Example: confidence

TECHNICAL MANUAL OPERATOR'S, UNIT, AND …

TM 10-4930-236-13&PTECHNICAL MANUALOPERATOR'S, unit , ANDDIRECT SUPPORT maintenance MANUALAND REPAIR PARTS AND SPECIAL TOOLS LISTThis copy is a reprint which includes currentpages from Changes 1 through 2-1 - operator PREVENTIVEMAINTENANCE CHECKSAND SERVICESPAGE 2-5 operator MAINTENANCEINSTRUCTIONSPAGE 3-1 unit MAINTENANCEINSTRUCTIONSPAGE 4-1 unit TROUBLESHOOTINGPAGE 4-10 DIRECTSUPPORT MAINTENANCEINSTRUCTIONSPAGE 5-1 DIRECT SUPPORTTROUBLESHOOTING IPAGE 5-1 ALPHABETICAL INDEXPAGE INDEX-1 Approved for public release; distribution is , DEPARTMENT OF THE ARMY30 AUGUST 1991 TANK AND PUMP UNIT, LIQUID DISPENSING;FOR TRUCK MOUNTINGMIL DESIGN TANK AND PUMP UNITELECTRIC MOTOR DRIVENMODEL (97403) 13226E2150 NSN 4930-01-274-0212TM 10-4930-236-13&PC2 CHANGEHEADQUARTERSDEPARTMENT OF THE ARMYWASHINGTON.

TM 10-4930-236-13&P TECHNICAL MANUAL OPERATOR'S, UNIT, AND DIRECT SUPPORT MAINTENANCE MANUAL AND REPAIR PARTS AND SPECIAL TOOLS LIST This copy is a reprint which includes current

Tags:

  Manual, Maintenance, Technical, Operator, Unit, Part, Technical manual operator s, Maintenance manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TECHNICAL MANUAL OPERATOR'S, UNIT, AND …

1 TM 10-4930-236-13&PTECHNICAL MANUALOPERATOR'S, unit , ANDDIRECT SUPPORT maintenance MANUALAND REPAIR PARTS AND SPECIAL TOOLS LISTThis copy is a reprint which includes currentpages from Changes 1 through 2-1 - operator PREVENTIVEMAINTENANCE CHECKSAND SERVICESPAGE 2-5 operator MAINTENANCEINSTRUCTIONSPAGE 3-1 unit MAINTENANCEINSTRUCTIONSPAGE 4-1 unit TROUBLESHOOTINGPAGE 4-10 DIRECTSUPPORT MAINTENANCEINSTRUCTIONSPAGE 5-1 DIRECT SUPPORTTROUBLESHOOTING IPAGE 5-1 ALPHABETICAL INDEXPAGE INDEX-1 Approved for public release; distribution is , DEPARTMENT OF THE ARMY30 AUGUST 1991 TANK AND PUMP UNIT, LIQUID DISPENSING.

2 FOR TRUCK MOUNTINGMIL DESIGN TANK AND PUMP UNITELECTRIC MOTOR DRIVENMODEL (97403) 13226E2150 NSN 4930-01-274-0212TM 10-4930-236-13&PC2 CHANGEHEADQUARTERSDEPARTMENT OF THE ARMYWASHINGTON, , 16 SEPTEMBER 'S, unit , AND DIRECT SUPPORTMAINTENANCE MANUAL ANDREPAIR PARTS AND SPECIAL TOOLS LISTTANK AND PUMP unit , LIQUID DISPENSING,FOR TRUCK MOUNTINGMIL DESIGN TANK AND PUMP UNITELECTRIC MOTOR DRIVENMODEL (97403) 13226E2150 NSN 4930 01-27440021 Approved for public release; Distribution is unlimitedTM 100930-236-13&P, 30 August 1991 is changed as and insert pages as indicated below.

3 New or changed text material is indicated by a vertical barin the margin. An illustration change is indicated by a miniature pointing pagesInsert pagesC-3 and CodC-3 and this sheet in front of MANUAL for reference Order of the Secretary of the Army:GORDON R. SULLIVANG eneral, United States ArmyOfficial:Chief of StaffMILTON H. HAMILTONA dministrative Assistant to theSecretary of the Army02444 DISTRIBUTION:To be distributed in accordance with DA Form 12-25-E, block 5291, operator , unit and Direct SupportMaintenance requirements for TM 10-4930-236-13& 10-4930-236-13&PC1 CHANGEHEADQUARTERSDEPARTMENT OF THE , , 27 APRIL 1992 operator 'S, unit , AND DIRECT SUPPORTMAINTENANCE MANUAL ANDREPAIR PARTS AND SPECIAL TOOLS LISTTANK AND PUMP unit , LIQUID DISPENSING,FOR TRUCK MOUNTINGMIL DESIGN TANK AND PUMP UNITELECTRIC MOTOR DRIVENMODEL (97403) 13226E2150 NSN 4930-01-274-0021 Approved for public release.

4 Distribution is unlimitedTM 100930-236-13&P, 30 August 1991 is changed as and insert pages as indicated below. New or changed text material is indicated by a vertical barin the margin. An illustration change is indicated by a miniature pointing hand. Appendix F. unit and DirectSupport maintenance Repair Parts and Special Tools List (RPSTL), has been revised in its entirety, therefore,no change bars/hands are pagesInsert pagesi through iii/(iv blank)i through iii/(iv blank)F-1 through F-7/(F-8 blank)F-1 through this sheet in front of MANUAL for reference Order of the Secretary of the Army:GORDON R.

5 SULLIVANG eneral, United States ArmyOfficial:Chief of StaffMILTON H. HAMILTONA dministrative Assistant to theSecretary of the Army01184 DISTRIBUTION:To be distributed in accordance with DA Form 12-25E, (qty rqr block nos. 1726, 1727 and 1728).TM 10-4930-236-13&PWARNINGSGive particular attention to specific WARNINGS and CAUTIONS throughout this MANUAL . DEATH or seriousInjury may result It personnel tall to observe safety cleaning solvent, PD-680A, used to clean parts Is potentially dangerous to personnel and property.

6 Avoidrepeated or prolonged skin contact. Do not use near open flame or excessive heat. Flash point of solvent Is100 -138 F (38 - 60 C).Do not smoke or use open name within 50 feet ( meters) of tank and pump sure fire extinguishers and fire fighting equipment are available In the immediate area. Be extremelycareful when using fire extinguisher In an enclosed area. Provide adequate not drain fuel from the unit on the ground. Drain fuel Into a container that can be closed, otherwise a firehazard or environmental contamination could protective equipment to prevent skin and eye contact with rubber fuel resistant gloves when replacing filter elements due to toxic effects of some fuel of filter elements In accordance with local static discharge could Ignite the fuel or cause an explosion of the fuel vapor.

7 Do not operate the tank andpump unit until It has been connected to suitable prevent serious Injury or death to personnel or, equipment damage, use a lifting device with a liftingcapacity of at least three tons to handle tanks or pump unit . Do not allow units to swing back and forth whilehanging In the artificial respiration, refer to FM or SERIOUS INJURY may result It personnel fall to follow Safety Precautions for welding. Prior towelding, read welding Instructions contained In Chapter 5, on repair of the Tank heat or flame to a fuel tank containing residue may result in a violent explosion, causing injury ordeath to personnel.

8 If conditions require fuel tank repairs by welding or other methods Involving heat or flame,be sure that all fumes are purged from the tank or fill tank with water before commencing the repair. It possible,tank should be filled with water prior to welding after being thoroughly purged of engaged In purging operations will not wear static electricity generating clothing. No metal buttons orfittings will be worn. All contents will be removed from tank being purged must have a static ground during all operations. Precautions should be taken with alltools and metal objects around the tank to ensure no spark will be made.

9 Conduct a combustible vapor testreading after to purging the tank using an acceptable explosive 10-930-236-13&PWARNINGSOnly personnel thoroughly instructed In the proper handling and reading of the combustion vapor tester willconduct vapor tests. Conduct a combustible vapor test reading Immediately after purging. Under nocircumstances will repair of the tank begin until declared safe by safety personnel. Discontinue all operations Itan electrical storm Is threatening or In progress. Eliminate conditions that could cause may stick to metal In cold conditions.

10 Do not touch metal parts with bare skin during cold voltage can cause Severe Shock or Death. Disconnect power cable from vehicle NATO slave receptaclebefore replacing or repairing motor or electrical components. When connecting power cable be sure RemoteON-OFF switch Is in -OFF" burns and electrical shock can result from contact with exposed electrical wires or connectors. Turn offall power switches before making electrical connections or switch In "OFF position before connecting Remote ON-OFF switch 10-4930-236-13&PHEADQUARTERST echnical ManualDEPARTMENT OF THE ARMYW ashington, DC, 30 AUGUST1991TM 10-4930-236-13&POPERATOR'S, unit , ANDDIRECT SUPPORT maintenance MANUALAND REPAIR PARTS AND SPECIAL TOOLS LISTTANK AND PUMP UNIT, LIQUID DISPENSING.