Example: air traffic controller

Smith Meter Valves 200 Series Hydraulic Control Valves

Application BulletinIssue/Rev. (4/07) Bulletin AB03004 Smith MeterTM Valves200 Series Hydraulic Control ValvesThe Most Trusted Name In MeasurementTable of ContentsElectrical Block ..Page 3 Mechanical Block ..Page 3 Flow-Limiting ..Page 3 Pressure-Relief ..Page 4 Pressure-Sustaining ..Page 4 Differential Back-Pressure Sustaining ..Page 4 Check with 5 Two-Stage Electro- Hydraulic Set-Stop with Flow-Limiting ..Page 5 Digital Electro- Hydraulic Set-Stop ..Page 5 Digital Electro-Pneumatic Set-Stop ..Page 6 Pressure-Limiting ..Page 6 Options ..Page 7 Valve Function Combinations ..Page 8 Smith MeterTM Control Valve Function Intermix ..Page 8 Other Configurations ..Page 9 Materials of Construction ..Page 10 Dimensions ..Page 11 Issue/Rev. (4/07)Page 2 AB03004 Smith MeterTM 200 Series Control Valves feature hydraulically-operated, diaphragm-actuated globe Valves .

Application Bulletin Issue/Rev. 0.2 (4/07) Bulletin AB03004 Smith MeterTM Valves 200 Series Hydraulic Control Valves The Most Trusted Name In Measurement

Tags:

  Series, Control, Hydraulic, Valves, Valves 200 series hydraulic control valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Smith Meter Valves 200 Series Hydraulic Control Valves

1 Application BulletinIssue/Rev. (4/07) Bulletin AB03004 Smith MeterTM Valves200 Series Hydraulic Control ValvesThe Most Trusted Name In MeasurementTable of ContentsElectrical Block ..Page 3 Mechanical Block ..Page 3 Flow-Limiting ..Page 3 Pressure-Relief ..Page 4 Pressure-Sustaining ..Page 4 Differential Back-Pressure Sustaining ..Page 4 Check with 5 Two-Stage Electro- Hydraulic Set-Stop with Flow-Limiting ..Page 5 Digital Electro- Hydraulic Set-Stop ..Page 5 Digital Electro-Pneumatic Set-Stop ..Page 6 Pressure-Limiting ..Page 6 Options ..Page 7 Valve Function Combinations ..Page 8 Smith MeterTM Control Valve Function Intermix ..Page 8 Other Configurations ..Page 9 Materials of Construction ..Page 10 Dimensions ..Page 11 Issue/Rev. (4/07)Page 2 AB03004 Smith MeterTM 200 Series Control Valves feature hydraulically-operated, diaphragm-actuated globe Valves .

2 Liquid Control is accomplished by using line pressure or an external pressure source for actuation of the Compact Design and Mechanical Simplicity - Lower maintenance costs. In-Line Serviceability - Reduced maintenance time. Drip-Tight Closure - Positive valve shut-off. No External Packing Gland - Reduced chance of leakage to Application Notes Suitable for horizontal or vertical applications. Maximum ViscosityAll Valves will operate satisfactorily up to 200 SSU (45 mPa s)1 viscosity. For operation on higher viscosity products, consult the factory. Elastomer/Valve Temperature Limits2 Buna-N Elastomers: -20 F to 200 F (-28 C to 93 C). Low Swell (LS) Buna-N Elastomers: -20 F to 200 F (-28 C to 93 C).Viton Elastomers: -20 F to 350 F (-28 C to 177 C). Maximum Working PressureDiaphragm Type Bare Valves : Class 150 ASME Cast Steel: 285 psig @ 100 F maximum working pressure (1,965 kPa @ 38 C).

3 Class 300 ASME Cast Steel: 300 psig @ 100 F maximum working pressure (2,068 kPa @ 38 C). Direction of FlowFor 200 Series Valve Packages: For Bare Valves : Model 200 is fail-closed/flow-over-the-seat. Model 202 is fail-closed/flow-over-the-seat. Model 201 is fail-open/flow-under-the-seat. Model 203 is fail-open/flow-under-the-seat. Flow Rate Size 2" 3" 4" 6" 130 420 600 1,000 Nominal Flow - USGPM (L/min) (492) (1,600) (2,250) (3,750) 1 1mPa s = Temperature Limits are based on the following: (a) minimum temperature rating of the housing, (b) effective temperature of one of the seals, (c) min/max. temperature limit of typical (4/07)AB03004 Page 3 Electrical BlockUsed as a fail-closed system permissive for remote opening or closing by an electrical switch, manually- or auto-matically-actuated.

4 Typically used with the Smith MeterTM Model DE-1 Dual Electric Air Release Head mounted on a system air BlockTypically used in off-loading flow measurement systems in conjunction with an air eliminator tank having a special Petro-gard-type air release head. It can be used in a fail-closed or fail-open primarily in systems with parallel Meter runs to protect the meters against excessive flow rate when less than the maximum number of Meter runs are operating. FlowOrificePlateStrainerLow PressureSense LineSensitivityAdjustmentRate-of-FlowPil ot (40A)High PressureSense Line FlowStrainerBack-PressurePilot (23PG)SensitivityAdjustmentInternalOrifi cePetro-gard TypeRB HeadVentCustomerSupplied FlowStrainerSensitivity AdjustmentNormally-ClosedSolenoid (30A)TruckRailBargeHorizontal Air Eliminator Tankw/Petro-gard RB HeadStrainerPD MeterVentTo StorageMechanical Block ValveModel 200-30 AModel 200-40 AModel 200-23 PGPD MeterFlow-LimitingValveStrainerPumpTruck RailBargeDE-1 Dual Electric Air Release HeadVentAirEliminatorTankPD MeterElectrical Block ValveTo StorageIssue/Rev.

5 (4/07)Page 4 AB03004 Pressure-ReliefNormally a fail-open valve, installed in a pump bypass line to Control pump discharge a predetermined minimum back-pressure when installed downstream of the pump. Commonly used to provide minimum back-pressure for turbine Meter Back-Pressure SustainingUsed in LPG metering applications to maintain system pressure above the product vapor pressure in order to pre-vent 201-60 AModel 200-60 AModel 200-63A FlowStrainerSense LineSensitivityAdjustmentBack-Pressure Pilot (60A) FlowStrainerSense LineSensitivityAdjustmentBack-PressurePi lot (60A) FlowStrainerSense LineSensitivityAdjustmentDifferential Back-Pressure Pilot(63A)Customer-InstalledRemote Senseof Vapor PressurePressure-Relief ValvePumpStorageTankDownstream SectionUpstream SectionPumpStrainerTurbineMeterPressure- Sustaining ValvePumpCondensing Tankw/ Vapor BombPD orTurbine MeterStrainerDifferential Back-Pressure ValveIssue/Rev.

6 (4/07)AB03004 Page 5 Two-Stage Electro- Hydraulic Set-Stop with Flow-LimitingA set-stop valve commonly used for low viscosity petroleum loading rack applications. Provides electrically-actuated, two-stage closure when operating in conjunction with positive displacement meters equipped with electro-mechanical preset counters. Meter protection against overspeed is provided by a flow-limiting pilot sensing pressure drop across a valve inlet-mounted orifice with Thermal ReliefThe check features prevents reverse flow should valve outlet pressure exceed inlet pressure. The thermal relief feature automatically provides relief upstream for downstream thermal 202CH-07 AModel 296-40A FlowThermal ReliefPilot (07A) FlowOrificePlateStrainerSense LinesSensitivityPositionSwitchNormally-O penSolenoid (30B)Normally-ClosedSolenoid (30A)Rate-of-FlowControl Pilot(40A)PumpStrainerPD MeterCheck Valve w/ Thermal ReliefMechanicalSet Stop ValvePD orTurbineMeterStrainerSet-Stopw/Flow-Lim itingFrom StoragePumpDigital Electro- Hydraulic Set-StopUsed in conjunction with a Smith SS1 Controller, AccuLoad, or MiniLoad to provide electrically-actuated, multi-stage closure and rate-of-flow limiting in low viscosity loading rack applications.

7 Works equally well with positive displace-ment or turbine meters. FlowStrainerOpeningSpeedControlNormally- ClosedSolenoid (30A)Normally-OpenSolenoid (30B)ClosingSpeedControlModel 210 ACCULOAD IILoad PrinterAccuLoad PPS orPEXPT ransmitterPD orTurbineMeterDigital HydraulicSet-Stop ValveStrainerPumpFrom StorageIssue/Rev. (4/07)Page 6 AB03004 Pressure-LimitingUsed in nondead-end service where it is necessary to limit downstream pressure (during flow) to protect lower pres-sure rated equipment. This valve was not designed to be a systems main pressure 200-64 ADigital Electro-Pneumatic Set-StopUsed in conjunction with a Smith MeterTM SS1 Controller, AccuLoad, or MiniLoad to provide electrically-actuated, multi-stage closure and rate-of-flow Control in high viscosity batching applications.

8 External air pressure is utilized to actuate the opening and closing of the SpeedControlNormally-OpenSolenoid (30B)Normally-ClosedSolenoid (30A)OpeningSpeedControl Customer-SuppliedPneumatic PressurePneumaticActuatorWafer SphereValveVentModel 215 From StoragePD MeterStrainerSS1 ControllerDigital PneumaticSet-Stop ValvePumpCustomer-SuppliedPneumatic Pressure FlowStrainerSensitivityPressure ReducingPilot (64A) Sense LineIssue/Rev. (4/07)AB03004 Page 7 OptionsSmith 200 Series Control Valves are available with a variety of optional accessories which are used to enhance overall valve performance. Options include opening and closing speed controls, mechanical position indicators, position switches, and, where applicable, low-flow start timers and pre-wired junction 03A Opening/Closing Speed ControlsModel 04A Mechanical Position Indicator and SwitchPre-Wired Junction Box on Model 296-40A-15AX ValveModel 15AX Low-Flow Start TimerBall ValvesNote: These products have been designed for petroleum applications, where corrosion/erosion is normally minimum.

9 The design of the pressure containing housings have adequate material allowance for typical petroleum applications. Consult the factory for other applications or for the actual material (4/07)Page 8 AB03004 Valve Function CombinationsModel 200-40A-30A Combination Flow-Limiting and Electrical BlockModel 296-80B/07A-40A Set-Stop with Flow-Limiting in Combination with Check and Thermal-Relief FlowOrificePlateStrainerSense LinesSensitivityRate-of-FlowControl Pilot(40A)Normally-ClosedSolenoid (30A) FlowStrainerPositionSwitchNormally-OpenS olenoid (30B)Normally-ClosedSolenoid (30A)ThermalRelief (07A) Check Pilot(10B)Check Pilot(10B) OrificePlateRate-of-FlowControl Pilot (40A)Sense LinesSensitivity Smith MeterTM Control Valve Function IntermixBasic TypeFunctionElectrical BlockMechanical BlockFlow-LimitingPressure-LimitingPress ure-ReliefBack Pressure SustainingDifferential Back-Pressure SustainingCheck with Thermal-ReliefTwo-Stage Set-Stop with Flow LimitingDigital Hydraulic Set-Stop, 210 Digital Pneumatic Set-Stop, 215 Opening/Closing Speed OptionLow-Flow Start OptionPosition IndicatorPosition SwitchJunction BoxElectrical BlockACBBCBBDDDDB,ADBBBM echanical BlockCABBCBCDDDDA,BDBBCFlow-LimitingBBAB BBBBDDDB,ADBBCP ressure-LimitingBBBADBCBDDDB,ADBBCP ressure-ReliefBCCCADCBDDDB,ADBBCBack-Pre ssure SustainingBBBBDACBDDDB,ADBBCD ifferential Back-Pressure SustainingBBBBCCABDDDB,ADBBCC heck with Thermal-RefliefDDBBBBBADDDB.

10 BDBBCTwo-Stage Set-Stop with Flow LimitingACABBBBBADDB,ABAABD igital Hydraulic Set-Stop, 210 ABABCBBBDADA,AABBAD igital Pneumatic Set-Stop, 215 ABADDDDDDDAA,AAABAA - Standard function C - AtypicalB - Typical D - Not possibleMost Smith 200 Series Valves are capable of performing multiple con-trol functions. A typical single valve arrange-m e n t , fo r ex a m p l e, combines flow-limiting Control with electrical block. Another common arrangement is that of a set-stop valve with flow-limiting in combination with check and available options and possible Control function combinations are tabulated (4/07)AB03004 Page 9 Other ConfigurationsModel 200-40A-23PG-07A Combination Flow-Limiting and Back Pressure Sustaining (Petro-gard) with Thermal-ReliefModel 296-60A-50B-42A Combination Two-Stage Set-Stop with Flow-Limiting, Back-Pressure Sustaining, and Pressure-LimitingModel 200-185A-60A-30A Combination Back-Pressure Sustaining and Electrical Block with Opening Speed ControlModel 210-23BP Digital Hydraulic Set-Stop with Back-Pressure Sustaining ControlModel 200-60A-40A-30A Combination Back-Pressure Sustaining, Flow-Limiting, and Electrical BlockModel 210-80B/07A-23PG-04B Combination Digital Hydraulic Set-Stop and Back-Pressure Sustaining (Petro-gard) with Check, Thermal-Relief, and Position Switch FlowOrificePlateStrainerSense LinesPetro-gardBack-PressurePilot (23PG)SensitivityThermal Relief(07A)Rate-of-FlowControl Pilot(40A)