Example: confidence

SUBMITTAL DATA SHEET - …

SUBMITTAL DATA SHEETCONDENSING HIGH EFFICIENCY UPFLOW TWO STAGE GAS FURNACESMODELS: FC9T Unitary Products Group036-22876-002 Rev. A (1205)JOB NAME: LOCATION:PURCHASER:ORDER NO:ENGINEER: SUBMITTED TO:FOR: REF:APPROVAL:CONSTRUCTION:SUBMITTED BY:DATE:UNIT DESIGNATION:SCHEDULE DATAH eating PerformanceInput Capacity _____ MBHO utput Capacity _____ MBHAir Temp. Rise_____ F Supply Air Blower PerformanceTotal Supply Air_____CFMT otal External Static Pressure _____ IWGB lower Speed (circle) _____HI MH ML LMotor Rating _____HPElectrical DataPower Supply _____/__/__ Total Unit Ampacity _____AMPSM inimum Wire Size _____AWGM aximum Overcurrent Device Fuses Circuit Breaker____AMPSUnit WeightTotal Unit Weight _____LBSCLEARANCESTo p1 Front3 Vent Pipe0 Rear0L & R Sides0 BottomMay be a

CONCENTRIC VENT TERMINATION - 1CT0302 (2") 1CT0303 (3") For use through rooftop, sidewall. Allows combustion air to enter and exhaust to …

Tags:

  Vents, Concentric, 1ct0302, 1ct0303, Concentric vent

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SUBMITTAL DATA SHEET - …

1 SUBMITTAL DATA SHEETCONDENSING HIGH EFFICIENCY UPFLOW TWO STAGE GAS FURNACESMODELS: FC9T Unitary Products Group036-22876-002 Rev. A (1205)JOB NAME: LOCATION:PURCHASER:ORDER NO:ENGINEER: SUBMITTED TO:FOR: REF:APPROVAL:CONSTRUCTION:SUBMITTED BY:DATE:UNIT DESIGNATION:SCHEDULE DATAH eating PerformanceInput Capacity _____ MBHO utput Capacity _____ MBHAir Temp. Rise_____ F Supply Air Blower PerformanceTotal Supply Air_____CFMT otal External Static Pressure _____ IWGB lower Speed (circle) _____HI MH ML LMotor Rating _____HPElectrical DataPower Supply _____/__/__ Total Unit Ampacity _____AMPSM inimum Wire Size _____AWGM aximum Overcurrent Device Fuses Circuit Breaker____AMPSUnit WeightTotal Unit Weight _____LBSCLEARANCESTo p1 Front3 Vent Pipe0 Rear0L & R Sides0 BottomMay be applied directly on a combustible floorDIMENSIONS - INCHESM odelsNominalCFMC abinetSizeCabinet DimensionA (in.)

2 B (in.)C (in.)D (in.)FC9T040A12UP111200A14-1/213-1/412-1 /86-1/4FC9T060B12UP111200B17-1/216-1/415 -1/88-1/2FC9T080B12UP111200B17-1/216-1/4 15-1/88-1/2FC9T080C16UP111600C2119-3/418 -1/28-7/8FC9T100C16UP111600C2119-3/418-1 /28-7/8FC9T100C20UP112000C2119-3/418-1/2 8-7/8FC9T120D20UP112000D24-1/223-1/421-7 /810-5/830-7/821-1/213-7/87117/823-3/47/ 830-1/826-1/224-5/8A4026-1/225-3/828-3/8 21-1/211826-3/41-3/81-1/4C24-3/8205/85/8 B24-7/162D1-1/2 GASPIPE ENTRY7/8 JUNCTIONBOX HOLET-STAT WIRING7/8 7/8 RETURN AIRCUT-OUT (either side)FOR USE WITHEXTERNAL FILTERFRAMELEFT SIDEFRONTRIGHT SIDEBOTTOM IMAGERETURN ENDTOP IMAGESUPPLY END1-1/2 GASPIPE ENTRY7/8 JUNCTIONBOX HOLET-STAT WIRING7/8 7/8 9001 Certified QualityManagement SystemSubject to change without notice.

3 Printed in Rev. A (1205)Copyright by York International Corp. 2005. All rights reserved. Supersedes: 036-22876-001 Rev. C (0205)Unitary5005 NormanProductsYorkOKGroupDrive73069 FEATURES Compact, easy to install, ideal height 40" cabinet. May be installed as either two-pipe (sealed combustion) or single-pipe vent (using indoor combustion air) Blower-off delay for cooling SEER improvement. Easy to connect power/control wiring. Built-in, high level self diagnostics with fault code display. Low unit amp requirement for easy replacement application. Integrated control module for reliable, economical operation. Insulated blower compartment for quiet operation. Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.

4 Induced combustion system with inshot main burners for quiet, efficient operation. No special vent termination kit required. 100% shut off main gas valve for extra safety. PSC - four speed, direct drive motor with large, quiet blower. 24V, 40 VA control transformer and blower relay supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger. Secondary (condensing) heat exchanger of 29-4C high-grade stainless steel. Timed on, adjustable off blower capability for maximum comfort. Internal vent coupling for maximum serviceability. Solid removable bottom panel allows easy application. Independent door removal for greater durability and ease of access. Two stage heating capacity for better overall INSTALLED ACCESSORIESCONCENTRIC VENT TERMINATION - 1ct0302 (2") 1ct0303 (3")For use through rooftop, sidewall.

5 Allows combustion air toenter and exhaust to exit through single common (LP) CONVERSION KIT - 1NP0580 - All unitsThis accessory conversion kit may be used to convert naturalgas (N) units for propane (LP) operation. Conversions mustbe made by qualified distributor or dealer NEUTRALIZER KIT - 1NK0301 Neutralizer cartidge has a 1/2" plastic tube fittings for installa-tion in the drain line. Calcium carbonate refill media is alsoavaiable from the Source 1 Parts (p/n 026-30228-000).SIDEWALL VENT TERMINATION - 1HT0901 For use on sidewall, two-pipe installations only. Provides amore attractive termination for locations where the terminal isvisible on the side of the SIDE RETURN FILTER RACK -1SF0101 - Fits all cabinet sizesAttaches to side of furnace cabinet in side return applica-tions.

6 Holds any 16x25x1 permanent or disposable RETURN FILTER - 1SR0302 - All Models1SR0200 - All ModelsBOTTOM RETURN FILTER - 1BR0114 or 1BR0214 - For 14-1/2 cabinets1BR0117 or 1BR0217 - For 17-1/2 cabinets1BR0121 or 1BR0221 - For 21 cabinets1BR0124 or 1BR0224 - For 24-1/2 cabinetsINTERNAL FILTER WITH FIBER FILTER - 1HF0801 - All ModelsHIGH ALTITUDE PRESSURE SWITCHES - For installation where the altitude is less than 8,000 feet it isnot required that the pressure switch be changed. For alti-tudes above 8,000 feet see kits below. Conversion must bemade by qualified distributor or dealer - 060 MBH1PS0502 - 080/1200 MBH1PS0503 - 080/1600, 100/1600, 120 MBH1PS0505 - 100/2000 MBH1PS0506 - 040 MBHINTAKE/VENT SIZING - TWO PIPE SYSTEM* Three elbows (two in vent pipe and one in the air intake pipe)

7 Are already accounted for and need not be included in the elbow count from the Table ELBOWS AND VENT LENGTHSM odels Input BTUHPipe Size InchesMaximum Number of Elbows* Minimum Length1234567840,0001-1/230252010N/AN/AN /AN/A540,00027065605550453525560,0001-1/ 230252010N/AN/AN/AN/A560,000260555045403 02010560,000385807570656050402080,0001-1 /22015N/AN/AN/AN/AN/AN/A580,0002 6055504540302010580,00038580757065605040 20100,0002252015N/AN/AN/AN/AN/A5100,0003 858075706560504020120,000375706560554535 255