TAC I/A Series JACE 645 Network Controller

1 TAC I/A in. W x in. H x in. D(248 mm x 295 mm x 64 mm) lbs ( kg) with parts lbs ( kg) as for indoor wall mounting only. When mounting, add clearance of 2 in. (51 mm) at top and bottom, and 1 in. (25 mm) on left and right air convection (vertical mounting required).PLATFOrMMicroprocessorEmbedded PowerPC 440 Platform at 524 MB RAM, Optional 256 MB RAM (G3)128 MB Flash for database SystemOperating System with IBM J9 Java Virtual Machine.(R2) or Sun Hotspot JVM (G3)Requires Niagara R2 or higher; or Niagara G3 or continued on next 645 Series Network ControllerTAC I/A Series jace 645 The TAC I/A Series jace 645 Network Controller is a compact, embedded-processor platform with flash memory for backup. The jace 645 provides integrated control, supervision, and Network management solutions for a Network of LonWorks -based, BACnet-based, or Modbus-based controllers for building control.

The TAC I/A SeriesJACE 645 Network Controller is a compact, embedded-processor platform with flash memory for backup. The JACE 645 provides integrated control, supervision, and network management solutions for a network of LonWorks™-based, BACnet-based, or Modbus-based controllers

Tags:

  Series, Jace, Tac i a series jace, Tac i a series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TAC I/A Series JACE 645 Network Controller

1 1 TAC I/A in. W x in. H x in. D(248 mm x 295 mm x 64 mm) lbs ( kg) with parts lbs ( kg) as for indoor wall mounting only. When mounting, add clearance of 2 in. (51 mm) at top and bottom, and 1 in. (25 mm) on left and right air convection (vertical mounting required).PLATFOrMMicroprocessorEmbedded PowerPC 440 Platform at 524 MB RAM, Optional 256 MB RAM (G3)128 MB Flash for database SystemOperating System with IBM J9 Java Virtual Machine.(R2) or Sun Hotspot JVM (G3)Requires Niagara R2 or higher; or Niagara G3 or continued on next 645 Series Network ControllerTAC I/A Series jace 645 The TAC I/A Series jace 645 Network Controller is a compact, embedded-processor platform with flash memory for backup. The jace 645 provides integrated control, supervision, and Network management solutions for a Network of LonWorks -based, BACnet-based, or Modbus-based controllers for building control.

2 When connected over an Ethernet Network , the jace 645 can communicate and share data between LonWorks, BACnet, and Modbus complete set of Java - based control, application, logging, and user interface objects are included in a library. With the Web User Interface Service, the system s graphical views can be accessed using any standard Web browser, such as Microsoft Internet Explorer or Mozilla Firefox .ApplicationsSpecifically designed for mechanical room, factory floor, and other commercial environments. The jace 645 is wall-mounted, using its integral metal a small building application, a single jace can be used to support a Network of BACnet, LonWorks, or Modbus devices that can be accessed directly over the Ethernet LAN, or remotely over the jace 645 is a direct replacement for the UNC 520 and ENC 520 Series Network controllers and can be licensed to run in either an R2 or G3 Niagara Framework application environment.

3 Note that both R2 and G3 environments cannot be active at the same time and there is no R2 to G3 conversion tool. Therefore, to migrate from R2 to G3 environments the entire application must be re-engineered including of the jace 645 are available for retrofit applications that permit re-use of existing UNC/ENC power supplies and enclosures. Parts TRD-RB-645-R2 and TRD-RB-645 are retrofit boards for the UNC 520 and ENC 520 Series controllers 645 Series Enterprise Network ControllerSchneider Electric | Buildings 1-888-444-1311F-27842-1 November 2013 tl 2013 Schneider Electric. All rights I/A SeriesSpecifications continued from first backup. ClockReal-time Power SupplyTrd-T-645-r2, Trd-T-645 120 Vac, 50/60 Hz, 25 VA max.

4 Lead wires for hot/neutral (wire nut), stud for ground 230 Vac, 50/60 Hz, 25 VA max. Terminal block for hot/neutral, stud for ground , Trd-rB-645 Existing UNC or ENC power Temperature32 to 122 F (0 to 50 C)Shipping and Storage Temperature32 to 158 F (0 to 70 C)Humidity5 to 95% RH, non-condensingBATTEry BACkuPBattery Backup provided for all onboard is monitored and trickle charged. Expected battery life is three years. In environments outside of recommended temperature range, battery life expectancy is one is a registered trademark of ASHRAE. ASHRAE does not endorse, approve, or test products for compliance with ASHRAE standards. Compliance of listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet International (BI).

5 BTL is a registered trademark of maintains processor operation through power failures for a predetermined interval, then writes all data to flash memory, shuts processor down, and maintains clock for a minimum of 5 LISTINGSuSFCC Part 15, Class BUL 916 CanadianUL Listed to Canadian Safety Standards (CAN/CSA ). No. 205-M 1983, Signaling Equipment. RoHS requirements to bear the C-Tick MarkEuropean CommunityEMC Directive 89/336/EEC, EN50081-1 (EMC Immu-nity), EN50082-1 (AC Mains Power Line Voltage).COMMuNICATIONS Two 10/100 Mbit Ethernet ports. RJ-45 connector. R2 applications limited to use of one Ethernet port. Four RS-485 ports (up to Kbaud). Three-position screw terminal connectors, electrically isolated. Two RS-232 ports.

6 RJ-45 connectors. One LonWorks port FTT-10A (up to 78 kbps). Two-pin Weidmuller connector, electrically COMPLIANCEBACnet Building Controller (B-BC).FEATurES Integral BACnet, BACnet/Ethernet, and BACnet MS/TP communications support. Integral LonWorks communications support. Embedded RISC Microprocessor platform provides high computing speeds. Distributes real-time data across an Ethernet LAN. Provides alarming, logging, scheduling, control, and custom HVAC applications. Password-protected access. Web User Interface supports many simultaneous users over Intranet or Internet, via standard Web 645 Series Enterprise Network ControllerSchneider Electric | Buildings 1-888-444-1311F-27842-1 November 2013 tl 2013 Schneider Electric.

7 All rights I/A SeriesMOdELSPart NumberreplacesdescriptionTRD-T-645-R2 UNC-520-2 Network Controller with enclosure and 120 VAC, 25 VA power supply; includes R2 licenseTRD-T-645 ENC-520-2 Network Controller with enclosure and 120 VAC, 25 VA power supply; includes G3 licenseTRD-T-645-NENC-520-2-NNetwork Controller with enclosure and 230 VAC, 25 VA power supply; includes G3 licenseTRD-RB-645-R2 UNC-520-2 UNC-520-2-N (Retrofit) Network Controller Retrofit Board for UNC 520; includes R2 licenseTRD-RB-645 ENC-520-2 ENC-520-2-N (Retrofit) Network Controller Retrofit Board for ENC 520; includes G3 licenseAll non-retrofit models include the following: Features: Web user interface, Enterprise Connectivity Pack (P2P) Drivers: BACnet IP, BACnet over Ethernet, BACnet MS/TPa, LONworks, oBIX Client/Server and SSLFor retrofits, all drivers and options active on the original UNC or ENC Controller (where applicable) will be transferred to the replacement board.

8 Memory expansion is NOT included in the base unit. Retrofit upgrade of an ENC-520 with 256 RAM will also require the purchase of the TRD-NPM-256 memory expansion TRD-T-645-R2 includes one trunk of BACnet MS/TP. Additional trunks can be purchase as ONLy OPTIONSPart NumberdescriptionTRD-R2-6 XXAdd R2 application license to TRD-T-603 (-N) or TRD-T-645 (-N) Network controllerTRD-R2-RB-6 XXAdd R2 application license to TRD-RB-603 or TRD-RB-645 Network Controller (retrofit board)IA-DRV-ASDASD device driver for direct ASD Bus support; includes tunnel support for XPSIIA-DRV-DMS-EDMS serial device driver; includes tunnel support for OPRIFIA-DRV-MS31 MicroSmart device driver; for direct MicroSmart Bus support of 31 controllers on a single trunk; includes tunnel support for OPRIF Level 9/10/11 firmware device driver; same as above but supports 62 controllersIA-DRV-MS93 MicroSmart device driver.

9 Same as above but supports 93 controllersIA-DRV-MS124 MicroSmart device driver; same as above but supports 124 controllersIA-DRV-LCML ocal Control Module (LCM) device driver; supports up to 31 LCMs on a single networkIA-DRV-MST-PBACnet MSTP device driver; direct BACnet MSTP supportIA-DRV-MODM odbus device driver; direct Modbus supportIA-DRV-MOD-SModbus slave device driver; Modbus slave using RTU protocolIA-DRV-MOD-TModbus Client device driver; Modbus TCP support; Modbus client, using Ethernet TCPIA-DRV-MOD-RModbus Server device driver; Modbus TCP support; Modbus server using Ethernet TCPIA-DRV-NW8-ENETWORK 8000 serial device driver; includes tunnel support for XPSIIA-DRV-SNM-PSimple Network Management Protocol (SNMP) driver4 jace 645 Series Enterprise Network ControllerSchneider Electric | Buildings 1-888-444-1311F-27842-1 November 2013 tl 2013 Schneider Electric.

10 All rights I/A SeriesG3 ONLy OPTIONSPart NumberdescriptionTRD-G3-6 XXAdd G3 application license to TRD-T-603-R2 or TRD-T-645-R2 Network controllerTRD-G3-RB-6 XXAdd G3 application license to TRD-RB-603-R2 or TRD-RB-645-R2 Network Controller (retrofit board)TRD-NPM-256 Upgrade RAM license 128 to 256 MB Increases JAVA heap 48MB to 96MB (G3 stations only)ENC-DRV-ASDASD device driver for direct ASD Bus support; includes tunnel support for XPSIENC-DRV-DMSDMS serial device driver; includes tunnel support for OPRIFENC-DRV-ILOND river for LON over IP using CEA-852; communicates through an IP/LON routerENC-DRV-EIBEIB/Konnex IP driver designed to connect to an EIB/KNX Network via an IP to EIB interfaceENC-DRV-FLEXC onfigurable Flex driver, over RS-232 or RS-485 ENC-DRV-MBUSM anages an M-Bus Network via an RS-232 to M-Bus interfaceENC-DRV-SMSE nables SMS alarms to be sent to any mobile phone via a GSM/GPRS modem connected to the RS-232 serial portENC-DRV-MSMicroSmart device driver.