Technical Manual - CSR Hebel
Use of Technical Manual for Hebel AAC Block Structures In New Zealand, AAC block structures require specific engineering design. Such design must be undertaken by a suitably qualified structural engineer. Furthermore, specification of control joint requirements and locations in Hebel AAC block structures must be assessed and verified by the
Tags:
Manual, Design, Specification, Technical, Structure, Technical manual
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Design & Installation Guide - hebel.com.au
hebel.com.auHebel® PowerBlock™ Design and Installation Guide 2 It is the responsibility of the architectural designer and engineering parties to ensure that the details in the Hebel®® PowerBlock™ Design and Installation Guide are
HEBEL PRODUCT GUIDE
hebel.com.auHebel is the name of the autoclaved aerated concrete (AAC) ... and cement – are mixed with an expansion agent to form a semi-liquid mix called slurry ... you can be assured you’re getting high quality products and systems and unmatched technical expertise with Hebel.
Technical Manual - Home - CSR Hebel
hebel.com.au• Control joints (C.J.), (one type is an expansion joint), are provided to relieve the induced stresses resulting from thermal expansion or contraction of the AAC, or differential movement between the AAC and another material or structure, ...
Houses, Low Rise Multi-Residential and Commercial 75mm ...
hebel.com.aumulti-residential, commercial and industrial construction. The floor applications consist of a Hebel PowerFloor panel connected to a steel or timber joist system forming a platform floor. Fig 1.1.1 Residential Fig 1.1.2 Residential Suspended Ground Floors Suspended First Floors Fig 1.1.3 Commercial Floors - schools, offices and community centres
Applications, Commercial, Residential, Commercial and residential
Technical Manual - CSR Hebel
hebel.com.auITW Buildex Ph: 1300 368 101 Fax: 1800 456 448 4 Ash Road Hoxton Park NSW 2171 www.buildex.com.au Victoria Powers Fasteners Ph: (03) 8787 5888 03) 8787 5899 Dandenong South VIC 3175 www.powers.com.au TOX Fasteners Ph: (03) 9338 3996 Fax: (03) 9338 8366 47 Allied Drive Tullamarine VIC 3043 CSR Hebel Distributors Contact Details
Related documents
Chapter 2 Loads for designing foundations
site.iugaza.edu.psexcept some unusual buildings and structures. ... In the specification of the American Standards Association , wind loads are given for various heights of the structures ( up to 360 meters ) ... in foundation design in countries where seismic shocks are probable .
IS 807 (2006): Design, erection and testing (structural ...
law.resource.org8.2 Seismic Load 8.3 Amplification of Load - 8.4 Case of Loading (Combination of Loads) ... design of structures (fourth revision ) Specification for hot forged steel rivetsfor hot closing ( 12to 36 mm diameter ) (first revision) 2062:1999 Steel for general structural purposes — Specification (Jjih revision ) 2155:1982 Specification for cold ...
Gusset Plate Stress 7a - ARC Structural
arcstructural.comConnection Design for Steel Structures Chapter 7a, Page 1 of 21 ... Gusset plates are used in steel buildings to connect bracing members to other structural members in the lateral force resisting system. ... calculation if interface loads, and seismic design will be presented in future papers in this series. ...
Design, Seismic, Plate, Building, Structure, Seismic design, Guesst, Gusset plate
API Recommended Practice 2A-WSD
www.api.orgof the AISC Specification for Structural Steel Buildings— Allowable Stress Design and Plastic Design. The use of later editions of AISC specifications is specifically not recommended for design of offshore platforms. The load and resistance factors in these specifications are based on calibration with building design practices and may not
Structural Use of Unreinforced Masonry
www.iitk.ac.inc) Eurocode 6, Design of Masonry Structures – Part 1-1: General rules for buildings – Rules for Reinforced and Unreinforced Masonry, European Committee for Standardization. d) NZS 4230 Part 1 & 2: 1990, Code of Practice for the Design of Concrete Masonry Structures and Commentary, Standards Association of New Zealand.
Design, Building, Structure, Structural, Masonry, For building, Structural use of unreinforced masonry, Unreinforced
GENERAL STRUCTURAL NOTES Affiliated Engineers
www.mallenconstruction.comb. specifications for masonry structures (aci 530.1-05/asce 6-05/tms 602-05). 7. steel deck: a. north american specification for the design of cold formed steel structural members, including 2004 supplement (nas-01). b. sdi design manual for composite decks, form decks and roof decks. 8. cold formed metal framing:
KINETICS™ Guide to Understanding IBC Seismic for MEP
kineticsnoise.comD2.1 – 4.2 Exemptions for Seismic Design Categories A and B D2.1 – 4.3 Exemptions for Seismic Design Category C D2.1 – 4.4 Exemptions for Seismic Design Categories D, E, and F D2.1 – 4.5 “Chandelier” Exemption D2.1 – 4.6 Component Size Relative to the Building Structure D2.1 – 4.7 Reference Documents
Technical Document Seismic Technical Guide
www.usg.comTechnical Seismic Technical Guide Document Hanger Wire Attachment Code Requirements 1 The International Building Code (IBC) defines the requirement for hanger wire and their supports and attachment methods. However, there are exceptions and the application of hanger wires in a seismic design category can meet code requirements in different ways.
DIVISION 1 - GENERAL REQUIREMENTS
cpm.umn.eduto be performed adjacent to or in the immediate vicinity of existing structures, contact the owner’s representative to determine if the building surveys and seismic monitoring are required. 2.2. Records of the pre-construction survey shall note pre -construction defects, measurements, elevations and newly discovered defects or changes.
Design for Fatigue of Structural Steel
www.cscos.comDesign life of 25 years, crane is heavily loaded 3x per day x 5 days a week = 19,500 cycles (fatigue check . not technically . required, < 20,000 cyles) Design life of 50 years, crane is heavily loaded 15x per shift x 2 shifts x 5 days a week = 390,000 cycles (fatigue check . required!!)