Transcription of TECHNICAL GUIDE - UPGNET
1 445348-YTG-E-0513 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALETECHNICAL GUIDE80% SINGLE STAGE ECMRESIDENTIAL GAS FURNACESMULTI-POSITIONSTANDARD & LOW NOx MODELS: TM8X, TMLXNATURAL GAS60 - 120 MBH INPUTDue to continuous product improvement, specifications are subject to change without us on the web at rating information can be found at limited warranty on the heat heat exchanger warranty on commercial 5-year limited Parts 10-year limited parts warranty when product isregistered online within 90 days of purchase for replace-ment or closing for new home These compact units employ induced combustion, reliable hotsurface ignition and high heat transfer aluminized tubular heatexchangers. The units are factory shipped for installation inupflow or horizontal applications and may be converted fordownflow furnaces are designed for residential installation in abasement, closet, alcove, attic, recreation room or garage andare also ideal for commercial applications.
2 All units are factoryassembled, wired and tested to assure safe dependable andeconomical installation and units are Category I listed and may be common ventedwith another gas appliance as allowed by the National Fuel Easily applied in upflow, horizontal left or right, or downflowinstallation with minimal conversion necessary. Compact, easy to install, ideal height 33" tall cabinet. Blower-off delay for cooling SEER improvement. Easy access to controls to connect power/control wiring. Built-in, high level self diagnostics with fault code displaysstandard on integrated control module for reliable operation. Low unit amp requirement for easy replacement application. All models are convertable to use propane (LP) gas. Electronic Hot Surface Ignition saves fuel cost with increaseddependability and reliability.
3 100% shut off main gas valve for extra safety. 5 speed direct drive, X13 style high efficiency DC motor. 24V, 40 VA control transformer and blower relay supplied foradd-on cooling. Hi-tech tubular aluminized steel primary heat exchanger. Timed on, adjustable off blower capability for maximumcomfort. Blower door safety switch. Solid removable bottom panel allows easy conversion. Low NOx models have been designed to meet specific coderequirements. Airflow leakage less than 1% of total airflow at ductblasterconditions. No knockouts to deal with, making installation easier. Movable duct connector flanges for application flexibility. Quiet inducer operation. Inducer rotates for easy conversion of venting options. Fully supported blower assembly for easy access andremoval of blower.
4 External air filters used for maximum flexibility in meetingcustomers IAQ needs. Venting applications - may be installed as a common ventwith other gas-fired appliances or use a masonry chimney. 1/4 turn knobs provided for easy door removal. High-efficiency blower motor for lower electrical power usageand improved A/C SEER ratings. Insulated blower compartment for thermal and Controls Unitary ProductsNominal external static pressure is at furnace outlet ahead of cooling Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local SIDEWALL VENTINGFor applications where vertical venting is not possible, the onlyapproved method of horizontal venting is the use of an auxiliarypower vent.
5 Auxiliary power venters must be approved by CSA,UL, or other recognized safety agencies. Follow all applicationand installation details provided by the manufacturer of thepower PERFORMANCEThe airflow capacity data published in the Blower Perfor-mance table shown represents blower performance applications of these furnaces require the use of fieldinstalled air filters. All filter media and mounting hardware orprovisions must be field installed external to the furnace cabi-net. DO NOT attempt to install any filters inside the SIDERIGHT .5 RETURN ElectricalEntryGas PipeEntryThermostatWiringFRONT14 1 23 SUPPLY 20 .5 BGas PipeEntryThermostatWiring33 ElectricalEntryVent ConnectionOutletVentConnectionOutlet4 DiameterOutletVent ConnectionCabinet and Duct DimensionsModelsNominalCFM (m3/min)CabinetSizeCabinet Dimensions (Inches)ApproximateOperating WeightsABC LbsTM(8,L)X060A12MP111200A14 1/213 3 (8,L)X080B12MP111200B17 1/216 3 (8,L)X080C16MP111600C2119 7 (8,L)X100C16MP111600C2119 7 (8,L)X100C20MP112000C2119 7 (8,L)X120C20MP112000C2119 7 & Physical / Electrical DataModelsInput OutputAFUEAir Temp.
6 RiseMax. OutletAir TempBlowerBlower SizeMax Over-Current ProtectTotal UnitAmpsMin. wire Size (awg) @ 75 ft one wayMBHMBH F FHPAmpsTM(8,L) x (8,L) x (8,L) x (8,L) x (8,L) x (8,L) x Controls Unitary Products31. Air velocity through throwaway type filters may not exceed 300 feet per min-ute ( m/min). All velocities over this require the use of high velocity Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 (LP) Conversion Kit - This accessory conversion kitmay be used to convert natural gas units for propane (LP) - All Models Side Return Filter Racks - 1SR0200 - All Models1SR0302 - All ModelsBottom Return Filter Racks - 1BR05xx series are galvanizedsteel filter racks.
7 1BR06xx are pre-painted steel filter racks tomatch the appearance of the furnace or 1BR0614 - For 14-1/2 cabinets1BR0517 or 1BR0617 - For 17-1/2 cabinets1BR0521 or 1BR0621 - For 21 cabinetsMasonry Chimney Kits - For installations where these fur-naces are vented using existing or new lined masonry Floor Base Kit - For installation of these fur-naces in downflow applications directly onto combustible floor-ing material. These kits are required to prevent potentialoverheating situations. These kits are also required in any appli-cations where the furnace in installed in a downflow configura-tion without an evaporator coil, where the combustible floorbase kit provides access for combustible - For 14-1/2 cabinets1CB0517 - For 17-1/2 cabinets1CB0521 - For 21 cabinetsHigh Altitude Pressure Switches - For installation where thealtitude is less than 5,000 feet it is not required that the pres-sure switch be changed.
8 For altitudes above 5,000 feet, see 060, 080, 1201PS3302 100 Thermostats - Compatible thermostat controls are availablethrough accessory sourcing. For optimum performance andinstallation, refer to the UPGNET Low Voltage Wiring Diagram document to select and apply side return above 1800 CFM is approved as long asthe filter velocity does not exceed filter manufacturer s rec-ommendation and a transition is used to allow use on a20x25 Filter SizesCFMC abinetSizeSide(in)Bottom(in)1200A16 x 2514 x 251200B16 x 2516 x 251600C16 x 2520 x 252000C(2) 16 x 2520 x 25 Unit Clearances to Combustibles (All dimensions in inches, and all surfaces identified with the unit in an upflow configuration)ApplicationTopFrontRearLef t SideRight SideFlueFloor/BottomClosetAlcoveAtticLin e ContactUpflow160036 CombustibleYesYesYesNoUpflow B-Vent130001 CombustibleYesYesYesNoDownflow160036111.
9 Special floor base or air conditioning coil required for use on combustible sYe sYe sN oDownflow B-Vent13000111Ye sYe sYe sN oHorizontal160036 CombustibleNoYesYesYe s22. Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and build-ing joists, studs or B-Vent130001 CombustibleNoYesYesYe s2 Subject to change without notice. Published in 2013 by Johnson Controls, Inc. All rights : 445348-YTG-D-0612 York International York DriveNorman, OK 73069 NOTES:1. Airflow expressed in standard cubic feet per minute (SCFM).2. Motor voltage at 115 Performance CFM - Any Position (without filter)ModelsSpeedAirflow Data (SCFM)1, 2 Ext. Static Pressure (in. H2O) (8,L)X060A12MP11 High126012201180115011101070103099094090 0 Medium High1160112010801030990950900850800760 Medium1010960920880830780740680640590 Medium Low860810770710670580560510460410 Low800760710650610550500460390350TM(8,L) X080B12MP11 High133013001270124012101160113010901050 1000 Medium High1140110010701020990950900850800760 Medium990960920870830780730680630580 Medium Low920890840790740700640600550510 Low820770730680630580540480430390TM(8,L) X080C16MP11 High173017001660161015801520147014101360 1300 Medium High156015301490145014001350131012701220 1170 Medium1370133012801230118011301080103097 0910 Medium Low1190114010901040990930870820750680 Low1000940880820750680600540460410TM(8,L )
10 X100C16MP11 High173016901650161015701530147014201360 1310 Medium High157015301490144014001360132012701220 1170 Medium1360131012601220118011301070101095 0890 Medium Low12101160111010501000940880810760700 Low1010950900820760680610540500430TM(8,L )X100C20MP11 High223021802130207020201960190018501790 1720 Medium High182017801740168016201580153014701410 1350 Medium1610155015001440139013401280123011 701110 Medium Low1440138013201270121011501090103096089 0 Low1210115010801020960890820740680640TM( 8,L)X120C20MP11 High215020202040199019301880182017701720 1660 Medium High178017401690164015901540149014301380 1310 Medium1580152014701420137013201270122011 601090 Medium Low1410135012901240118011301070102095089 0 Low1190113010601000940880820760680630