Example: barber

Technical Data Sheet: F-Series Coriolis Flow and Density ...

Technical Data SheetPS-001864, Rev. DNovember 2015 Micro Motion F-Series Coriolis Flow and Density Coriolis Flow and Density MetersNovember 2015 Detailed SpecificationsF- series flow and Density accuracy optionsLiquid mass flow accuracyGas mass flow accuracyDensity accuracy (g/cm3) F050 F100 F200 F300 Note:High temperature and high pressure models (base model codes A, B, and P, for example, F050A) are not capable of enhanced Density accuracy of Detailed Specifications .. 2 Process Pressure Ratings .. 4 Temperature and Pressure De-Ratings .. 5 Hazardous area classifications .. 13 Process connections .. 15 Flow tube informationModelNumber of tubesTube inside diameter inchesTube inside diameter mmTube lengthinchesTube specification flange compatibilityModel1/2 3/4 1 1-1/2 2 3 4 F025 F050 F100 F200 F300 2015F- series Coriolis Flow and Density MetersDIN specification flange compatibilityModelDN15DN25DN40DN50DN80DN 100F025 F050 F100 F200 F300 EN1092-1 specification flange compatibilityModelDN15DN25DN40DN50DN80DN 100F025 F050 F100 F200 F300 JIS B 2220(1) specification flange compatibility(1)Sensors with JIS process connections do not meet ASME power piping F050 F100 F200 F300 VCO/VCR specification flange compatibility and Tri-clamp compatible flanges ModelVCO specificationTri-clamp compatible#4#

Technical Data Sheet PS-001864, Rev. D November 2015 Micro Motion® F-Series Coriolis Flow and Density Meters

Tags:

  Series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Technical Data Sheet: F-Series Coriolis Flow and Density ...

1 Technical Data SheetPS-001864, Rev. DNovember 2015 Micro Motion F-Series Coriolis Flow and Density Coriolis Flow and Density MetersNovember 2015 Detailed SpecificationsF- series flow and Density accuracy optionsLiquid mass flow accuracyGas mass flow accuracyDensity accuracy (g/cm3) F050 F100 F200 F300 Note:High temperature and high pressure models (base model codes A, B, and P, for example, F050A) are not capable of enhanced Density accuracy of Detailed Specifications .. 2 Process Pressure Ratings .. 4 Temperature and Pressure De-Ratings .. 5 Hazardous area classifications .. 13 Process connections .. 15 Flow tube informationModelNumber of tubesTube inside diameter inchesTube inside diameter mmTube lengthinchesTube specification flange compatibilityModel1/2 3/4 1 1-1/2 2 3 4 F025 F050 F100 F200 F300 2015F- series Coriolis Flow and Density MetersDIN specification flange compatibilityModelDN15DN25DN40DN50DN80DN 100F025 F050 F100 F200 F300 EN1092-1 specification flange compatibilityModelDN15DN25DN40DN50DN80DN 100F025 F050 F100 F200 F300 JIS B 2220(1) specification flange compatibility(1)

2 Sensors with JIS process connections do not meet ASME power piping F050 F100 F200 F300 VCO/VCR specification flange compatibility and Tri-clamp compatible flanges ModelVCO specificationTri-clamp compatible#4#8#12#161/2 3/4 1 1-1/2 2 3 F025 F050 F100 F200 F300 Coriolis Flow and Density MetersNovember 2015 Process Pressure RatingsSensor maximum working pressure reflects the highest possible pressure rating for a given sensor. Process connection type and environmental and process fluid temperatures may reduce the maximum rating. See Temperature and Pressure De-Ratings on page 5 for common sensor and fitting sensors comply with ASME power piping code, ASME process piping code, and Council Directive 97/23/EC of 29 May 1997 on pressure NE132 compliant flangesModelDN15DN25DN50DN80DN100F025 F050 F100 F200 F300 Transmitter compatibilitySensor modelTransmitter model or series1500/25001700/27002200S2400S3000 seriesFMTAll F-Series models NoteF- series sensors with JIS process connections do not comply with ASME power piping (1)(1)Higher pressure ratings may be available.

3 Contact factory for further working pressurepsigbargF025S/A, F050S/A, F100S/A, F200S, F300S 1,450100F025H/B, F050H/B, F100H/B, F200H, F300H2,160149F025P2,320160F050P5,800400F 100P6, 2015F- series Coriolis Flow and Density MetersTemperature and Pressure De-RatingsF025S F300S ASME F316/F316 LCL1500: F025S F200S ASME F316/F316 LNotes: The ratings in this section apply to the combined sensor and process connection to ensure that the meter does not exceed the limits of either component. The temperature and pressure de-ratings graphs do not represent all possible model and fitting combinations. For combinations not listed here, contact a sales representative or the 013634006008001000120014001600 Pressure (psi)CL900CL300CL60027527523521519502004 00-200-1000100200300400 Temperature ( F)CL150145014501450150015001500150014101 4501450145014501600160015041450150015501 6001650 Pressure (psi)F200SF050SF025 & F100S13631410136313501400-200-1000100200 300400 Temperature ( F) Coriolis Flow and Density MetersNovember 2015F025H F300H ASME F304/F304 LCL900/1500.

4 F025H F200H ASME F304/F304L720720600540495144014401200107 5995216021601800161514901000150020002500 Pressure (psi)CL900CL600CL30027527523020519049505 00-200-1000100200300400 Temperature ( F)CL150360036003000269024852683268326832 645285024852600280030003200340036003800 Pressure (psi)F200HF025HF050H26832683268326452400 2400240023662283200022002400-200-1000100 200300400 Temperature ( F) 2015F- series Coriolis Flow and Density MetersF025A F100A ASME F316/F316LF025B F100B ASME F304/F304L720620560515480450439144012401 1201025955900881136312851216118560080010 00120014001600 Pressure (psi)CL600CL300CL900/1500275235215195170 1401210200400-1000100200300400500600700 Temperature ( F)CL150720600540495465440428144012001075 9959308858606008001000120014001600 Pressure (psi)CL600CL3002752302051901701401210200 400-1000100200300400500600700 Temperature ( F) Coriolis Flow and Density MetersNovember 2015CL900/1500 F025B F100B - ASME F304/F304 LDIN 2635, 2637, 2638 F316/F316L360030002485233022102148268326 45240024002500300035004000 Pressure (psi)F025BF050BF100B24002400236622832224 218215002000-1000100200300400500600700 Temperature ( F)F100B404040363410091849411011010440608 0100120 Pressure (Bar)PN160: F200 SPN100/160: F025S-F100 SPN100: F300 SPN40: F025S-F300S020-150-5050150250 Temperature ( C) 2015F- series Coriolis Flow and Density MetersEN 1092-1 F316/F316L and F304/304 LEN 1092-1 F316/F316L and F304/F304L100100100918439393431284060801 00120 Pressure (Bar)PN100PN40020-150-5050150250 Temperature ( C)40404036343230291001001009184807471406 080100120 Pressure (Bar)PN100.

5 F025A-F100 APN40, F025A-F100A3939343128262423020-100010020 0300400 Temperature ( C)PN40, Coriolis Flow and Density MetersNovember 2015 JIS B 2220 F316/316L and F304/304 LJIS B 2220 F316/F316L and F304F/304L High temperatureNote:Sensors with JIS process connections do not comply with ASME power piping (Bar)40K20K14141413121414131201020-150-5 050150250 Temperature ( C)10K34343433323029686868666360573040506 07080 Pressure (Bar)40K: F025A-F100A20K, F025A-F100A14141413121110302901020-10001 00200300400 Temperature ( C)10K, 2015F- series Coriolis Flow and Density MetersTri-Clamp compatible 316L and N06022 VCO/VCR 316/316L and 3-inch grooved coupling 316L145014501450145013631500150015001479 1427110012001300140015001600 Pressure (psi)F025H-F100HF025S-F100SF200S-F300S, F200H-F300H1000100010009869518009001000- 200-1000100200300400 Temperature ( F)F200SF300S, F200HF300H145014501450145013631500150015 00150014109001100130015001700 Pressure (psi)F050SF025S,F100S7507507507507015007 00-200-1000100200300400 Temperature ( F)3-INCH*5229(' &283/,1* Coriolis Flow and Density MetersNovember 2015 VCO and VCR 316/316L High pressure23202320218137003700357143004300 4150460046004439200025003000350040004500 5000 Pressure (psi)VCO, F050P, #12 VCR, F050P #8 VCO/VCR, F025 PVCR, F050P #12218150010001500-200-1000100200300400 Temperature ( F))

6 , 2015F- series Coriolis Flow and Density MetersHazardous area classifications Detailed classifications(1) CSA and CSA C-USModels F025, F050, F100, and F200 with junction boxAmbient temperature: +140 F max. (+60 C max.)Class I, Div. 1, Groups C and DClass I, Div. 2, Groups A, B, C, and DClass II, Div. 1, Groups E, F, and GAll models with Model 2400S transmitterAmbient temperature: 40 to +140 F ( 40 to +60 C)Class I, Div. 2, Groups A, B, C, and DClass II, Div. 2, Groups F and GModels F025, F050, F100, and F200 with core processor, Model 2200S, or Model 1700/2700 transmitterAmbient temperature: 40 to +140 F ( 40 to +60 C)Class I, Div. 1, Groups C and DClass I, Div. 2, Groups A, B, C, and DClass II, Div. 1, Groups E, F, and GModels F300S and F300H with junction boxAmbient temperature: +140 F max. (+60 C max.)Class I, Div. 1, Groups C and DClass I, Div. 2, Groups A, B, C, and DClass II, Div. 1, Groups E, F, and GModels F300S and F300H with core processor, Model 2200S, or Model 1700/2700 transmitterAmbient temperature: 40 to +140 F ( 40 to +60 C)Class I, Div.

7 1, Groups C and DClass I, Div. 2, Groups A, B, C, and DClass II, Div. 1, Groups E, F, and GAll high-temperature models with junction boxAmbient temperature: +140 F max. (+60 C max.)Class I, Div. 1, Groups C and DClass I, Div. 2, Groups A, B, C, and DClass II, Div. 1, Groups E, F, and GULM odels F025, F050, F100, and F200 with junction boxAmbient temperature: 4 to +104 F ( 20 to +40 C)Class I, Div. 1, Groups C and DClass I, Div. 2, Groups A, B, C, and DClass II, Div. 1, Groups E, F, and GIECExModels F025, F050, F100, F200 with core processor or Model 1700/2700 transmitter Ex ib IIC T1 T5 Models F025, F050, F100, F200 with Model 1700/2700 transmitter with THUM adapterEx ib IIC T1 T4 Models F025, F050, F100 and F200 with junction boxEx ib IIC T1 T6 Model F300S and F300H with core processor or Model 1700/2700 transmitter Ex ib IIB T1 T5 Model F300S and F300H with Model 1700/2700 transmitter with THUM adapterEx ib IIB T1 T4 Models F300S and F300H with junction boxEx ib IIB T1 T6 Models F025, F050, F100, F200 with Model 2200S transmitter Ex ib IIC T1 T4 Model F300S and F300H with Model 2200S transmitterEx ib IIB T1 Coriolis Flow and Density MetersNovember 2015 NEPSIAll models with Model 2400S transmitterEx nA II T1 T5 Models F025, F050, F100, F200 with core processor or Model 1700/2700 transmitter Ex ib IIC T1 T5 Models F025, F050.

8 F100 and F200 with junction boxEx ib IIC T1 T6 Model F300S and F300H with core processor or Model 1700/2700 transmitter Ex ib IIB T1 T5 Models F300S and F300H with junction boxEx ib IIB T1 T6 ATEXAll models with Model 2400S transmitter II 3G Ex nA IIC T1 T5 GcII 3D Ex tc IIIC T(1) C Dc IP66 Models F025, F050, F100, and F200 with integral core processor or Model 1700/2700 transmitterMax. ambient for core processor is +60 CTransmitter with THUM adapter and display 0575 II 3G Ex nA IIC T1 T5 GcTransmitter with THUM adapter, without display 0575 II 2G Ex ib IIC T1 T4 Transmitter with display 0575 II 2G Ex ib IIB+H2 T1 T5II 2D Ex tD A21 IP65 T(2) CCore processor or transmitter without display 0575 II 2G Ex ib IIC T1 T5II 2D Ex tD A21 IP65 T(2) CModels F025, F050, F100, and F200 with junction box when connected to MVD transmitter 0575 I 2G Ex ib IIC T1 T6II 2D Ex tD A21 IP65 T(2) CModels F025, F050, F100, and F200 with Model 2200S transmitter:(3) 0575 II 2G Ex ib IIC T1 T4II 2D Ex ibD 21 T(2) CModel F300 with integral core processor or Model 1700/2700 transmitter (max.)

9 Ambient for core processor is +60 C)(3) 0575 II 2G Ex ib IIB T1 T5II 2D Ex tD A21 IP65 T(2) CModel F300 with junction box connected to MVD transmitter 0575 II 2G Ex ib IIB T1 T6II 2D Ex tD A21 IP65 T(2) CModel F300 with Model 2200S transmitter(3) 0575 II 2G Ex ib IIB T1 T4II 2D Ex ibD 21 T(2) C(1)All information and approvals may change depending on sensor/transmitter configurations and operating conditions. Please reference appropriate certificates for exact approvals.(2)For ambient and process temperature limits, refer to the appropriate approval certificate.(3)For transmitter with THUM adapter, the ATEX approval is 0575 II 2G Ex ib IIB T1 classifications(1) (Continued) 2015F- series Coriolis Flow and Density MetersProcess connectionsDimensions with process connectionsDimension A is provided for each process fitting type, when available. It is the finished face-to-face dimension of the sensor with the process connection 1/8 inch ( 3 mm).

10 Weight with process connectionsProduct weights in this section include the weight of the sensor with the process connection and integral core processor, except where noted. Values are rounded to 1 lb ( kg). Contact the factory for product shipping fitting optionsNote:The tables in this section do not represent all possible model and flange combinations. For combinations not listed here, contact a sales representative or the F025S CodeDescriptionDim Ainch (mm)Weightlb (kg)1131/2-inchCL150 ASME neck flangeRaised (406)14 ( )1141/2-inchCL300 ASME neck flangeRaised (416)15 (7)1151/2-inchCL600 ASME neck flangeRaised (428)16 (7)116DN15PN40 DIN 2635F316/F316 LWeld neck flangeForm C (387)15 (7)120DN15PN100/160 DIN 2638F316/F316 LWeld neck flangeForm E (401)17 (8)1211/2-inchTri-Clamp compatible316 LHygienic (355)12 ( )Dim. Coriolis Flow and Density MetersNovember 201512215mm20 KJIS B 2220F316/316 LWeld neck flangeRaised (392)15 (7)170DN15PN100/160 EN 1092-1F316/F316 LWeld neck flangeType (391)17 (8)172DN25PN40EN 1092-1F316/F316 LWeld neck flangeType (387)17 (8)176DN15PN40EN 1092-1F316/F316 LWeld neck flangeType (401)15 (7)178DN15PN100EN 1092-1F316/F316 LWeld neck flangeType (391)17 ( )183DN25PN40EN 1092-1F316/F316 LWeld neck flangeType (353)17 (8)22115mm40 KJIS B 2220F316/316 LWeld neck flangeRaised (419)19 (9)222DN15 DIN11851316/316 LHygienic (387)12 ( )310DN15PN40EN 1092-1F316/F316 LWeld neck flangeType (355)15 (7)319#8 VCO316/316 LSwagelok compatible fitting1/2-inch NPT female (401)(1)12 ( )(1) Dimension specified in table does NOT include fitting length.