Split System Cooling Product & Performance Data

Split SystemCooling Product & Performance DataPUB. NO. 22-1739-01-0402 (EN)XB102 TTB0030-060A2 5 TonsSS-PRC012-EN 2002 American Standard Inc. All Rights Reserved222-1739-01-0402 (EN)GeneralFeaturesSplit System Cooling Units ..The Evolution Continuestechnology and customer research todevelop the next generation of the Trane reputation for reliabilityand durability with the above mentionedmission and accomplishments and youcontinue to have systems that prove It s Hard to Stop a Trane . 2 TTB0 Split systems represent a productthat is not only an engineer s dream, it salso a customer s dream. The designteam s mission and accomplishment isenhanced Performance and efficiency,improved reliability and durability, andimproved installability and s experienced design team applied six sigma principles , the latest computer22-1739-01-0402 (EN)3 ContentsGeneral Features2 Features and Benefits4 Optional Equipment5 Low Outdoor Ambient Sta

Split System Cooling Product & Performance Data PUB. NO. 22-1739-01-0402 (EN) XB10 2TTB0030-060A 2½ – 5 Tons SS-PRC012-EN

Tags:

  Performance, Product, System, Data, Split, Cooling, Split system cooling product amp performance data

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Split System Cooling Product & Performance Data

1 Split SystemCooling Product & Performance DataPUB. NO. 22-1739-01-0402 (EN)XB102 TTB0030-060A2 5 TonsSS-PRC012-EN 2002 American Standard Inc. All Rights Reserved222-1739-01-0402 (EN)GeneralFeaturesSplit System Cooling Units ..The Evolution Continuestechnology and customer research todevelop the next generation of the Trane reputation for reliabilityand durability with the above mentionedmission and accomplishments and youcontinue to have systems that prove It s Hard to Stop a Trane . 2 TTB0 Split systems represent a productthat is not only an engineer s dream, it salso a customer s dream. The designteam s mission and accomplishment isenhanced Performance and efficiency,improved reliability and durability, andimproved installability and s experienced design team applied six sigma principles , the latest computer22-1739-01-0402 (EN)

2 3 ContentsGeneral Features2 Features and Benefits4 Optional Equipment5 Low Outdoor Ambient Standard Capacity Rating Conditions5 Selection Procedure6 Model Number Nomenclature6 General Data72 TTB0030A1000A72 TTB0036A1000A92 TTB0042A1000A112 TTB0048A1000A132 TTB0060A1000A15 Ratings with Auxiliary Devices17 Performance data Cooling182 TTB0030A1182 TTB0036A1192 TTB0042A1202 TTB0048A1212 TTB0060A122 Electrical Data23 Dimensions25 Mechanical Specification Options26422-1739-01-0402 (EN)Features andBenefits Climatuff compressor All aluminum Spine Fin coil DuraTuff base, fast complete drain,weather proof New cabinet with anthracite base andpolystate gray cabinet Quick-Sess cabinet, service accessand refrigerant connections with fullcoil protection Corrosion resistant finish and fasteners High/low pressure & temperatureprotection Liquid line filter-drier Easy single side service Multi-use liquid and suction line servicevalves Easy top & fan removal Full length control cover Sure Fast seams louver panelremoval HCFC-22 refrigerant 5-year limited warranty oncompressor, coil.

3 And 5 years onparts (Residential use) Extended warranties available design testing 100% line run test Low ambient Cooling to 55 F asshipped Low ambient to 40 F withEDC accessory AY28X079 Low ambient Cooling to 30 F withEDC accessory AY28X079 and TXV22-1739-01-0402 (EN)5 Features Standard Capacity Rating STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F. , 67 F. air entering indoor coil, 95 F. airentering outdoor Outdoor Ambient CoolingLow AmbientAsEvaporatorCoolingManufacturedDe frost ControlFCCV Accutron 55 F40 FThermal Expansion Valve (TXV)55 F30 FOptional EquipmentOPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [ ] indicates accessories included).

4 Indoor Thermostats Electronic TAYSTAT300C [ ]Electronic, 1 Htg. (Gas)/1 Clg. (Non Prog.).. TAYSTAT370 [ ]Electronic, 1 Htg. (Elec.)/ 1 Clg. (Non Prog.) TAYSTAT371[ ]Heating/ Cooling AY28X092 [ ] Cooling Only with Fan BAYSTAT304 [ ]Heating/ Cooling BAYSTAT305 [ ]Thermostat Locking BAY28X190 [ ]Outdoor Thermostats 46 F. to -10 F. (Adjustable).. TAYSTAT250B [ ]Evaporator Defrost AY28X079 [ ]Indoor Fan Delay Relay BAY24X045 [ ]Quick-Start Kit (2 TTB0030-060A).. BAYKSKT257 [ ]5 Minute Delay TAYASCT501A [ ]Outdoor Temperature Sensor .. (TAYSTAT300C).. TAYSENS100A [ ]Extreme Conditions BAYECMT001 [ ]Seacoast BAYSEAC001 [ ]1 Not used with programmable thermostats2 Specifically designed for electric heat applications (instant on fan)BRAZED TUBING REFRIGERANT LINE SETS (All Suction Lines are Insulated.)

5 3/4" ODM (90 bend, one end), 3/4" & 5/16" TAYREFLN2__* [ ]7/8" ODM (90 bend, one end), 7/8" & 3/8" TAYREFLN3__* [ ]1-1/8" ODM (90 bend, one end), 1-1/8" & 3/8" TAYREFLN4__* [ ]*Line lengths: 15, 20, 25, 30, 40 & 50 ft. Insert desired line length in catalog number at right for the complete : TAYREFLN220622-1739-01-0402 (EN)Refrigerant Type2 = R-224 = R-410 ATRANEP roduct TypeW = Split Heat PumpT = Split CoolingProduct FamilyZ = LEADERSHIP - 2 STAGEX = LEADERSHIPR = REPLACEMENT / RETAILB = BASICA = LIGHT COMMERCIALF amily SEER0 = 102 = 124 = 141 = 113 = 136 = 168 = 18 Unit PartsIdentifierMinor DesignModificationsSecondaryFunctionPowe r Supply1 = 200 - 230 / 1 / 60 or 208 - 230 / 1 / 603 = 200 - 230 / 3 / 604 = 460 / 3 / 60 Major Design ModificationsNominal Capacity in 000 s of BTU sSplit System Connections 1 - 6 Tons0 = Brazed1 2345 6 7891011121314152 TTB0 036A 1 000 AASelectionProcedureModel Number Nomenclature22-1739-01-0402

6 (EN)7 OUTDOOR UNIT 122 TTB0030A1000 ASOUND RATING (DECIBELS) 2981 POWER CONNS. V/PH/HZ 3200/230/1/60 MIN. BRCH. CIR. AMPACITY17BR. (AMPS)30 PROT. RTG. }MIN. (AMPS)30 COMPRESSORCLIMATUFF NO. USED - NO. SPEEDS1 - 1 VOLTS/PH/HZ200/230/1 AMPS 7 - - INSTALLEDSTART COMPONENTS 8 NOINSULATION/SOUND BLANKETNOCOMPRESSOR HEATNOOUTDOOR FAN TYPEPROPELLERDIA. (IN.) - NO. USED19 - 1 TYPE DRIVE - NO. SPEEDSDIRECT - 1 CFM @ IN. 42175NO. MOTORS - - 1/8 MOTOR SPEED COIL TYPESPINE FIN ROWS - - 24 FACE AREA (SQ. FT.) SIZE (IN.)3/8 REFRIGERANTR-22( UNIT) NP CHRG. 54/00-LB/OZFACTORY SUPPLIEDYESLINE SIZE - IN. GAS 63/4 LINE SIZE - IN.

7 LIQ. 65/16 FCCVRESTRICTOR ORIFICE X W X DOUTDOOR UNIT CRATED (IN.) X X OUTLINE (LBS.)169 NET (LBS.)150 CONDENSING UNIT WITH Cooling COILSCCBA30A4 ACCCBB30A4 ACCUBA30A4 ACCUBB30A4 ACTXA030C4 TXA031C4 TXA035C4 EXPANSION TYPEFIXED ORIFICEFIXED ORIFICEFIXED ORIFICEFIXED ORIFICECHG TO 65 CHG TO 65 CHG TO 65 RATINGS ( Cooling ) 1 BTUH (TOTAL)276002900027600290002900029000294 00 BTUH (SENSIBLE)198002130019800213002110021200 22000 INDOOR AIRFLOW (CFM)95010009501000100010001100 System POWER (KW) (BTU/WATT-HR.) TYPECHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 TXV-NBCHG TO 65 RATINGS ( Cooling ) 1 BTUH (TOTAL)302002900029000290002900030000294 00 BTUH (SENSIBLE)228002110021100212002120022000 22000 INDOOR AIRFLOW (CFM)1125100010001000100010001100 System POWER (KW) (BTU/WATT-HR.)

8 TYPECHG TO 65 CHG TO 65 CHG TO 65 TXV-NBTXV-NBCHG TO 65 CHG TO 65 RATINGS ( Cooling ) 1 BTUH (TOTAL)294003020030200312003120027800292 00 BTUH (SENSIBLE)220002280022800238002390019500 22000 INDOOR AIRFLOW (CFM)110011251125112511259001000 System POWER (KW) (BTU/WATT-HR.) IN ACCORDANCE WITH THE UNITARY AIR-CONDITIONEREQUIPMENT CERTIFICATION PROGRAM WHICH IS BASED STANDARD 210 IN ACCORDANCE WITH STANDARD IN ACCORDANCE WITH NATIONAL ELECTRIC USE HACR CIRCUIT BREAKERS OR AIR - DRY COIL - OUTDOOR5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNITNAMEPLATE AND SERVICE LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR -60 FT WITH SCROLL.

9 MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPINGSOFTWARE PUB. NO. VALUE SHOWN FOR COMPRESSOR RLA ON THE UNITNAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TOCOMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUMFUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUITSELECTION MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONENTSPTC MEANS POSITIVE TEMPERATURE COEFFICIENT IN ACCORDANCE WITH ARI STANDARD 270/SECTION SYSTEM822-1739-01-0402 (EN)GeneralData2 TTB0030A1000 ACONDENSING UNIT WITH AIR HANDLERSTVF030A14 TVF036A14 TWE030C14 TWE030P13 TWE036C14 TWE036P13 TWG030A14 EXPANSION TYPECHG TO 65 CHG TO 65 CHG TO 65 TXV-NBCHG TO 65 TXV-NBCHG TO 65 RATINGS ( Cooling ) 1 BTUH (TOTAL)300003100028600294003020030000288 00 BTUH (SENSIBLE)224002400020500213002330022800 21300 INDOOR AIRFLOW (CFM)10001125945940112511251000 System POWER (KW)

10 (BTU/WATT-HR.) TYPECHG TO 65 CHG TO 65 RATINGS ( Cooling ) 1 BTUH (TOTAL)2980029800 BTUH (SENSIBLE)2300023000 INDOOR AIRFLOW (CFM)11151115 System POWER (KW) (BTU/WATT-HR.) (EN)9 OUTDOOR UNIT 122 TTB0036A1000 ASOUND RATING (DECIBELS) 2980 POWER CONNS. V/PH/HZ 3200/230/1/60 MIN. BRCH. CIR. AMPACITY20BR. (AMPS)35 PROT. RTG. }MIN. (AMPS)30 COMPRESSORCLIMATUFF NO. USED - NO. SPEEDS1 - 1 VOLTS/PH/HZ200/230/1 AMPS 7 - - INSTALLEDSTART COMPONENTS 8 NOINSULATION/SOUND BLANKETNOCOMPRESSOR HEATNOOUTDOOR FAN TYPEPROPELLERDIA. (IN.) - NO. USED19 - 1 TYPE DRIVE - NO. SPEEDSDIRECT - 1 CFM @ IN. 42175NO. MOTORS - - 1/8 MOTOR SPEED COIL TYPESPINE FIN ROWS - - 24 FACE AREA (SQ.)