Example: confidence

Sensors & Accessories Compatible with E-2D/5D/16D

2013, 2018 NTI. All rights TECHNOLOGIES ( )Toll Free: US & SensorsSensors & Accessories Compatible with E-2D/5D/16 DENVIROMUX Temperature & Humidity SensorsE-STHSB Temperature/Humidity/Dew Point sensor Applications from -4 to 140 F (-20 to 60 C) and 0% to 90% relative humidity. Temperature accuracy: F ( C) for -4 to 14 F (-20 to -10 C). F ( C) for 14 to 140 F (-10 to 60 C). Humidity accuracy:Temperature/Humidity/Dew Point Combination sensor E-STHS-PRCLow-Cost Precision Temperature/Humidity sensor Applications from 14 to 140 F ( -10 to 60 C) and 10 to 80% relative humidity. Accurate to within F ( C) and relative humidity. Supports dew point measurementE-STHSB-DTemperature/Humidity /Dew Point sensor , DIN Mounted Applications from -4 to 140 F (-20 to 60 C) and 0 to 90% relative humidity. Temperature accuracy: F ( C) for -4 to 14 F (-20 to -10 C). F ( C) for 14 to 140 F (-10 to 60 C).

TECHNOLOGIES ® • relay.

Tags:

  Sensor

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Sensors & Accessories Compatible with E-2D/5D/16D

1 2013, 2018 NTI. All rights TECHNOLOGIES ( )Toll Free: US & SensorsSensors & Accessories Compatible with E-2D/5D/16 DENVIROMUX Temperature & Humidity SensorsE-STHSB Temperature/Humidity/Dew Point sensor Applications from -4 to 140 F (-20 to 60 C) and 0% to 90% relative humidity. Temperature accuracy: F ( C) for -4 to 14 F (-20 to -10 C). F ( C) for 14 to 140 F (-10 to 60 C). Humidity accuracy:Temperature/Humidity/Dew Point Combination sensor E-STHS-PRCLow-Cost Precision Temperature/Humidity sensor Applications from 14 to 140 F ( -10 to 60 C) and 10 to 80% relative humidity. Accurate to within F ( C) and relative humidity. Supports dew point measurementE-STHSB-DTemperature/Humidity /Dew Point sensor , DIN Mounted Applications from -4 to 140 F (-20 to 60 C) and 0 to 90% relative humidity. Temperature accuracy: F ( C) for -4 to 14 F (-20 to -10 C). F ( C) for 14 to 140 F (-10 to 60 C).

2 E-STST emperature sensor Applications from 32 to 122 F (0 to 50 C). Accurate to within F ( C). High resistance to external influences on the cable due to digital output Temperature & Combination SensorE-STSM-E7E-STHSM-E7 Temperature sensor (E-STSM-E7) Applications from -4 to 140 F (-20 to 60 C). Temperature accuracy: F ( C) for -4 to 41 F (-20 to 5 C). F ( C) for 41 to 140 F (5 to 60 C). Temperature/Humidity sensor (E-STHSM-E7 Applications from -4 to 140 F (-20 to 60 C) and 0 to 90% relative humidity. Temperature accuracy: F ( C) for -4 to 14 F (-20 to -10 C). F ( C) for 14 to 140 F (-10 to 60 C). Humidity accuracy: 0 to 80% relative humidity, 3% 80 to 90% relative humidity, 4% Supports dew point measurement Length: 7 feet. Includes an RJ45 coupler to extend the sensor up to 1000 feet (305 m) using CATx cable (minimum 24 AWG). 0 to 80% relative humidity, 3% 80 to 90% relative humidity, 4% Supports dew point measurement.)

3 Supports CAT5/5e/6/6a cable (24 AWG) up to 1,000 ft (305 m) (not included). Humidity accuracy: 0 to 80% relative humidity, 3% 80 to 90% relative humidity, 4% Supports dew point measurement. DIN mountableE-STHS-LCDWT emperature/Humidity sensor with 3-Digit 7-Segment LCD Display 2 Character Height Use to detect and view real-time value of the sensor s temperature or humidity reading. Three-digit, seven-segment display with F, C and % indicators. Applications from -4 to 140 F (-20 to 60 C) and 0 to 90% non-condensing relative humidity. Temperature accuracy: F ( C) for 14 to 140 F (-10 to 60 C). F ( C) for -4 to 14 F (-20 to -10 C). Humidity accuracy: 0 to 80% relative humidity, 3% 80 to 90% relative humidity, 4% 2013, 2018 NTI. All rights TECHNOLOGIES ( )Toll Free: US & SensorsSensors & Accessories Compatible with E-2D/5D/16 DENVIROMUX Pipe Temperature SensorE-STSP-7 Mount to the outside of a thin walled steel, copper, or aluminum pipe (up to 1/4" wall).

4 Copper contact transmits surface temperature to thermal sensor . Weatherproof enclosure designed to IP65 specifications. Applications from -40 to 185 F (-40 to 85 C). Accurate to within F ( C). Response time: <1 minute for temperature changes of 2 F. Length: 7 feet. Includes an RJ45 coupler to extend the sensor up to 1,000 feet using CATx cable (minimum 24 AWG).Strap-On Pipe Temperature sensor , Spring-LoadedE-STSP-SL-7 Mount to the outside of an insulated metal pipe (up to 1/4 wall). Copper contact transmits surface temperature to thermal sensor . Spring-loaded contact enables minimal removal of pipe insulation. NEMA 1 and IP20 rated metal enclosure Applications from -40 to 185 F (-40 to 85 C). Accurate to within F ( C). Response time: <1 minute for temperature changes of 2 F. Length: 7 feet. Includes an RJ45 coupler to extend the sensor up to 1,000 feet using CATx cable (minimum 24 AWG).

5 Temperature & Humidity Sensors (continued)Industrial Temperature/Humidity sensor -40 to 185 F (-40 to 85 C)E-STHSB-N4085 IND-x Applications from -40 to 185 F (-40 to 85 C) and 0 to 100% non-condensing relative humidity. Accuracy: F ( C) at 14 to 185 F (-10 to 85 C) F ( C) at -40 to 14 F (-40 to -10 C)RTD Temperature Transmitters100 Ohm Platinum RTD TransmitterE-RTDT-140E-RTDT-240 Available temperature ranges: E-RTDT-140: -20 to 140 F (-28 to 60 C). E-RTDT-240: 30 to 240 F (-1 to 115 C). Accurate to within F ( C). Configuration: 2-wire connection sensor Element: 100 platinum Signal Output: 4-20 mA, loop-powered Requires the E-S420MA and an RTD sensor probe to operate with the E-2D/5 Platinum RTD Transmitter, -328 to 1562 FE-RTDT-1562 Temperature range: -328 to 1562 F (-200 to 850 C) Accurate to within F ( C) Configuration: 2, 3, or 4-wire connection Signal Output: RS485 Requires an RTD sensor probe to operate with the E-2D/5D/16D .

6 3% relative humidity at 0 to 80% non-condensing RH and 86 F (30 C) relative humidity at 80 to 100% non-condensing RH and 86 F (30 C) Available lengths for attached CAT5e cable: 10/25/50/100 feet. 2013, 2018 NTI. All rights TECHNOLOGIES ( )Toll Free: US & Liquid Detection sensor , Rope-StyleE-LD-LCx-y Detects any conductive liquid or moisture. Minimum puddle: ( mm) diameter. Available water sensor cable (x) lengths: 1/10/50/100/200/400/600 feet. Material: PVC twisted pair with stainless 316 elements Diameter: ( mm) Available 2-wire cable (y) lengths: 5/10/20/50/100 Detection sensor , Plenum Rope-StyleE-LDx-y Detects any conductive liquid or moisture. Minimum puddle: (15 mm) diameter. Detects liquid depth > ( mm). Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet. Plenum rating: CL2P (UL) Diameter: in ( ) Available 2-wire plenum cable (y) lengths: 5/10/20/50/100 Encapsulated 100 Ohm RTD sensor , -30 F to 230 FE-RTDS-ER230 round, long housing.

7 Applications from -30 F to 230 F (-34 C to 110 C). Accurate to within F ( C). 100 Ohm Pt 385 curve. 8 feet, 24 AWG 2-wire leads Requires the E-RTDT-140/240 and E-S420MA-24V to operate with the E-2D/5 100 Ohm RTD sensor , -58 to 392 FE-RTDS-A392 6 ft ( m) 3-wire lead with 13 (330 mm) lead wires and 1/3 (8 mm) stripped ends. One white, two red. Requires the E-RTDT-1562 to operate with the E-2D/5D/16D . Rugged, point-sensitive waterproof sensor with ( mm) round and 6 (152 mm) long stainless steel probe. Applications from -58 to 392 F (-50 to 200 C). Accurate to within 1 F ( C). 100 Ohm Pt 385 curve. Includes 15 ft ( m) extension SensorsSensors & Accessories Compatible with E-2D/5D/16 DENVIROMUX Encapsulated 100 Ohm RTD sensor , 35 F to 140 FE-RTDS-E140 round, long housing. Applications from 35 F to 140 F (2 C to 60 C). Accurate to within F ( C). 100 Ohm Pt 385 curve.

8 8 feet, 24 AWG 2-wire leads Requires the E-RTDT-140/240 and E-S420MA-24V to operate with the E-2D/5 100 Ohm RTD sensor , -67 F to 240 FE-RTDS-D240 Rugged, waterproof sensor with 9 (229 mm) 304 stainless steel probe with 4 (102 mm) electrical strap and a nylon fitting. Nylon fitting with 1/2 NPT female thread. Applications from -67 to 240 F (-55 to 115 C). Accurate to within F ( C). 100 Ohm Pt 385 curve. Requires the E-RTDT-140/240 and E-S420MA-24V to operate with the E-2D/5 100 Ohm RTD sensor , -67 F to 221 FE-RTDS-A221 Rugged, point-sensitive waterproof sensor with 9 (229 mm) 304 stainless steel probe and brass fitting. Brass fitting with 1/2 NPT male thread. Applications from -67 to 221 F (-55 to 105 C). Accurate to within F ( C). 100 Ohm Pt 385 curve. Requires the E-RTDT-140/240 and E-S420MA-24V to operate with the E-2D/5 Probe 100 Ohm RTD sensor , -67 F to 240 FE-RTDS-MP240 ( mm) round x (13 mm) long stainless steel housing.

9 Applications from -67 to 240 F (-55 to 115 C). Accurate to within F ( C). 100 Ohm Pt 385 curve. Requires the E-RTDT-140/240 and E-S420MA-24V to operate with the E-2D/5 Temperature Sensors Liquid & Chemical Detection Sensors 2013, 2018 NTI. All rights TECHNOLOGIES ( )Toll Free: US & SensorsSensors & Accessories Compatible with E-2D/5D/16 DENVIROMUX Spot Liquid Detector, Point Leak Detection SensorE-LD-SPDT Features gold-plated probes and microchip technology for dependable detection of conductive liquids. Adjustable detection level. Probe height adjustable 0 to (0 to 38mm)E-SLDO-14 Use to detect fluids in confined areas. One generic relay output Adjustable detection level. Probe height adjustable 0 to (0 to 19mm) Cable length: 14 feetCompact-Size Spot Liquid Detector, Point Leak Detection SensorE-SLDO-A Use to detect conductive fluids in confined areas Water level detection range: to " ( to 13 mm).

10 Audible alarm signal: 85 dB at 1 foot distance. Red LED for visual alarm signal. Cable length: ft ( m).Spot Liquid Detector with Built-In Visual & Audible AlarmChemical Detection SensorE-CDx-y For detecting the presence of chemical liquid. Reliably senses acids, bases, and other conductive liquids. Detects liquid depth > ( mm). Minimum puddle: (15 mm) diameter. Available chemical sensor cable (x) lengths: 1/10/50/100 feet. Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Under Carpet Leak DetectorE-UCLD-x Use to detect conductive fluids and moisture under carpets. Available 2-wire plenum cable lengths: 10/25/50/100/200/400/600/1000 & Chemical Detection SensorsAll-Purpose 100 Ohm RTD sensor , -58 to 392 FCapacitive Chemical Spot Leak DetectorE-SCD-CAP-5M Use to detect liquids in confined areas, such as in drip pans. Capacitive sensor is ideal for monitoring liquids with low conductivity, such as pure water, diesel fuel, acetic acid, ethanol, methanol, liquid ammonia, and carbohydrate solution.