 May 13. Architectural Checklist For Bus Interchange A2 May 13. Architectural Checklist For Bus Shelter / Bus Bay A2 June 15. Architectural Checklist For Taxi / Passenger Pick-Up Shelter A2 June 15. Architectural Checklist For Pedestrian Overhead Bridge (POB) A2 June 15.

2 Architectural Checklist For Pedestrian Underpass A2 June 15. Architectural Checklist For Covered Linkway A2 June 15. Architectural Checklist For Covered Walkway A2 June 15. Attached Drawings: Bus Interchange L/CFADC/AR/BI/0001-0014. Bus Shelter / Bus Bay APPENDIX B1- B6. Taxi / Passenger Pick-Up Shelter APPENDIX T1- T7. COMMUTER FACILITIES M&E REQUIREMENTS L/ROAD/MES/SD/1001-2001. Jun 2015 Architectural DESIGN Criteria Revision A4. LTA Architectural DESIGN Criteria: SECTION Page-1/19. COMMUTER FACILITIES Architectural DESIGN REQUIREMENTS CONTENTS.

3 1 INTRODUCTION .. 3. 2 BUS INTERCHANGE/ TERMINAL .. 4. General .. 4. Overview .. 4. Statutory REQUIREMENTS and LTA REQUIREMENTS / Guidelines .. 4. Studies and Submissions .. 4. DESIGN Principles and Considerations .. 4. Bus Park Area .. 5. Overview .. 5. Bus Interchange Simulation Study and Bus Trials .. 6. Bus Ingress & Egress .. 6. Bus Parking Lots .. 6. Driveway .. 7. Boarding/ Alighting Berths .. 7. Safety Provisions .. 7. DESIGN and Finishes .. 8. Concourse 8. Overview .. 8. COMMUTER Accessibility .. 8. Air-conditioned Bus Interchange.

4 8. Walls, Doors and Shutters .. 9. Finishes .. 9. Non air-conditioned Bus Interchange .. 9. Roof .. 9. Finishes .. 9. Queue Rails and Boarding/ Alighting 9. Seating Benches ..10. Information Panel Boards ..10. Offices and Other FACILITIES ..10. Overview ..10. Minimum Size of Offices and Other FACILITIES ..11. Passenger Service Offices ..11. Staff Lounge cum Briefing Room ..12. Ticket Office ..12. Add Value Machine Room ..12. Commercial Space ..12. Canteen, Kitchen and Rodent-Free Store ..12. Server Room ..13. Staff and Public Toilet FACILITIES .

5 13. Bin Centre/ Point and Electrical Substation (Outside Concourse) ..13. Bicycle Parking Racks (Outside Concourse) ..13. First Aid Room cum Nursing Room ..13. Special Purpose Room ..14. 3 BUS BAYS ..15. DESIGN of Bus Bay ..15. Sizing of Bus bay ..15. June 2015 SECTION of Architectural DESIGN Criteria Revision A3. Page-2/19. 4 SHELTERS ..16. General ..16. Bus shelters ..16. Bus Shelter Elements .. 16. Bus Shelter Signage ..17. Taxi /passenger pickup shelters ..17. Taxi Shelter Elements ..17. Taxi Shelter Signage ..17. Pedestrian Overhead Bridge Shelters.

6 17. Linkway Shelters ..17. 5 PEDESTRIAN OVERHEAD BRIDGE AND PEDESTRIAN UNDERPASS ..19. Location ..19. Provisions ..19. Pedestrian Overhead Bridge Detailing ..19. Pedestrian Underpass Detailing ..19. June 2015 SECTION of Architectural DESIGN Criteria Revision A3. Page-3/19. 1 INTRODUCTION. This document outlines the DESIGN REQUIREMENTS applicable to COMMUTER FACILITIES (CF) architectural works. It shall be incorporated along with Sections 1 and 2 of the ADC, the relevant CF Checklists, CF. E&M DESIGN REQUIREMENTS and any site specific DESIGN constraints to form part of the DESIGN brief for a particular project.

7 June 2015 SECTION of Architectural DESIGN Criteria Revision A3. Page-4/19. 2 BUS INTERCHANGE/ TERMINAL. General Overview (a) References shall be made to Drawings L/CFADC/AR/BI/0001-0013 when using this document. (b) This document shall apply to all temporary and permanent bus interchanges and bus terminals (collectively named as bus interchange), unless otherwise exempted, with the written approval from LTA. (c) An integrated bus interchange is one that is built as an integral part of a larger development. (d) A standalone bus interchange is one that is not enclosed, with natural ventilation for the concourse and bus park area.

8 Statutory REQUIREMENTS and LTA REQUIREMENTS / Guidelines (a) Internal and external road elements, including but not limited to, traffic signs, road markings, road humps, thermoplastic markings, signalisation, pedestrian crossings, vehicular impact guardrails, impact bollards, etc shall comply with the latest LTA Standard Details of Road Elements (SDRE) REQUIREMENTS . (b) Comprehensive Public Transit Signage System plan, within the bus interchange and its vicinity including the new development, shall be developed, designed and provided in accordance with LTA Signage DESIGN Guideline Manual, tender Conditions and Reference Manual.

9 The provision, layout, location and detailed DESIGN of the signage shall be carried out in consultation with LTA. (c) For bus interchange which is in the vicinity of residential housing, noise mitigation measures shall be provided, unless otherwise stated. (d) In addition to NParks' green buffer requirement, additional landscaping in and around the bus interchange shall be provided, unless otherwise stated. Studies and Submissions (a) The following studies and reviews shall be carried out and submitted by a specialist/ traffic consultant/ qualified persons to the Authority for approval prior to the finalisation of the bus interchange DESIGN and layout: i.

10 Traffic Impact Assessment (TIA), unless otherwise specified by the Authority;. ii. Traffic Scheme/ Plan, mandatory for all bus interchanges;. iii. Security Consultancy Study, for bus interchange classified as National Critical Infrastructure or Key Installation if required by the Authority;. iv. Acoustic Study, mandatory for integrated bus interchange;. v. Bus Interchange Simulation Study, mandatory for all bus interchanges;. vi. Project Safety Review PSR (Roads) by a qualified independent safety reviewer, mandatory for all bus interchanges.