Example: quiz answers

Sync Smart Switch - Honeywell Generators

Transfer Switches sync Smart Switch with Load Shedding Capacity Service and Non-Service Rated 100 400 Amp, Single Phase NEMA 3R. Features Honeywell sync Switches are designed for use with single phase Generators . The 100, 150, 200, and 400 amp open transition switches are available in single phase in both service rated and non-service rated configurations. All Honeywell sync Switches are housed in an aluminum NEMA/UL. Type 3R enclosure*, with electrostatically applied and baked powder paint. The control at the generator handles all the timing, sensing, and exercising functions. The Heavy Duty Honeywell Contactor is a UL. recognized device, designed for years of service. DPM Technology (single phase switches only) Through the use of digital power technology (DPM), each Switch has the capability to manage up to four individual HVAC (24V controlled) loads with no additional hardware. When used in tandem with Smart Management modules, up to eight more loads can be managed as well, providing the most installation efficient power management options available.

switch mounting, to increase installation flexibility. • Automatic transfer switch operation for hands free generator functionality when the utility power falls below acceptable levels. Sync™ Smart Switch with Load Shedding Capacity Service and Non-Service Rated 100–400 Amp, Single Phase NEMA 3R …

Tags:

  Switch, Smart, Sync, Sync smart switch

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Sync Smart Switch - Honeywell Generators

1 Transfer Switches sync Smart Switch with Load Shedding Capacity Service and Non-Service Rated 100 400 Amp, Single Phase NEMA 3R. Features Honeywell sync Switches are designed for use with single phase Generators . The 100, 150, 200, and 400 amp open transition switches are available in single phase in both service rated and non-service rated configurations. All Honeywell sync Switches are housed in an aluminum NEMA/UL. Type 3R enclosure*, with electrostatically applied and baked powder paint. The control at the generator handles all the timing, sensing, and exercising functions. The Heavy Duty Honeywell Contactor is a UL. recognized device, designed for years of service. DPM Technology (single phase switches only) Through the use of digital power technology (DPM), each Switch has the capability to manage up to four individual HVAC (24V controlled) loads with no additional hardware. When used in tandem with Smart Management modules, up to eight more loads can be managed as well, providing the most installation efficient power management options available.

2 * The 400 amp Non-Service Rated Switch is housed in a steel enclosure. F E AT U R E S & B E N E F I T S. Corrosion resistant Knockout free NEMA 3R enclosure enclosure and enclosure increases allows for internal or components stand up installation external transfer against the elements. flexibility no need to Switch mounting, to worry about existing increase installation Color coded factory created flexibility. connection points for knockouts when easy generator Automatic transfer determining knockout connection reduce Switch operation for location. time and improve hands free generator installation flexibility. functionality when the utility power falls below acceptable levels. sync Smart Switch Technical Specifications FUNCTIONS All other trademarks All timing and sensing functions originate in the Re-transfer time delay: 15 seconds are the property of their respective owners. generator controller. Engine cool-down timer: 60 seconds*.

3 Utility voltage drop-out: < 65% Exerciser: 5 minutes bi-weekly factory set, Timer to generator start: 5 second factory set, adjustable for weekly and monthly adjustable between 2-1500 seconds by a qualified The transfer Switch can be operated manually dealer* without power applied. Engine warm up delay: 5 seconds * Default settings may vary by model; see owner's Utility voltage pick up: > 80% manual for settings. EXTERNAL DIMENSIONS W1. 100 AMPS 120/240, 1 OPEN TRANSITION. HEIGHT WEIGHT DEPTH. H2 H1. H1 H2 W1 W2. Inches 20 mm 508 DEPTH W2. 100 AMPS 120/240, 1 OPEN TRANSITION SERVICE RATED W1. HEIGHT WEIGHT DEPTH. H1 H2 W1 W2. Inches 20 mm 508 H2 H1. 200 AMPS 120/240, 1 OPEN TRANSITION. HEIGHT WEIGHT DEPTH. H1 H2 W1 W2. Inches 20 mm 508 DEPTH W2. 150 & 200 AMPS 120/240, 1 OPEN TRANSITION SERVICE RATED. HEIGHT WEIGHT DEPTH. H1 H2 W1 W2. Inches mm 762 400 AMPS 120/240, 1 OPEN TRANSITION. HEIGHT WEIGHT DEPTH. H1 H2 W1 W2. Inches mm 300 & 400 AMPS 120/240, 1 OPEN TRANSITION SERVICE RATED.

4 HEIGHT WEIGHT DEPTH. H1 H2 W1 W2. Inches mm sync Smart Switch Technical Specifications RXSK100A3 RXSM200A3 * Automatic AMPS 100 AMPS 200. VOLTAGE 120/240, 1 VOLTAGE 120/240, 1 . LOAD TRANSITION TYPE* Open transition LOAD TRANSITION TYPE* Open transition service rated ENCLOSURE TYPE NEMA 3R ENCLOSURE TYPE NEMA 3R. UL RATING UL/CUL UL RATING UL. WITHSTAND RATING (AMPS) 10,000 WITHSTAND RATING (AMPS) 22,000. LUG RANGE 2/0 #14 LUG RANGE 400 MCM #4. UNIT WEIGHT: UNIT WEIGHT: LBS 20 LBS 39. KG KG RXSM100A3 RXSM300A3. AMPS 100 AMPS 300. VOLTAGE 120/240, 1 VOLTAGE 120/240, 1 . LOAD TRANSITION TYPE* Open transition service rated LOAD TRANSITION TYPE* Open transition service rated ENCLOSURE TYPE NEMA 3R ENCLOSURE TYPE NEMA 3R. UL RATING UL UL RATING UL. WITHSTAND RATING (AMPS) 10,000 WITHSTAND RATING (AMPS) 22,000. LUG RANGE 2/0 #14 LUG RANGE 600 MCM #4, or 2-250 MCM. UNIT WEIGHT: UNIT WEIGHT: LBS LBS 140. KG KG RXSM150A3 RXSK400A3. AMPS 150 AMPS 400.

5 VOLTAGE 120/240, 1 VOLTAGE 120/240, 1 . LOAD TRANSITION TYPE* Open transition service rated LOAD TRANSITION TYPE* Open transition ENCLOSURE TYPE NEMA 3R ENCLOSURE TYPE NEMA 3R. UL RATING UL UL RATING UL/CUL. WITHSTAND RATING (AMPS) 22,000 WITHSTAND RATING (AMPS) 18,000. LUG RANGE 400 MCM #4 LUG RANGE 600 MCM #4, or 2-250 MCM. UNIT WEIGHT: UNIT WEIGHT: LBS 39 LBS 133. KG KG RXSK200A3 RXSM400A3. AMPS 200 AMPS 400. VOLTAGE 120/240, 1 VOLTAGE 120,240, 1 . LOAD TRANSITION TYPE* Open Transition LOAD TRANSITION TYPE * Open transition service rated ENCLOSURE TYPE NEMA 3R ENCLOSURE TYPE NEMA 3R. UL RATING UL/CUL UL RATING UL. WITHSTAND RATING (AMPS) 10,000 WITHSTAND RATING (AMPS) 22,000. LUG RANGE 400 MCM #4 LUG RANGE 600 MCM #4, or 2-250 MCM. UNIT WEIGHT: UNIT WEIGHT. LBS 20 LBS 140. KG KG Generac Power Systems, Inc. Generac Power Systems, Inc. All rights reserved. Specifications subject to change without notice. S45 W29290 Hwy 59. Waukesha, WI.

6 53187 The Honeywell trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation or warranties with respect to this product. This product is manufactured by Generac Power Systems, Inc., Waukesha, WI 53187, USA. Part No. 10000013986 Revision A (09/13/17).