In This Section Respiratory Protection In This Section Disposable Respirators .. 66-73. Respirators for Dusty Conditions.. 66-68. Welding-Approved Respirators .. 69. Respirators for Oily Conditions .. 70-71. Half-Mask Respirators .. 73. Air Purifying Reusable Respirators 74-81. Supplied Air Systems .. 82-84. Powered Air Purifying Respirators (PAPR) .. 84-85. Domestic Preparedness Respirators .. 86. SCBA .. 87. Fit Testing Supplies .. 88. Select A Respirator in 4 Simple Steps 1 3. First, Identify the Contaminants Next, Choose a Level of Protection You're Dealing With Select a filter that is designed to remove The primary source of information on a chemical's state airborne particulates which may be harmful and physical form is the Material Safety Data Sheet to the lungs in your workplace.

Cool Flow™ Exhalation Valve Adjustable Straps Cake-Resistant Filter Media Conformable Noseclip Advanced Electret Media Welding Approved Respirators The use of N-Series Respirators is typically limited only by hygiene,

Tags:

  Media, Step, Simple, Select, Respirator, Electret, Select a respirator in 4 simple steps, Electret media

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Select A Respirator in 4 Simple Steps 3 - MATHESON

1 In This Section Respiratory Protection In This Section Disposable Respirators .. 66-73. Respirators for Dusty Conditions.. 66-68. Welding-Approved Respirators .. 69. Respirators for Oily Conditions .. 70-71. Half-Mask Respirators .. 73. Air Purifying Reusable Respirators 74-81. Supplied Air Systems .. 82-84. Powered Air Purifying Respirators (PAPR) .. 84-85. Domestic Preparedness Respirators .. 86. SCBA .. 87. Fit Testing Supplies .. 88. Select A Respirator in 4 Simple Steps 1 3. First, Identify the Contaminants Next, Choose a Level of Protection You're Dealing With Select a filter that is designed to remove The primary source of information on a chemical's state airborne particulates which may be harmful and physical form is the Material Safety Data Sheet to the lungs in your workplace.

2 Particulates (MSDS). The MSDS may also make recommendations for which may be blocked by a filter include dust, what type of Respirator may be needed to work safely with the product. fumes (metal particles from welding), fibers and mists. Once the potential contaminants are identified, air sampling should be Dry particulates can be removed with an N95, N99 or N100. done to determine how much of the contaminant is likely filter. Dry or oily particulates can be removed with an R95, to be present in a work shift. R99, P95, P99, or P100 filter. 2 Then, Test Your Environment You may even need a cartridge and a filter, depending on the nature of your work.

3 Cartridges contain activated Air sampling can be performed charcoal which can be chemically treated to remove by a consulting firm or by OSHA various gases and have several types of Consultation. This evaluation cartridges to Select from. Certain chemicals will not be should include a reasonable blocked by the cartridges and you may need to consider estimate of employee exposures to a supplied air system. respiratory hazards and an 4. identification of the contaminant's chemical state and physical form. Finally, Size Your Respirator A mask must fit properly and be fit tested to Once the contaminant level is established, ensure complete protection.

4 It should have a you should investigate effective hazard control tight seal around the nose and mouth to prevent methods, such as engineering and leakage. We offer a administrative controls, before resorting complete line of Fit Test Kits to a Respirator . If you do need a to assist you with this Respirator , our trained staff can help process. Remember that you make the appropriate choice. all persons who wear respirators for a If the employer cannot identify chemical hazard must or reasonably estimate the conform with the OSHA. employee exposure, the employer requirements, which shall consider the atmosphere to includes fit testing and be IDLH (Immediately Dangerous medical evaluations.)

5 To Life and Health). For assistance determining which Respirator , Filter or Cartridge you need, call us today. 877-684-4427 65. Respiratory Protection Air Purifying Conformable Nose Clip Respirators for Dusty Conditions Cool Flow . Exhalation Valve The use of N-Series Respirators is typically limited only by hygiene, damage and increased breathing resistance. However, when working in very dirty or dusty Three Panel workplaces that may result in high filter loading (200 mg), service time should be limited to 8 hours of continuous or intermittent use, unless an evaluation is done to prove that extended use will not significantly degrade efficiency levels.

6 Advanced electret media When choosing a Respirator for Dusty Conditions, consider the following features: 3M Cool Flow Exhalation Valve A patented one-way valve for easy exhalation and cool, dry comfort. Conformable Noseclip Standard (S) or M-Noseclip (M). adjusts easily for fewer pressure points. Advanced electret media Advanced electrostatically- charged microfibers make breathing easier and cooler. Three Panel Designed for comfort and convenience. 3M Particle Respirator 8200, N95 3M Particulate Respirator 8210, N95. 9210. 9211. 3M Particulate Respirator 8511, N95 3M Vflex 9105, N95 3M Particulate Respirator 9210/9211, N95.

7 Advanced NIOSH Exhale electret Three CSP# 3M# Applications Rating Valve Noseclip media Panel Quantity 1-7 8+. Workplace applications include bagging, grinding, sanding, sawing, 50034 8200 sweeping, woodworking and other dusty applications. N95 S 20/Box $ Workplace applications include bagging, sanding, sweeping, 70005 8210 sawing and polishing. N95 S X 20/Box Same approvals as #70005, but made for workers with smaller 80646 8110S faces. N95 S X 20/Box Workplace applications include grinding, sanding, sweeping, 70011 8511 bagging, general maintenance and other dusty operations. N95 X M X 10/Box Flat-fold style allows for convenient storage prior to use.

8 V-shaped pleats flex with mouth movement for easier talking. Workplace 51115 9105 applications include grinding, sanding, sweeping, bagging, general N95 S X X 50/Box maintenance and other dusty operations. Workplace applications include grinding, sanding, sweeping, 53149 9210 bagging, general maintenance and other dusty operations. N95 S X X 20/Box Workplace applications include grinding, sanding, sweeping, 53150 9211 bagging, general maintenance and other dusty operations. N95 X S X X 10/Box Fact Respirator Selection Process The three categories of resistance to the effects of oil are: Under NIOSH 42 CFR 84 there are nine classes of filters comprised N Not resistant to oil of three levels of minimum filter efficiency and three categories of R Resistant to oil resistance to the effects of oil in the workplace.

9 P Oil proof The three different levels of filtration efficiency are 95%, 99% and (100) against the most difficult particle size to filter. For assistance in selecting the correct Respirator , call our Technical Support Team today. 66 877-684-4427. Air Purifying Respiratory Protection Molded Nose Respirators for Dusty Conditions Bridge The use of N-Series Respirators is typically limited only by hygiene, damage and increased breathing resistance. However, when working in very dirty or dusty Exhalation Valve workplaces that may result in high filter loading (200 mg), service time should be limited to 8 hours of continuous or intermittent use, unless an evaluation is done Adjustable Strap to prove that extended use will not significantly degrade efficiency levels.

10 All Moldex Respirators come standard with several features. Dura-Mesh shell Flame-Retardant resists collapsing in heat and humidity. Softspun lining offers increased comfort Shell and durability. When choosing a Respirator for Dusty Conditions, also consider the Fully Adjustable Straps Adjustable Straps (A) provide a secure following features: fit with a single tug. HandyStraps (HS) with buckle allow mask to hang down when not in use. Exhalation Valve Lets the hot air out faster so workers can breathe easier. Foam Nose Cushion Soft foam face cushions provide added comfort and no pressure points. Molded Nosebridge Seals without a metal noseband.