Example: tourism industry

Site Plan Review Checklist - BWSC

site plan Review CHECKLISTB oston water and Sewer CommissionEngineering Customer ServiceWard/Parcel:Engineer-of-Record,Ti tle Company Name BWSC plan Examiner/DateItems DESCRIPTION OF site plan Narrative (provide a synopsis/Overview of all Project Utility related information) Address (Street Name & Number) & Parcel Information (Call out subdivisions and delineate lot lines on site plans) & Meter 's Name & Contact Landlord Number if of Street Numbering (Parcel Information included) "x5" Box (label as follows "FOR BWSC USE ONLY") Schedule (List all Applicable GSA items only)A10.

SITE PLAN REVIEW CHECKLIST Boston Water and Sewer Commission Engineering Customer Service Items DESCRIPTION OF SITE PLAN REQUIREMENTS COMMENTS/NOTES

Tags:

  Review, Checklist, Site, Water, Plan, Site plan review checklist

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Site Plan Review Checklist - BWSC

1 site plan Review CHECKLISTB oston water and Sewer CommissionEngineering Customer ServiceWard/Parcel:Engineer-of-Record,Ti tle Company Name BWSC plan Examiner/DateItems DESCRIPTION OF site plan Narrative (provide a synopsis/Overview of all Project Utility related information) Address (Street Name & Number) & Parcel Information (Call out subdivisions and delineate lot lines on site plans) & Meter 's Name & Contact Landlord Number if of Street Numbering (Parcel Information included) "x5" Box (label as follows "FOR BWSC USE ONLY") Schedule (List all Applicable GSA items only)A10.

2 Professional Engineer ( ) & Professional Land Surveyor (PLS) StampsA11. Limits of Public Way Excavation (L ft x W ft)A12. Rough Construction Sign-off Document [Prerequisite for filing a GSA with BWSC. Rough Const. sign-off provided by (ISD)]A13. Stationing (Station all new service connections. Note Sta 0+00 shall begin at property line of nearest intersection)A14. Utility Information [call out all utility in roadway: water , sewer, gas, phone, elec, steam, cable, ohw, ]A15. Elevations in Boston City Base (BCB): [NGVD Datum + or MTA-CA/T Datum + 100]A16. As-built plan [All as-built plans must be certified by the Engineer-of-record]A17 ACAD File (2006 or Lower)B18.

3 water - Main (Specify main size, material & history. Note: Per diem inspection fees of $ per day will apply)B19. water - Domestic water Service (Size, material type and connection detail) B20. water - Fire Protection Line (Specify size, mat'l, backflow device size, mfg and location)B21. water - Back-Flow Preventer (Specify type, mfg and size of device. Note: Application to be accompanied by sketch) B22. water - Hydrants (Indicate public or private. Provide details for new installations and/or relocations)B23. water - water Meter [Specify size & location (inside/outside), MTU. Note: Strainer must be installed upstream of the meter]B24. water - water Meter Sizing Calcs [Based on Fixture Unit (FU) count, demand factors from plumbing codes & Hunters Curve ]B25.

4 water - Cut & Cap(s) (Show Location , Specify pipe size, and station accordingly. Show all existing cut & caps)B26 water - Mechanical Fittings & Appurtenances (Call out off-sets, Bends, tapping sleeves, valves, three-way tee, etc)C27. Sewer - Main(s) (provide 20 - scale plan & profile of proposed sewer main)C28. Sewer - Service(s) - [2% min. slope (1/4" per foot) - also specify size, est. sewerage flow, material type, stationing, inverts]C29. Sewer - Grease Trap(s) - [Where Applicable, grease trap sizing calculations must accompany the site plan submittal]C30. Sewer - Oil/ water Separators (If Applicable)C31. Sewer - Cut & Caps (Show location , specify pipe size, and station accordingly.)

5 Show all existing cut and cap)C32. Sewer - Invert Elevation @ Bldg & Main (Boston City Base)C33. Sewer - Back water Valve (BWV) (Call out location & standard Detail)C34. Sewer - Connection Details (Call out Strap-on saddle or chimney-see BWSC standard details, Wye Branch @ main)Note: This check-list must be completed and submitted with each new site plan application. All applicant shall provide a copy of all supporting documentation and BWSC utility research information must accompany each site plan submittal. Please select all applicable items by indicating "Yes" or "No" using a check ( ) mark. Applicants may provide any additional explanatory remarks in the "Comments" section.

6 Additonal comments may be provided using a separate sheetBWSC site plan No.:Project Address District (NeighborhoodProject Name/Description:Date plan first recorded Contact Number Acct No.:Section A: General site InformationCheck "Yes" or "No" if ApplicableSection C: Sewer (Mains & Services)Section B: water (Mains & Services) - Fire and/or DomesticPage 1 of 2 BWSC site plan Review Checklist (Rev 2009).xlsLast rev: 02/20/2009 site plan Review CHECKLISTB oston water and Sewer CommissionEngineering Customer ServiceItems DESCRIPTION OF site plan REQUIREMENTSCOMMENTS/NOTESC heck "Yes" or "No" if ApplicableC35.)

7 Sewer - Clean-Out(CO) Location & DetailC36. Sewer - Dye Test Sign-off/Notation (dye test required for each connection to main)C37. Sewer - 4:1 Infiltration & Inflow Reduction Compliance (Based on PNF requirements. Contact Planning Dept if Applicable)Section D: Drain (Mains & Services)D38. Drain - Main(s): [provide 20 scale plan & profile, identify whether public or private]D39. Drain - Service(s): [1% min. slope (1/8" per foot) - also specify size, mat'l type, inverts at building and main, stationing]D40 Drain - Particle Separator/Stormceptor Units (for areas greater than 7,500 sq ft- Provide Rim & Invert elev)D41 Drain - Catch Basins with Oil Trap [for external paved areas less than 7,500 sq ft.]

8 Rim & Invert(s) Elevation required]D42 Drain - Fish Plates ("DO NOT DUMP") Plaque(s) - call out quantity(ies) and show location of all plaquesD43 Drain - Infiltration Systems & Details (specify type & storage Capacity, rims and invert elevations)D44 Drain - Cut & Caps (Show location , specify pipe size, and station accordingly. Show all existing cut & cap)D45 Drain - Dye Test Sign-off/Notation (Dye test required for each connection to the main)D46 Drain - Pre/Post Drainage Calculations [Increase in net impervious cover]D47 Drain - Calculations for Article 32 Compliance: Storage & Recharge (provide supporting calculations and doc)D48 Permit - BWSC General Service Application (GSAs)-Old/NewD49 Permit - Sewer Ext Permit (Sewerage flows greater than 50,000 gpd)D50 Permit - Copy of MWRA Sewer Use Discharge PermitD51 Permit - Copy of MWRA Direct Connect permit [for Direct Connections Only]D52 Permit - Copy of MWRA 8(m) Permit (for crossings and work within 10-ft of existing sewer)D53 Approvals - PIC Coordination Required (provide copy(ies) of all PIC plan submittals)D54 Approvals - One-Time Certification [Sewerage flows >=15,000 or <=50,000 gpd or Sewer Extension less than l,000 ft]D55 Approvals - Copy of DCR Approval(s)

9 (if Applicable Only)D56 Easement - Existing/New Easement Request Document(s) (Note: forms are available on line at )D57 Easement - Existing/New License Request Document(s)D58 Demo - Demolition plan ( Delineate buildings, utility mains and services to be cut and capped, abandoned and/or demolished )D59 Demo - Dewatering plan (If Applicable)F60. Special Condition - As-built Conditions letter (prepared by BWSC and must be to be signed by property owner/Rep)F61. Special Condition - Article 32 Compliance Letter (prepared and issued to property owner and zoning board from BWSC )F62. Approvals - Conservation Commission Approval (If Applicable)F63 Approvals - Historical Society Approval (If Applicable)F64.

10 Documentation - Letter of Agreement & Understanding [LOAU] for 4:1 I & I Reduction Fee CalculationsF65. Documentation - Condo Agreement Letter and/or Notation (Required for Condo Developments)F66. Documentation - Access & Utility Easement plan (Required when filing new easements with Land Court)G67 Index Card(s) - Distance & Connection Cards ( water )G68 Index Card(s) - Distance & Connection Cards (Sewer & drain)G69 Maps - 100 Scale GIS Map ( water )G70 Maps - 100 Scale GIS Map (Sewer & Drain)G71 Maps - Old Sewer SectionsG72 Maps - Old Bromley Map ( water only)G73 Plans - Record Plans ( Review old Inspection & Survey Books)G74 Plans - CIP Plans (Request Plans & Association Information, as-built plans & Design drawings)G75 Plans - site Plans (Pending Review or approved)G76 Street Listing - Guaranteed Street Listing (Boston Public Works Dept)