Example: dental hygienist

Stratix Ethernet Device Specifications Technical Data

Technical DataStratix Ethernet Device SpecificationsStratix 5400 Catalog Numbers 1783-HMS4C4 CGN, 1783-HMS8T4 CGN, 1783-HMS8S4 CGN, 1783-HMS4T4E4 CGN, 1783-HMS16T4 CGN, 1783-HMS4S8E4 CGN, 1783-HMS8TG4 CGN, 1783-HMS8SG4 CGN, 1783-HMS4EG8 CGN, 1783-HMS16TG4 CGN, 1783-HMS8TG8EG4 CGN, 1783-HMS4SG8EG4 CGN, 1783-HMS8TG4 CGR, 1783-HMS8SG4 CGR, 1783-HMS4EG8 CGR, 1783-HMS16TG4 CGR, 1783-HMS8TG8EG4 CGR, 1783-HMS4SG8EG4 CGR, Stratix 5410 Catalog Numbers 1783-IMS28 NDC, 1783-IMS28 NAC, 1783-IMS28 RDC, 1783-IMS28 RAC, 1783-IMXDC, 1783-IMXAC, Stratix 5700 Catalog Numbers 1783-BMS4S2 SGL, 1783-BMS4S2 SGA, 1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA, 1783-BMS06 SGL, 1783-BMS06 SGA, 1783-BMS06 TGL, 1783-BMS06 TGA, 1783-BMS10CL, 1783-BMS10CA, 1783-BMS10 CGL,1783-BMS10 CGA, 1783-BMS10 CGP, 1783-BMS10 CGN, 1783-BMS12T4E2 CGL, 1783-BMS12T4E2 CGP, 1783-BMS12T4E2 CGNK, 1783-BMS20CL, 1783-BMS20CA, 1783-BMS20 CGL, 1783-BMS20 CGP, 1783-BMS20 CGN, 1783-BMS20 CGPK, ArmorStratix 5700 Catalog Numbers 1783-ZMS8TA, 1783-ZMS16TA, 1783-ZMS24TA, 1783-ZMS4T4E2 TGP, 1783-ZMS8T8E2 TGP, 1783.

ArmorStratix 5700 Ethernet Managed Switches 21 Stratix 8000 and Stratix 8300 Ethernet Managed Switches 26 Stratix 6000 Ethernet Managed Switches 33 Embedded Switch Technology 36 Configurable NAT Router 40 Stratix 2000 Ethernet Unmanaged Switches 43 Stratix 5100 Wireless Access Point/Workgroup Bridge 49

Tags:

  Stratix, Managed, 0008, Switches, Ethernet, 0308, Stratix 8000, Stratix ethernet, Ethernet managed switches, Stratix 8300 ethernet managed switches

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Stratix Ethernet Device Specifications Technical Data

1 Technical DataStratix Ethernet Device SpecificationsStratix 5400 Catalog Numbers 1783-HMS4C4 CGN, 1783-HMS8T4 CGN, 1783-HMS8S4 CGN, 1783-HMS4T4E4 CGN, 1783-HMS16T4 CGN, 1783-HMS4S8E4 CGN, 1783-HMS8TG4 CGN, 1783-HMS8SG4 CGN, 1783-HMS4EG8 CGN, 1783-HMS16TG4 CGN, 1783-HMS8TG8EG4 CGN, 1783-HMS4SG8EG4 CGN, 1783-HMS8TG4 CGR, 1783-HMS8SG4 CGR, 1783-HMS4EG8 CGR, 1783-HMS16TG4 CGR, 1783-HMS8TG8EG4 CGR, 1783-HMS4SG8EG4 CGR, Stratix 5410 Catalog Numbers 1783-IMS28 NDC, 1783-IMS28 NAC, 1783-IMS28 RDC, 1783-IMS28 RAC, 1783-IMXDC, 1783-IMXAC, Stratix 5700 Catalog Numbers 1783-BMS4S2 SGL, 1783-BMS4S2 SGA, 1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA, 1783-BMS06 SGL, 1783-BMS06 SGA, 1783-BMS06 TGL, 1783-BMS06 TGA, 1783-BMS10CL, 1783-BMS10CA, 1783-BMS10 CGL,1783-BMS10 CGA, 1783-BMS10 CGP, 1783-BMS10 CGN, 1783-BMS12T4E2 CGL, 1783-BMS12T4E2 CGP, 1783-BMS12T4E2 CGNK, 1783-BMS20CL, 1783-BMS20CA, 1783-BMS20 CGL, 1783-BMS20 CGP, 1783-BMS20 CGN, 1783-BMS20 CGPK, ArmorStratix 5700 Catalog Numbers 1783-ZMS8TA, 1783-ZMS16TA, 1783-ZMS24TA, 1783-ZMS4T4E2 TGP, 1783-ZMS8T8E2 TGP, 1783-ZMS4T4E2 TGN, 1783-ZMS8T8E2 TGN, Stratix 8000 and Stratix 8300 Catalog Numbers 1783-MS06T, 1783-MS10T, 1783-RMS06T, 1783-RMS10T, 1783-MX04E, 1783-MX04T04E, 1783-MX04S, 1783-MX08S, 1783-MX08T, 1783-MX08F, Stratix 6000 Catalog Numbers 1783-EMS08T, 1783-EMS04T, Embedded Switch Technology Catalog Numbers 1783-ETAP, 1783-ETAP1F, 1783-ETAP2F.

2 Configurable NAT Router Catalog Number 1783-NATR, Stratix 2000 Catalog Numbers 1783-US4T1F, 1783-US4T1H, 1783-US5T, 1784-US5TG, 1783-US6T2F, 1783-US6T2H, 1783-US6TG2CG, 1783-US7T1F, 1783-US7T1H, 1783-US8T, 1783-US14T2S, 1783-US16T, Stratix 5100 Catalog Numbers 1783-WAPAK9, 1783-WAPEK9, 1783-WAPZK9, 1783-WAPCK9, Stratix 5900 Catalog Number 1783-SRTopicPageStratix 5400 Ethernet managed Switches2 Stratix 5410 Ethernet managed Switches6 Stratix 5700 Ethernet managed Switches12 ArmorStratix 5700 Ethernet managed Switches21 Stratix 8000 and Stratix 8300 Ethernet managed Switches26 Stratix 6000 Ethernet managed Switches33 Embedded Switch Technology36 Configurable NAT Router40 Stratix 2000 Ethernet Unmanaged Switches43 Stratix 5100 Wireless Access Point/Workgroup Bridge49 Stratix 5900 Services Router51 Accessories54 Additional Resources562 Rockwell Automation Publication 1783-TD001K-EN-P - August 2015 Stratix Ethernet Device SpecificationsSummary of ChangesThis manual contains new and updated information.

3 Changes throughout this revision are marked by change bars, as shown to the left of this 5400 Ethernet managed SwitchesTopicPageStratix 5410 switches6 Cat. PortsRJ45 Ports(1)(1)FE = Fast Ethernet ; GE = Gigabit Ports (PoE/PoE+)SFP SlotsFirmware TypeCIP Sync (IEEE 1588)NAT1783-HMS4C4 CGN8 4 FE, 4 GE Layer 2 YesYes1783-HMS8T4 CGN128 FE4 GE Layer 2 YesYes1783-HMS8S4 CGN12 4 GE 8 FELayer 2 YesYes1783-HMS4T4E4 CGN124 FE4 GE4 FE Layer 2 YesYes1783-HMS4S8E4 CGN16 4 GE8 FE4 FELayer 2 YesYes1783-HMS16T4 CGN2016 FE4 GE Layer 2 YesYes1783-HMS8TG4 CGN128 GE4 GE Layer 2 YesYes1783-HMS8SG4 CGN12 4 GE 8 GELayer 2 YesYes1783-HMS4EG8 CGN12 8 GE4 GE Layer 2 YesYes1783-HMS4SG8EG4 CGN16 4 GE8 GE4 GELayer 2 YesYes1783-HMS16TG4 CGN2016 GE4 GE Layer 2 YesYes1783-HMS8TG8EG4 CGN208 GE4 GE8 GE Layer 2 YesYes1783-HMS8TG4 CGR128 GE4 GE Layer 3 YesYes1783-HMS8SG4 CGR12 4 GE 8 GELayer 3 YesYes1783-HMS4EG8 CGR12 8 GE4 GE Layer 3 YesYes1783-HMS4SG8EG4 CGR16 4 GE8 GE4 GELayer 3 YesYes1783-HMS16TG4 CGR2016 GE4 GE Layer 3

4 YesYes1783-HMS8TG8EG4 CGR208 GE4 GE8 GE Layer 3 YesYesRockwell Automation Publication 1783-TD001K-EN-P - August 20153 Stratix Ethernet Device SpecificationsTable 1 - Technical Specifications - Stratix 5400 SwitchesAttribute1783-HMS8T4 CGN,1783-HMS16T4 CGN,1783-HMS8TG4 CGN, 1783-HMS8TG4 CGR1783-HMS4C4 CGN,1783-HMS16TG4 CGN, 1783-HMS16TG4 CGR1783-HMS8S4 CGN, 1783-HMS8SG4 CGN, 1783-HMS8SG4 CGR1783-HMS4T4E4 CGN1783-HMS4S8E4 CGN, 1783-HMS8TG8EG4 CGN1783-HMS4SG8EG4 CGN,1783-HMS4EG8 CGN,1783-HMS4SG8EG4 CGR, 1783-HMS8TG8EG4 CGR1783-HMS4EG8 CGRA larm relay ratings1 A @ 30V DC or A @ 48V DCPower A max @ A max @ A max @ A max @ A max @ DCPower over Ethernet (PoE) input power DC for DC for PoE+ or a combination of PoE and PoE+Power consumption35 W @ 24V DC @ 40 C (104 F)40 W @ 24V DC @ 40 C (104 F)42 W @ 24V DC @ 40 C (104 F)35 W @ 24V DC @ 40 C (104 F)PoE power at 50V: 120 W40 W @ 24V DC @ 40 C (104 F)PoE power at 50V: 124 WIsolation voltage60V (continuous), basic insulation type, all ports to groundNo isolation between individual portsType tested at 500V AC for 60 sDC power mm2 ( AWG) solid or stranded copper wire rated at 30 C (86 F), or greater, above the surrounding air mm ( in.)

5 Mm ( in.) strip lengthAlarm mm2 ( AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire, mm( in.) mm ( in.) strip lengthGround connection4 mm2 (10 AWG) solid or stranded copper wireSFP modules1783-SFP100FX1783-SFP1 GSX1783-SFP100LX1783-SFP1 GLXM emory card replacement1784-SD1 Screw torque, ground N m ( lb in)Screw torque, power N m ( lb in)Screw torque, alarm N m ( lb in)Weight, kg ( lb)Wiring category(1)(1)Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication - on console ports2 - on DC power and alarm portsEnclosure type ratingNone (open-style)Pilot duty ratingAlarm not ratedNorth American temp codeT3 ATEX temp codeT34 Rockwell Automation Publication 1783-TD001K-EN-P - August 2015 Stratix Ethernet Device SpecificationsTable 2 - Environmental Specifications - Stratix 5400 switches AttributeStratix 5400 SwitchesTemperature, operatingIEC 60068-2-1 (Test Ad, Operating Cold),IEC 60068-2-2 (Test Bd, Operating Dry Heat),IEC 60068-2-14 (Test Nb, Operating Thermal Shock) C ( F)Temperature, surrounding air, max70 C (158 F)

6 Temperature, nonoperatingIEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) C ( F)Relative humidityIEC 60068-2-30 (Test Db, Unpackaged Damp Heat) noncondensingVibrationIEC 60068-2-6 (Test Fc, Operating)1 g @ HzShock, operatingIEC 60068-2-27 (Test Ea, Unpackaged Shock)15 gShock, nonoperatingIEC 60068-2-27 (Test Ea, Unpackaged Shock)30 gEmissionsIEC 61000-6-4 IEC 61000-6-4 ESD immunityIEC 61000-4-26 kV contact discharges8 kV air dischargesRadiated RF immunityIEC 61000-4-320V/m with 1 kHz sine-wave 80% AM from MHz10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz20V/m with 1 kHz sine-wave 80% AM from MHzEFT/B immunityIEC 61000-4-4 3 kV at 5 @ 100 kHz on DC power ports 3 kV at 5 @ 100 kHz on alarm ports 3 kV at 5 @ 100 kHz on Ethernet portsSurge transient immunityIEC 61000-4-5 1 kV line-line (DM) and 2 kV line-earth (CM) on DC power ports 1 kV line-line (DM) and 2 kV line-earth (CM) on alarm ports 2 kV line-earth(CM)

7 On Ethernet portsConducted RF immunityIEC 61000-4-610V rms with 1 kHz sine-wave 80% AM from 150 MHzMagnetic field immunityIEC 61000-4-8300 A/m long duration and 1000 A/m short duration at 50 @ 60 HzVoltage variationIEC 61000-4-2910 ms interruption on DC power portsDamped oscillatory wave immunityIEC 61000-4-18 1 kV line-line (DM) and kV line-earth (CM) on power and alarm ports kV line-earth (CM) on Ethernet portsRockwell Automation Publication 1783-TD001K-EN-P - August 20155 Stratix Ethernet Device SpecificationsDimensions Stratix 5400 SwitchesTo prevent the switch from overheating, observe the following minimum clearances: Top and bottom: mm ( in.) Sides: mm ( in.) Front: mm ( in.)These diagrams are representative of the Stratix 5400 switches .

8 Actual faceplates vary depending on the catalog 3 - Certifications - Stratix 5400 SwitchesCertifications (when product is marked)(1) Stratix 5400 Switchesc-UL-usUL Listed Industrial Control Equipment, certified for US and Canada. See UL File Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for and Canada. See UL File Listed for Class I, Zone 2 Hazardous Locations, certified for and Canada. See UL File nA nC IIC T3 Gc XAEx nA nC IIC T3 GcCEEuropean Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; , Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)European Union 2011/65/EU RoHS, compliant with: EN 50581; Technical DocumentationRCMA ustralian Radiocommunications Act, compliant with:ACMA EMC Std 08 ExEuropean Union 94/9/EC ATEX Directive, compliant with: EN 60079-0; General Requirements EN 60079-15.

9 Potentially Explosive Atmospheres, Protection "n" II 3 G Ex nA nC IIC T3 Gc DEMKO14 ATEX1423 XEtherNet/IPODVA conformance tested to Ethernet /IP Specifications (1)See the Product Certification link at for declarations of conformity, certificates, and other certification cm( in.) cm( in.) cm( in.) cm ( in.) cm( in.) cm( in.) cm( in.)6 Rockwell Automation Publication 1783-TD001K-EN-P - August 2015 Stratix Ethernet Device SpecificationsStratix 5410 Ethernet managed SwitchesCat. Ports (PoE/PoE+)SFP Slots(2)(2)GE = Gigabit Ethernet ; TEN = 10 Gigabit EthernetFirmware TypeCIP Sync (IEEE 1588)NATP ower supply(3)(3)One power supply ships pre-installed in each Stratix 5410 switch. 1783-IMS28 NDC2812 GE12 GE + 4 TENL ayer 2 YesYesLow DC1783-IMS28 NAC2812 GE12 GE + 4 TENL ayer 2 YesYesAC/High DC1783-IMS28 RDC2812 GE12 GE + 4 TENL ayer 3 YesYes (Layer 2)Low DC1783-IMS28 RAC2812 GE12 GE + 4 TENL ayer 3 YesYes (Layer 2)AC/High DCOptional Power Supplies(1)(1)The switch supports an optional second power supply of any voltage type to provide redundancy and additional power for PoE devices.

10 One power supply provides 60 W for PoE/PoE+. Two power supplies provide 185 W for PoE/PoE+.1783-IMXDCLow DC1783-IMXACAC/High DCTable 4 - Technical Specifications - Stratix 5410 switches Attribute1783-IMS28 NDC, 1783-IMS28 RDC1783-IMS28 NAC, 1783-IMS28 RACA larm relay30V DC, 1 A or 48V DC, APower DC, 10 AC, 2 A, Hz (per slot) or DC, 12 A (per slot)PoE output54V DC, W maxPoE+ output(1)54V DC, 30 W maxPower consumptionOne power supply installed:No PoE ports on: 74 W @ 24V DC @ 40 C (104 F), 76 W max4 PoE ports on, 148 W max: 145 W @ 24V DC @ 40 C (104 F)Two power supplies installed:PoE power consumption alone (12 ports PoE): 210 W@ 24V DC @ 40 C (104 F); 215 W maxComplete system power, including 12 ports PoE: 291 W maxOne power supply installed:No PoE ports on: 74 W @ 120V,60Hz / 230V, 50Hz AC @ 40 C (104 F), 76W max4 PoE ports on, 148 W max: 145W @ 120V,60Hz / 230V, 50Hz AC @ 40 C (104 F) Two power supplies install