Transcription of Temposonics - atisystems.co.za
1 Temposonics Absolute, Non-Contact Position SensorsE-SeriesAnalog + Digital Pulse Outputs(Start / Stop) Temposonics ERMeasuring length 75 - 1500 mmMagnetostriction The absoluteTemposonics linearposition sensors are based on theMTS developed magnetostrictivemeasurement principle. That combi-nes various magneto-mechanicaleffects and uses the physical highprecise speed-measurement of anultrasonic wave (torsion pulse in itssensor element) for position measurement. sensor integrated sig-nal processing transforms the mea-surements directly into market stan-dard outputs. The contactless princi-ple - a movable magnet marks theposition - eliminates the wear, noiseand erroneous signal problems andguarantees the best durability withoutany factorTemposonics ERlinear displace-ment transducers are precise, dura-ble and cost effective alternatives tolinear potentiometers.
2 The innovativeconcept of Temposonics ER transdu-cers, combined with solid enginee-ring and extremely rugged construc-tion, provides proven reliability in thetoughest industrial ER models offer solu-tions to wear problems associatedwith linear your position sensing requi-rements are simple or complex, Temposonics ER transducers willprovide a solution in his form factorand mounting configuration that fitsto your application. Linear, absolute Measurement Contactless Sensing with highest Durability Rigged Industrial sensor , EMC shielded and CE certified Linearity Tolerance better 0,02 % Repeatability 0,001 %- Analog (V/mA)- Start / Stop + sensor -Parameter Upload Measuring Range 75 - 1500 mmRod and Piston SensorI 2 ITemposonics-ERAnalog Start / StopMTS Sensors Technical DataInputMeasured variable DisplacementMeasuring range75 - 1500 mmOutput1.
3 Voltage0 - 10 VDC and 10 - 0 VDC (Controller input resistance RL> 5 kOhm)2. Current4 - 20 mA or 20 - 4(0) mA (Min/max. load: 0/500 Ohm)3. Start / StopRS-422 differential signal, additional, available: Serialparameter upload of Measuring range, Offset, Gradient(Ultrasonic speed of sensing pulse), status and manufacturer numberAccuracyResolution- Analog: Infinite- Start / Stop: 0,1 / 0,01 / 0,005 mm (Controller dependent)Linearity, uncorrected< 0,02 % (Minimum 60 m)Repeatability< 0,001 % frequencyAnalog: > 1,5 kHz / Digital: controller dependentRipple< 0,01 % / Digital: controller dependentOperating conditionsMagnet speedAnyOperating temperature-40 C.
4 +75 C Dew point, humidity90% rel. humidity, no consationIngress protectionIP65 if mating cable connector is correctly fittedSchock test100 g (single hit) IEC-Standard 68-2-27 Vibration rating10 g / 10 - 2000 Hz nach IEC-Standard 68-2-6 Standards, EMC testElectromagnetic emission EN 50081-1 Electromagnetic susceptibility EN 50082-2EN 61000-4-2/3/4/6, Level 3/4, Criteria A, CE qualifiedForm factor, materialSensor housingAluminumRodStainless Steel Type 303 / positionAny orientationMounting typeAdjustable mounting feet or rod endsElectrical ConnectionConnection type6 pin. Connector M16 Input voltage24 VDC (-15 / +20 %)- Polarity protectionup to -30 VDC- Overvoltage protectionup to 36 VDCC urrent consumtion50 - 140 mA (Digital 50 - 100 mA), stroke length dependentRipple< 1 % peak to peakElectric strength500 VDC (DC ground to machine ground)Linearity protocolSensor Temposonics -ER, Measuring range 1000 mmTolerance allowed: 0,2 mmTolerance measured: typical 0,12 mm, uncorrectedhousing.
5 Connection with mobile machine part is via a rod. The sensor rod isconstructed of large diameter for enhanced load-bearing, corrison resistanceand exented the rod ends the sensor can be mounted between two joints, it is possi-ble to measure the distance between two independent moving .. a rod and cylinder versionTemposonics are extremely stable sensors, ideal for continous operation underharshest industrial conditions. The sensor is completely modular in mechanicsand electronics robust aluminum cylinder profile offers flexible mounting configurations, andeasy installation. Position measurement is contactless via a permanent magnet is mounted at a stainless steel piston and moves inside the sensorI 3 ITemposonics-ERAnalog + Start / StopMTS Sensors yyyyyAnalog outputTemposonics-ER are provided with an integrated analog interface and can beconnected to a control system or indicator directly without an interface.
6 Themicroelectronics in the sensors head generates continous, strictly displacementproportional voltage and current outputs whose upscale or downscale outputaction can be selected when ordering. The output variables are is not / Stop outputDigital Temposonics -ER is equipped with a start / stop output. The sensorrequires a start signal from an external indicator in the control system andreturns a signal corresponding to the magnet position. The time elapsed bet-ween the two signals is proportional to the magnet position, to the displace-ment. Time measurement is by the indicator and used for calculating the posi-tion easy adaption to user s control systems, following sensor parameters- Measuring range- Offset- Gradient (Speed of sensing pulse)- Status- Manufacturer numbercan be read into controller without additional wiring.
7 It can be done simply byusing the standard signal type sensorsare designed for external installation on mounting options, with mounting clamps slots on three sides of thesensor, to offer a simple, yet verstaile installation process. The entire sensorcan be mounted to the machine using standard mounting clamp and screwsthat can be easily adjusted to the desired integral connector and extension cableorientation. Rod end mounting options help to simplify sensor installationdesign and facilitate articulated motion !The ER sensor is equipped with steel mounting clamp. Due to the anodic coa-ting of the profile there is no connection to the machine ground via the moun-ting feets.
8 It is necessary that you apply ground to the sensor is made with the flat pin terminal on the sensor clampM5x20 cylinder screwFastening torque max 5 NmTemposonics-ER SensorController with Start/StopInterface modul1234-++-Time intervalPositionStopStartActive sensor StrokeU/IActive sensor strokeMeasuring rangePosition magnet0sforward actingreverse actingSensor elementAll measurements in mmNecessarillyground sensorthis way! MTS Temposonics E-Series Temposonics ER 09072008e - Alterations reservedTemposonics-ERAnalog Start / StopConnector wiring1. Output: Voltage (V)PinFunction10 .. 10 V2DC Ground310 .. 0 V4DC Ground5+24 VDC (-15%+20%)6DC Ground (0V) sensor TechnologieGmbH & Co.
9 KGAuf dem Sch ffel 9D-58513 L denscheidTel.: +49-2351-9587-0 Fax: Systems CorporationSensors Division3001 Sheldon DriveCary, NC 27513, USATel.: +1-919-677-0100 Fax: Sensors Technology Aihara-cho, Machida-shiTokyo 194-0211, JapanTel.: +81-42-775-3838 Fax: connectors (Pls. order separately)6 pin female connector M16, PG7 Part No. ST C0 9131 D6 pin 90 female connector M16 Insert adjustable in 45 positionsPart No. ST C0 9131-6 Housing: Zinc, nickel platedTermination: SolderContact insert: Silver platedCable clamp: Pg 7, M16 Cable- : 6 mm (PG7), 8 mm (M16)TemposonicsRod StyleInside thread M6 Measuring range0075/0100/0150/0200/0300/0400/0500/ 0600/0750/1000/1250/1500 mmConnection typeD60- 6 pin male receptacle M16 Input voltage1- +24 VDCO utputV0- 0 - 10 V and 10 - 0 VA0- 4 - 20 mAA1- 20 - 4 mAR0- Start/StopR3- Start/Stop with sensor parameters uploadScope of Delivery:- sensor - ordered accessoriesPls.
10 Order accessories separately!Select the mounting device regardingyour application:- 1 or 2 Rod Ends M6- or / and 2 mounting clamps up to 1250 mm, 3 mounting clamps for 1500 mmMeasuring Range:See list of rangeOther length on requestMER1 AccessoriesDescriptionPart clamp400 802 Rod End M6253 3476 pin female cable connector M16ST C0 9131 D6 pin 90 female cable connector M16ST C0 9131-6 PVC cable 6x0,14 mm2K273. Output: Start / StopPinFunction1 Stop (-)2 Stop (+)3 Start (+)4 Start (-)5+24 VDC (-15%+20%)6DC Ground (0V)6 pin DIN male receptacle M16 Front face of sensor plugor rear of cable connectorM2. Output: Current (mA)PinFunction14 - 20 mA*2DC Ground320 - 4 mA*4DC Ground5+24 VDC (-15%+20%)6DC Ground (0V)*only the ordered output signal is provided.