SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS

DESCRIPTIONYORK Sunline 2000 units are convertible SINGLE PACKAGE airconditioners with a common cabinet and a common roof curbfor the 3, 4, 5 and 6 ton sizes. The units were designed for lightcommercial and commercial applications. They can easily beinstalled on a roof curb, slab, roof jack or units are self-contained and assembled on rigid fullperimeter base rails with fork lift slots on three sides and holesfor overhead rigging. Every unit is completely piped, wired,charged and tested at the factory to provide for a quick andeasy field units are available in cooling only, and cooling with gas heaters are available as field-installed cabinet is constructed of galvanized steel, painted with longlasting, durable, and aesthetically pleasing power paint. Paintfinish meets 750 hour salt spray tests per ASTM-B117 models include a 5-year limited warranty on scrollcompressors and electric heating elements, a 10-year limitedwarranty on gas-fired heat exchangers and a 1-year limitedwarranty on all replacement FOOTPRINT/COMMON CABINET - All modelsizes and configurations share a common cabinet and acommon roof curb.

DESCRIPTION YORK Sunline 2000 units are convertible single package air conditioners with a common cabinet and a common roof …

Tags:

  Unit, Single, Conditioners, Packages, Air conditioners, Single package, Single package air conditioners

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS

1 DESCRIPTIONYORK Sunline 2000 units are convertible SINGLE PACKAGE airconditioners with a common cabinet and a common roof curbfor the 3, 4, 5 and 6 ton sizes. The units were designed for lightcommercial and commercial applications. They can easily beinstalled on a roof curb, slab, roof jack or units are self-contained and assembled on rigid fullperimeter base rails with fork lift slots on three sides and holesfor overhead rigging. Every unit is completely piped, wired,charged and tested at the factory to provide for a quick andeasy field units are available in cooling only, and cooling with gas heaters are available as field-installed cabinet is constructed of galvanized steel, painted with longlasting, durable, and aesthetically pleasing power paint. Paintfinish meets 750 hour salt spray tests per ASTM-B117 models include a 5-year limited warranty on scrollcompressors and electric heating elements, a 10-year limitedwarranty on gas-fired heat exchangers and a 1-year limitedwarranty on all replacement FOOTPRINT/COMMON CABINET - All modelsizes and configurations share a common cabinet and acommon roof curb.

2 The installer has the flexibility of setting onecurb and placing the proper tonnage unit on that curb after theinternal load has been determined. He can even decidebetween gas or electric heat after the curb has been EFFICIENCY - All units have a high cooling efficiency,and gas / electric models have a minimum AFUE of 80%. Allefficiencies exceed legislated minimum levels and provide lowoperating AIRFLOW DESIGN - Both the side and bottomduct openings are covered when they leave the factory. If a sidesupply / side return is desired, you simply remove the two sideduct covers from the outside of the unit and discard them. If abottom supply / bottom return is desired, you simply remove thetwo knockout panels from the base of the unit and discard panel cutting or swapping is required! Convertible airflowdesign allows maximum field flexibility and minimum may be used on either bottom and side ductapplications with no modifications OPTIONS - Economizers can beinstalled at the factory.

3 The economizers are shipped installedand wired. Only the rain hood needs to be field assembled andinstalled. Field labor dollars can be saved by having thecomponents arrive already belt drive blowers are available on all models fromthe factory for complete airflow ACCESSORIES - Accessories weredesigned for quick and easy installation. The motorized damperand economizers simply slide in, and electrical connections aremade by modular plugs. Electric heaters mount easily, andknockouts are provided in the internal partitions to connect theelements to the control box SINGLE point motorized air damper includes a slid-in/plug-in damperassembly with a rainhood and filters. The outdoor air dampersopen when the indoor fan motor is energized. The damper iscapable of providing 0% through 100% of outdoor return manual outdoor damper provides 0% through 35% or 0%through 100% of return air opening (field adjustable).

4 Designedfor duct mounted side or bottom supply/return rain hood assembly and 14" high roof curb is shipped knocked down. An insulateddeck is not required because the bottom of the unit is ambient controls are available to provide stable unitoperation at outdoor temperatures down to 0 , high altitude and low NOx kits are also available tocover all gas heating RANGE OF INDOOR AIRFLOWS - All 3, 4 and 5-tonmodels operate over a wide range of design conditions with (500) SINGLE PACKAGEAIR-COOLEDAIR CONDITIONERSD4CE 036, 048, 060 & D2CE 072D7CG 036, 048, 060 & D2CG 0723, 4 AND 5 NOMINAL TONS (10 SEER)AND 6 NOMINAL TONS (9 EER)SUNLINE 2000 Cont MODELSHOWN 3-speed direct-drive fan motor. The 6-ton unit has a singlespeed direct-drive fan motor. Belt-drive blowers are alsoavailable on all 3, 4, 5 and 6-ton PERIMETER BASE RAILS - The permanently attachedbase rails provide a solid foundation for the entire unit andprotect the unit during shipment.

5 The rails provide fork liftaccess from 3 sides, and rigging holes are also provided sothat an overhead crane can be used to place the units on a PROTECTION - Internal overload protection arestandard on all scroll compressors. Every unit has a liquid linefilter-drier, high and low pressure/lose at charge switches and asuction line freezestat to protect all system components. All unitswill provide cooling at ambient temperatures down to 45 CONNECTIONS MADE EASY - Gas and electricutility knockouts are provided in the unit base as well as theside of the unit . A clearly identified location is provided to mounta field supplied electrical disconnect switch. Utility connectionscan be made quickly and with a minimum amount of field CONTROL CIRCUIT - A low voltage printed circuitboard contains a scroll compressor lockout indicator light anda low voltage terminal strip. An additional set of pin connectorsis also provided to simplify the field interface of externalcontrols.

6 Mate-n-lock plug connectors are used where line andlow voltage wires pass thru internal bulkheads. This allows foreasier troubleshooting and component replacement. Theelectrical control box is not located in the scroll compressorcompartment so the access cover can be removed fortroubleshooting without affecting the normal system operatingpressures. All wiring internal to the unit is color/number FILTERS - Units are shipped with 1" disposable filters. Theunit filter racks can accommodate 1" or 2" filters without OF CONTENTSFEATURES - CONT TUBE / ALUMINUM FINCONDENSER COIL20 GAUGE ALUMINIZED STEELTUBULAR HEAT EXCHANGERDIRECT DRIVEBLOWER MOTOR(Belt Drive Optionalso available onsome models)LOW VOLTAGE RELAY BOARDAND TERMINAL STRIPOUTDOOR AIR OPENINGFOR SLIDE-IN/PLUG ININTERNAL ECONOMIZER(ACCESSORY)ELECTRICAL DISCONNECTMOUNTING LOCATION(Field Installed)ECONOMIZER HOODSIDE RETURN AIRDUCT OPENING(Return Air & Supply AirSide by Side)BOTTOM RETURN AIRDUCT OPENING(Return Air & Supply AirSide by Side)3/4" PVC FEMALECONDENSATE DRAINKNOCKOUTS FOR SIDEPOWER AND CONTROLENTRYKNOCKOUT FOR BOTTOMGAS SUPPLY ENTRYKNOCKOUT FOR BOTTOMPOWER ENTRYKNOCKOUT FOR SIDEGAS SUPPLY ENTRYHIGH EFFICIENCYSCROLL COMPRESSORSBASE RAILSWITH FORKLIFT SLOTSAND LIFTING HOLESPOWER VENTER MOTORELECTRIC HEAT ACCESSORYLOCATION (Elec/Elec Units)TERMINAL BLOCK(For SINGLE Point PowerSupply on Elec/Elec Units)MODEL DCG(Gas Heating)

7 Static Resistances ..11 Motor and Drive Data ..11 Electrical Data - Basic Units ..11 Elec. Htg. 3 & 4 Ton w/Direct-Drive ..12 Elec. Htg. 5 & 6 w/Direct-Drive ..13 Elec. Htg. 3 & 4 w/Belt-Drive ..14 Elec. Htg. 5 & 6 w/Belt-Drive ..15 Field Wiring ..16 unit Dimensions .. 17 & 18 Roof Curb Dimensions ..19 Component Weights and Center of Applications ..20 Mechanical Specifications ..21 Description .. 1 Features .. 1 Ratings .. 3 Sound Power Ratings for Supply Air Blower .. 3 Physical 3 Cooling Capacities - 3 Ton .. 4 Cooling Capacities - 4 Ton .. 5 Cooling Capacities - 5 Ton .. 6 Cooling Capacities - 6 Ton .. 7 Blower Performance - 3 & 4 Ton w/Belt-Drive .. 8 Blower Performance - 5 & 6 Ton w/Belt-Drive .. 9 Blower Performance - 3 - 6 Ton w/Direct-Drive .. 10 Option and Accessories .. 10 SUNLINE 2000 Products GroupMODELARI RATINGS 1 GAS HEAT CAPACITYSTANDARDCFMCOOLING CAPACITY80 / 67-95 FSOUNDRATING2(dbels)INPUT(MBH)OUTPUT(MBH )AFUE(%) (%) ( F)GASLINE SIZE(in.)

8 OD) 21 21 21 21 in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. 2 Rated in accordance with ARI Standard 270. 3 Heaters are available as accessories - all with singlepoint power supply. 4 Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340 = Seasonal Energy Efficiency Ratio - the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same = Energy Efficiency Ratio - the cooling capacity in Btu s per hour (Btuh) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUH/watt).AFUE = Annual Fuel Utilization Efficiency - determined in accordance with DOE test = Steady State Efficiency. (Percent Output).RATINGSMODELARI RATINGS1 NOMINALELECTRIC HEAT CAPACITY3(KW)STANDARDCFMCOOLING CAPACITY80 / 67-95 FSOUNDRATING2(dbels) , 7, 10,15 & 207, 10,15 & 2010,15 & , 7, 10,15 & 207, 10,15 & 2010,15 & , 7, 10,15, 20 & 307, 10, 1520 & 3010, 15,20 & , 7, 10,15, 20 & 307, 10, 15,20 & 3010, 15,20 & RATINGS - Cooling / Gas HeatingCAPACITY RATINGS - Cooling / Electric Heating= Not ARI DATA - BASIC UNITSMODELEVAPORATORBLOWEREVAPORATORCOIL COMPRESSORTYPECONDENSERFA NCONDENSERCOILAIRFILTERS(SEE NOTE)CHARGECENTRIFUGAL(Dia.

9 X Wd. in.)FAN MOTOR HP(DIRECT-DRIVE)FAN MOTOR HP(BELT-DRIVE)ROWS DEEPFINS PER INCHFACE AREA(Sq. Ft.)HERMETICALLYSEALEDPROPELLERDIA. (in.)FAN MOTOR HPNOM. CFM TOTALROWS DEEPFINS PER INCHFACE AREA(Sq. Ft.)QUANTITYPER unit (15" X 20" X 1")QUANTITYPER unit (14" X 25" X 1")TOTAL FACEAREA (sq. ft.)REFRIGERANTR-22 ( )03612 x 101 211 43, x 103 411 43, x 10111 43, x 11111 43, : Filter racks are adapted for 1" or 2" thick POWER RATINGS FOR SUPPLY AIR BLOWERMODELCFMESPBLOWERSOUND POWER (dB 10-12 watts)OCTAVE BAND CENTERLINE FREQUENCY (Hz)SWLdB (A)dB (A)@10 ft.*IWGSPEEDKW631252505001,0002,0004,000 8,0000361, , , , * At a distance of 10 the : These values have been derived using a model of sound propagation, measuring the indoor ambient sound levels ten feet from the source. The dBA values provided are for reference only. Calculation of dBA values cover matters of system design and application. This constitutes an exception to any specification or guarantee requiring a dBA value or sound data in any other form than sound power level Products Group3 COOLING CAPACITIES - 3 TON (DCE / DCG036)Air OnEvaporatorCoilTemperature of Air on Condenser Coil105 F115 FTo t a Capacity1, MBHTo t a Capacity1, MBHCFMWB FEntering Dry Bulb, FEntering Dry Bulb, These capacities are gross ratings.

10 For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is KW. Refer to the Blower Performance Table for the KW of the supply air blower SENSIBLE CAPACITYAir OnEvaporatorCoilTemperature of Air on Condenser Coil85 F95 FTo t a Capacity1, MBHTo t a Capacity1, MBHCFMWB FEntering Dry Bulb, FEntering Dry Bulb, Products GroupAir OnEvaporatorCoilTemperature of Air on Condenser Coil105 F115 FTo t a Capacity1, MBHTo t a Capacity1, MBHCFMWB FEntering Dry Bulb, FEntering Dry Bulb, These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the These ratings include the compressor and the condenser fan motors but not the supply air blower motor.