Example: bachelor of science

Speed Controller with Pilot Check Valve with One-touch ...

Speed Controller with Pilot Check Valve with One-touch Fitting ASP Series RoHS. AS-F. Model TMH. Pilot Check Valve and Speed con- troller are combined. ASD. Applicable tubing Realizes momentary intermediate Model Port size Pilot port Metric size Inch size stoppage of a cylinder and able to 6 8 10 12 1/4" 5/16" 3/8" 1/2" AS. adjust Speed control of it. ASP330F-01 R 1/8 M5 x ASP430F-02 R 1/4 Rc 1/8 AS-FE. ASP530F-03 R 3/8 Rc 1/8. ASP630F-04 R 1/2 Rc 1/4 KE. ASP430F-F02 R 1/4 G 1/8. ASP530F-F03 R 3/8 G 1/8 AS-FG. ASP630F-F04 R 1/2 G 1/4. ASP330F-N01 NPT 1/8 10-32 UNF AS-FP. ASP430F-N02 NPT 1/4 NPT 1/8. ASP530F-N03 NPT 3/8 NPT 1/8 AS-FM. ASP630F-N04 NPT 1/2 NPT 1/4. Note) Brass parts are all electroless nickel plated. AS-D. Work AS-T. piece Specifications ASP. Example of drop prevention circuit Fluid Air ASN. Tubing mount direction is 360 free.

D3 ø D1 ø D2 L5 T2 T1 L4 L2 Applicable tubing O.D. ød L3 M L1 A1 ∗ A2 ∗ ø D3 ø D1 ø D2 T2 T1 L4 Applicable tubing O.D. ød H1 (Hexagon width across flats) H2 (Hexagon width across flats) H1 (Hexagon width across flats) H2 (Hexagon width across flats) ASP Series Speed Controller with Pilot Check Valve with One-touch Fitting Dimensions ...

Tags:

  Valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Speed Controller with Pilot Check Valve with One-touch ...

1 Speed Controller with Pilot Check Valve with One-touch Fitting ASP Series RoHS. AS-F. Model TMH. Pilot Check Valve and Speed con- troller are combined. ASD. Applicable tubing Realizes momentary intermediate Model Port size Pilot port Metric size Inch size stoppage of a cylinder and able to 6 8 10 12 1/4" 5/16" 3/8" 1/2" AS. adjust Speed control of it. ASP330F-01 R 1/8 M5 x ASP430F-02 R 1/4 Rc 1/8 AS-FE. ASP530F-03 R 3/8 Rc 1/8. ASP630F-04 R 1/2 Rc 1/4 KE. ASP430F-F02 R 1/4 G 1/8. ASP530F-F03 R 3/8 G 1/8 AS-FG. ASP630F-F04 R 1/2 G 1/4. ASP330F-N01 NPT 1/8 10-32 UNF AS-FP. ASP430F-N02 NPT 1/4 NPT 1/8. ASP530F-N03 NPT 3/8 NPT 1/8 AS-FM. ASP630F-N04 NPT 1/2 NPT 1/4. Note) Brass parts are all electroless nickel plated. AS-D. Work AS-T. piece Specifications ASP. Example of drop prevention circuit Fluid Air ASN. Tubing mount direction is 360 free.

2 Proof pressure MPa Electroless nickel plated is provided Max. operating pressure 1 MPa AQ. as standard. Min. operating pressure MPa Pilot Check Valve operating pressure More than 50% the operating pressure (Over MPa) ASV. Ambient and fluid temperature 5 to 60 C (No freezing). Applicable tubing material Nylon, Soft nylon, Polyurethane AK. Note) Use caution regarding the max. operating pressure when soft nylon or polyurethane tubing is used. (Refer to pages 464 and 465 for details.) VCHC. ASR. ASQ. Flow Rate and Sonic Conductance Model ASP330F ASP430F ASP530F ASP630F. Metric size 6, 8 6 8 8 10 10 12. Tubing 1/4" 1/4" 3/8". Inch size 5/16" 3/8" . Symbol 5/16" 5/16" 1/2". Flow rate Controlled 180 330 350 600 750 1100 1190. (L/min(ANR)). flow Free flow Sonic conductance dm3/(s bar). Controlled flow Critical pressure Made to Order ratio Free flow Note) Flow rate values are measured at MPa and 20 C.

3 Lubricant: Vaseline X12. 769 A. ASP Series How to Order ASP 3 3 0 F 01 06 S. Lock nut option Nil Hexagon lock nut J Round lock nut Made to Order Pilot Check Valve X12 Lubricant: Vaseline Ex.) ASP330F-01-06S-X12. Body size With seal 3 1/8 standard 4 1/4 standard Applicable tubing Note). 5 3/8 standard Metric size Inch size 6 1/2 standard 06 6 07 1/4". 08 8 09 5/16". 10 10 11 3/8". Universal 12 12 13 1/2". Note) For applicable tubing selection, refer to the Model on page 767. With One-touch fitting Port size Symbol Cylinder side Pilot port 01 R 1/8 M5 x 02 R 1/4 Rc 1/8. 03 R 3/8 Rc 1/8. 04 R 1/2 Rc 1/4. F02 R 1/4 G 1/8. F03 R 3/8 G 1/8. F04 R 1/2 G 1/4. N01 NPT 1/8 10-32 UNF. N02 NPT 1/4 NPT 1/8. N03 NPT 3/8 NPT 1/8. N04 NPT 1/2 NPT 1/4. Needle Valve / Note) The flow rate characteristics are Flow Rate Characteristics representative values.

4 ASP330F ASP430F. 200 400. Flow rate (L/min (ANR)). Flow rate (L/min (ANR)). Inlet pressure : MPa Inlet pressure : MPa 07,08,09 06. 300. 100 200. 100. 0 0. 5 10 5 10. Number of needle rotations Number of needle rotations ASP530F ASP630F. 1000 1500. Inlet pressure : MPa Inlet pressure : MPa Flow rate (L/min (ANR)). Flow rate (L/min (ANR)). 11,12,13. 10. 10,11 1000. 08,09. 500. 500. 0 0. 5 10 5 10. Number of needle rotations Number of needle rotations 770. Speed Controller with Pilot Check Valve with One-touch Fitting ASP Series Dimensions L2. L3 Applicable tubing d M. D. L1. 2. AS-F. T2 L4 TMH. H1. (Hexagon width across flats). H2. ASD. (Hexagon width across flats). AS. AS-FE. D3. A1 . L5. KE. D1. A2 . AS-FG. Metric Size T1 AS-FP. L4 (1). Model d T1 T2 H1 H2 D1 D2 D3 L1 L2 L3. Max. Min. L5 A1 (2) A2 (2) M. Weight (g). AS-FM. ASP330F-01-06S 6 14 32.

5 ASP330F-01-08S 8. R 1/8 M5 x 12 8. 35 AS-D. ASP430F-02-06S 6 18 65. R 1/4 1/8 17 12 15 ASP430F-02-08S 8 68 AS-T. ASP530F-03-08S 8 107. R 3/8 1/8 19 12 23 50 ASP530F-03-10S 10. 10. 110 ASP. ASP630F-04-10S 212. R 1/2 1/4 24 17 ASP630F-04-12S 12 66 215. Note 1) Reference dimensions ASN. Note 2) Reference dimensions of R thread after installation. Applicable tubing d L2. L3 AQ. M. ASV. AK. D. 2. L1. VCHC. ASR. T2 L4 ASQ. H1. (Hexagon width across flats). H2. (Hexagon width across flats). D3. A1 . L5. D1. A2 . T1. Inch Size L4 (1) Weight Model d T1 T2 H1 H2 D1 D2 D3 L1 L2 L3 L5 A1 (2) A2 (2) M. Max. Min. (g). ASP330F-N01-07S 1/4" 17. NPT 1/8 10-32 UNF 1/2" 8 35. ASP330F-N01-09S 5/16" ASP430F-N02-07S 1/4" 17. NPT 1/4 NPT 1/8 11/16" 1/2" 15 18 68. ASP430F-N02-09S 5/16" ASP530F-N03-09S 5/16" 107. NPT 3/8 NPT 1/8 19 1/2" 23 ASP530F-N03-11S 3/8" 116.

6 ASP630F-N04-11S 3/8" 220. NPT 1/2 NPT 1/4 15/16" 11/16" ASP630F-N04-13S 1/2" 230. Note 1) Reference dimensions Note 2) Reference dimensions of NPT thread after installation. 771. ASP Series Construction @4 w @0 !9 !8. !2 !0 !5 !6 !4 @5 !3. @3 q r t u i !7 !1 @1 y o e Component Parts Component Parts No. Description Material Note No. Description Material Note 1 Body A PBT 14 DY seal NBR. 2 Elbow body PBT 15 DY seal NBR. 3 Handle PBT 16 Spring Stainless steel 4 Pilot body Brass Electroless nickel plated 17 Spring Stainless steel 5 Body B Brass Electroless nickel plated 18 Cassette . 6 Needle Brass Electroless nickel plated 19 Seal NBR. 7 Needle guide Brass Electroless nickel plated 20 Spacer . 8 Guide Brass Electroless nickel plated 21 O-ring NBR. 9 Lock nut Steel (2) Zinc chromated (1) 22 O-ring NBR. 10 Piston Brass Electroless nickel plated 23 O-ring NBR.

7 11 Valve Stainless steel, NBR 24 O-ring NBR. 12 Cover Brass Electroless nickel plated 25 Ring Stainless steel 13 U seal HNBR. Note 1) The round lock nut is electroless nickel plated. Note 2) The round lock nut is made of brass. However, note that only the ASP330F and ASP430F use steel. 772. ASP Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 543 to 546 for Flow Control Equipment Precautions. Design/Selection Installation Warning Warning AS-F. 1. This product cannot be used for accurate and 1. When mounting, please firmly align the tool with precise intermediate stops of the actuator. the hexagon width across flats of the Pilot body. If TMH. Due to the compressibility of air as a fluid, the actuator will the hexagon width across flats is damaged as a continue to move until it reaches a position of pressure result of failure to properly align the tool, the Pilot ASD.

8 Balance, even though the Pilot Check Valve closes with an body will be deformed, and poor Pilot operation intermediate stop signal. may result. AS. 2. This product cannot be used to hold a stop position 2. Do not apply excessive force or shock to the cover for an extended period of time. ( Pilot port portion), fittings, or other parts of the AS-FE. Pilot Check valves and actuators are not guaranteed for zero product with tools. Also, do not apply any moment, air leakage. Therefore, it is sometimes not possible to hold a stop position for an extended period of time. In the event that twisting, pulling, or other external force when KE. holding for an extended time is necessary, a mechanical connecting a fitting to the cover ( Pilot port portion). means for holding should be devised. or after mounting. Doing so may result in damage AS-FG. 3.

9 Consider the release of residual pressure. or air leakage. Actuators may move suddenly due to residual pressure, which When connecting piping, use a tube of sufficient AS-FP. can be dangerous during maintenance procedures. length, in accordance with the recommended pip- 4. When used in a balance control circuit, there are ing conditions described in Fig. 1. When binding AS-FM. the piping together with a tying band, etc., be sure instances in which the Check Valve cannot release, even though the Pilot pressure is 50% of the operat- that external force is not being applied to the pip- AS-D. ing. (Refer to Fig. 2.). ing pressure. In these cases, the Pilot pressure should be the same as the operating pressure. AS-T. 5. For reference, SMC has conducted endurance tests in which ON, OFF operation of the Check Valve was ASP. Straight line performed at the maximum operating pressure, with a confirmed endurance of 10 million opera- Mounting ASN.

10 Pitch A. tions. Since the tests were performed under limited condi- Fig. 1 Recommended piping AQ. tions, use caution in evaluating the results. Unit: [mm]. Tubing size Mounting pitch A Straight line ASV. 6. The Check Valve has a construction, in which it is Nylon tubing Soft nylon tubing Polyurethane tubing length closed by the differential pressure generated when 2 13 or more 10 or more the inlet pressure (IN side) or outlet pressure (OUT , 1/8" 44 or more 35 or more 25 or more 16 or more AK. 4, 5/32" 56 or more 44 or more 26 or more 20 or more side) solenoid Valve is switched. Be aware that the Check Valve does not close completely and the 3/16" 67 or more 52 or more 38 or more 24 or more VCHC. 6 84 or more 66 or more 39 or more 30 or more outlet pressure (OUT side) may drop when the inlet 1/4" 89 or more 70 or more 57 or more 32 or more ASR.