Transcription of Si PHOTODIODE - Eunil Won
1 Si PHOTODIODESOLIDSTATEDIVISIONSi PHOTODIODE for precision photometry and analytical instrumentFor UV to near IR range:UV sensitivity enhanced typeSpectrophotometer, analytical instrument environmental measurement,medical instrumentCopier, optical power meter, laboratory equipment, banking machineAnalytical instrument, UV monitorS1336/S1337 series 400 600 800 1000 1200 Spectral response range (nm)FeatureApplication exampleType UV to near IR range:UV sensitivity enhanced type (with suppressed IR sensitivity)S1226/S1227 series to near IR range:IR sensitivity enhanced typeS2386/S2387 seriesS2684-254, S9050 Semiconductor production instrumentFor excimer laser (193 nm) detectionFor monochromatic light (254 nm)S8551, S8552, S8553,S90893 Photometric device, illuminometerFor visible rangeS9219 series, S7686Si PHOTODIODE for general photometry and camera applicationFor visible rangeCamera application (exposure meter, illuminometer, auto strobe)
2 , light dimmer, copierWhite balance adjustment, color identificationCopier, illuminometer, light dimmerS1087, S5493-01, visible to near IR rangeS4797-01, S1787-08, monochromatic lightS6428/S6429/S6430-01S7505-01, S9032-02.
3 14610121416171818192224252728Si PHOTODIODE for precision photometry and analytical instrumentSi PHOTODIODE for general photometry and camera applicationSi PIN photodiodeSi PHOTODIODE arraySi PHOTODIODE with preamp, TE-cooled type Si photodiodeSi APD (avalanche PHOTODIODE )X-ray detectorDescription of terms Characteristic and use 1.
4 Principle of operation2. Si PHOTODIODE 3. Si PIN photodiode4. Si PHOTODIODE with preamp5. Si APDR eliabilityPrecaution for usePage200 400 600 800 1000 1200 Spectral response range (nm)FeatureApplication exampleType PIN photodiodeCut-off frequency: 500 MHz or moreOptical fiber communication,High-speed photometryFor high energy physicOptical fiber communication,analytical instrument,optical power meterS8314, S5973-01, S9055, frequency:100 MHz to less than 500 MHzCut-off frequency:10 MHz to 100 MHzS2506-02, S5106, , S5971, laser detection,Analytical equipment, YAG laser detectionLarge active areaS3590-01, detection,laser beam alignmentS2721-02, PHOTODIODE with preamp, TE-cooled type Si photodiodeSi PHOTODIODE with preampLow-light-level measurement, NOx sensorSpatial light transmissionOptical fiber communication, video signal transmission, optical disk pickupS9269, S9270, S9295 seriesS8745-01, S8746-01TE-cooled type SiphotodiodeSi PIN PHOTODIODE with preamp for optical fiber communicationS6468 seriesSi PIN PHOTODIODE with preamp for spatial light transmissionS7516 seriesS2592/S3477 series1213X-ray detectorPhotodiode coupled to high-sensitivity X-ray scintillatorX-ray region from several ten keV to 100 keVBaggage inspection system, non-destructive inspection systemS8559, S8193,S5668 series, S787816Si APD (avalanche PHOTODIODE )
5 Low-light-level measurement, laser beam alignmentLow-light-level measurement, analytical instrumentSpatial light transmission, Rangefind-er, Optical fiber communicationLow bias operation typeShort wavelength typeS5343, S5344, S5345S8664 series, to S2385, temperature coefficient typeS6045 series1415 Multi-element typeS4402Si PHOTODIODE arrayUV to near IR range:UV sensitivity enhanced typeSi PIN PHOTODIODE array (1)Si PIN PHOTODIODE array (2)Multichannel spectrophotometer, color analyzerS4111/S4114 series, laser detection,Long wavelength light detectionLong wavelength typeS8890 series40011003201060320106011 Incident angle detection of infrared LED and sunlightIncident light angle sensorS65607601100 High-speed 2D photometry, 2D spec-trophotometry, 3D shape measurementS7585, S38053201000 These Si photodiodes have sensitivity in the UV to near IR range. The BQ type delivers high sensitivity exceeding A/W in the UV range. Other features include low dark current, low terminal capacitance and low noise, making these photodiodes ideal for precision photometry such as analytical instrument.
6 The BU type is designed to provide enhanced reliability in detecting high power UV light such as from mercury response (typical example)nDark current density (per unit active area) vs. reverse voltage * When connected to C2719 photosensor amplifier (using E2573 BNC-BNC coaxial cable), low level photocurrent can be amplified with low responserange(nm)Peak sensitivitywavelength(nm)Active area(mm)Dark currentVR=10 mVMax.(pA)PackageS1336-18 BUTO-18S1336-18BQ190 to 1100S1336-18BK320 to to 1100TO-5S1336-5BK320 to to 1100S1336-44BK320 to to 1100TO-8S1336-8BK320 to to 1100 CeramicS1337-16BR320 to to 1100S1337-33BR320 to to 1100S1337-66BR320 to to 1100S1337-1010BR320 to 1100200S6337-01190 to 110096018 1810 101000S2551320 to * BNCconnectorS2281-04 *190 to 1100960 PHOTODIODE for precision photometry and analytical instrument12356781091112 For UV to near IR range: UV sensitivity enhanced SENSITIVITY (A/W)1904006008001000 WAVELENGTH (nm) (Typ.)
7 Ta=25 C) VOLTAGE (V)DARK CURRENT/ACTIVE AREA (pA/mm2)S2387-1010RS1227-1010 BQS1337-1010BQ(Typ. Ta=25 C)1 Featuring high sensitivity and low dark current, these Si photodiodes are specifically designed for precision photometry in a wide range of fields. These Si photodiodes have suppressed IR sensitivity. The BQ type delivers high sensitivity exceeding A/W in the UV range. Since the dark current is greatly reduced, these photodiodes are ideal for low-light-level detection. The BU type is designed to provide enhanced reliability in detecting high power UV light such as from mercury Si photodiodes offer enhanced sensitivity especially in the near IR range. Low dark current and excellent linearity make these photodiodes suited for use in optical power meters and other photometric responserange(nm)Peak sensitivitywavelength(nm)Active area(mm)Dark currentVR=10 mVMax.
8 (pA)PackageS1226-18 BUS1226-18BQ190 to 1000S1226-18BK320 to to 1000S1226-5BK320 to to 1000S1226-44BK320 to to 1000S1226-8BK320 to to 1000S1227-16BR320 to to 1000S1227-33BR320 to to 1000S1227-66BR320 to to 1000S1227-1010BR320 to 100010 1050 CeramicS2281-01190 to 1000720 BNC connectorType responserange(nm)Peak sensitivitywavelength(nm)Active area(mm)Dark currentVR=10 mVMax.(pA) 10200S2387-130R320 to PHOTODIODE for precision photometry and analytical instrument123567811142356789123456781091 112 For UV to near IR range: UV sensitivity enhanced type (with suppressed IR sensitivity)Visible to near IR range: IR sensitivity enhanced type 2 Type (without window)TO-8S8553 Photo sensitivityl =193 nm(A/W) area(mm) 1018 18 Dark currentVR=10 mVMax.(nA) (without window)Type sensitivitywavelength(nm)Active area(mm)Dark currentVR=10 mVMax.
9 (pA)PackageS2684-254S9050254322 Sensitivity wavelengthspectral width(nm) (nA) responserange(nm)Peak sensitivitywavelength(nm)Active area(mm)Dark currentVR=10 mVMax.(pA)PackageS9219 BNC connectorS9219-0S7686* VR=1 V1 550 *TO-5 CeramicKSPDB0196 EBKSPDB0188 EBSi PHOTODIODE for precision photometry and analytical instrumentThese Si photodiodes are specially optimized for excimer laser detection (ArF: 193 nm, KrF: 248 nm): sensitive in the vacuum UV (VUV) range. Compared to conventional types, these photodiodes exhibit little deterioration in sensitivity from VUV exposure, allowing stable measurement over long periods of is also available with a quartz glass window or MgF2 is highly sensitive only to monochromatic light using an interference filter. The spectral response width is as narrow as 10 nm (FWHM), allowing accurate measurement without effects from stray light.
10 S2684-254 has its peak sensitivity at 254 nm Typ. Other types having the peak sensitivity at different wavelengths such as 340, 405, 500, 520, 560, 650 and 700 nm are also available upon Si photodiodes have a visual-compensated filter to provide spectral response characteristics similar to the human eye. S9219 is assembled in a metal package with a BNC response (S9219 series, S7686)nVariation in sensitivity due to UV exposure (S8551, S8552, S8553)1236674574588 For excimer laser detectionFor monochromatic lightFor visible range123 WAVELENGTH (nm)(Typ. Ta=25 C)PHOTO SENSITIVITY (A/W) SERIES 3380 to 780 NEWNEWNEWNEWCONVENTIONAL TYPERELATIVE SENSITIVITY (%)NUMBER OF SHOT[Typ. ArF excimer laser, mJ/cm2/pulse, f=100 Hz, =193 nm, pulse width=15 ns (FWHM)]5 10601 10740206080100120S8551, S8552, S85534123 Type responserange(nm )Peak sensitivitywavelength(nm )Active area(mm)Dark currentVR=1 VMa x.