Example: barber

THERMOCOUPLE SOURCE SERIES 22 - ALTEK …

DATA SHEET 22 Additional THERMOCOUPLE Calibrators: See Data Sheets 222A, 322 & 422 GENERAL DESCRIPTIONALTEKTHERMOCOUPLE SOURCESERIES 22 ALTEK SERIES 22 THERMOCOUPLE Sources provide22 precise temperatures for inputs to transmitters,recorders, controllers, alarms, data acquisition andcomputer systems. Model 22 provides thermocouplewire output and is cold-junction compensated forambient temperature variations. Conformity to theparticular THERMOCOUPLE vs millivolt curve is inaccordance with the latest ASTM and IPTS standards for exact temperature simulation. Linearmillivolt models are also types B, E, J, K, R, S and T areavailable in both degrees F and C. The table liststhe standard ranges. Resolution is 25, 50 or 100degrees, corresponding to full scale output of 500,1000, 1700, 2100 and 3100 degrees ranges, with an individual ON position foreach range, allow quick, easy settings for anyoutput.

DATA SHEET 22 Additional Thermocouple Calibrators: See Data Sheets 222A, 322 & 422 GENERAL DESCRIPTION ALTEK THERMOCOUPLE SOURCE SERIES 22 ALTEK SERIES 22 Thermocouple Sources provide

Tags:

  Series, Letak, Altek series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of THERMOCOUPLE SOURCE SERIES 22 - ALTEK …

1 DATA SHEET 22 Additional THERMOCOUPLE Calibrators: See Data Sheets 222A, 322 & 422 GENERAL DESCRIPTIONALTEKTHERMOCOUPLE SOURCESERIES 22 ALTEK SERIES 22 THERMOCOUPLE Sources provide22 precise temperatures for inputs to transmitters,recorders, controllers, alarms, data acquisition andcomputer systems. Model 22 provides thermocouplewire output and is cold-junction compensated forambient temperature variations. Conformity to theparticular THERMOCOUPLE vs millivolt curve is inaccordance with the latest ASTM and IPTS standards for exact temperature simulation. Linearmillivolt models are also types B, E, J, K, R, S and T areavailable in both degrees F and C. The table liststhe standard ranges. Resolution is 25, 50 or 100degrees, corresponding to full scale output of 500,1000, 1700, 2100 and 3100 degrees ranges, with an individual ON position foreach range, allow quick, easy settings for anyoutput.

2 Calibrated accuracy is of span 1degree. Negative temperatures add 2 built-in AA cells provide power for one year ofeveryday use. A front panel LED pulses every timethe Model 22 is turned on to indicate proper low cost ALTEK MODEL 22 is a complete,compact SOURCE for checkout and calibration of allthermocouple instruments in the field, shop orcontrol INSTRUCTIONSS elect the ALTEK MODEL 22 for the correctthermocouple type, the desired temperature scale (F or C), and the ALTEK THERMOCOUPLE SOURCE to the input terminals of the instrument to be tested, the field mounted head or junction box compensation and instantaneousautomatic standardization is built into the Model the temperature selection switch to the desiredtemperature and slide the ON switch to the selectedscale.

3 The Battery Check LED will pulse once indicatingproper battery voltage. If no pulse is seen, the batteriesshould be replaced with 2 AA cells. Alkaline cells are preferred for longest life and widest operatingtemperature point calibration temperatures of the instrument are then selected on the Model 22 and any requiredadjustments are made. Intermediate points may then be selected to verify instrument linearity or check critical equipment is guaranteed against defective materialand workmanship (excluding batteries) for a period ofthree years from date of shipment. Claims underguarantee can be made by returning the equipmentprepaid to our factory. The equipment will be replaced,repaired or adjusted at our option. The liability of ALTEK isrestricted to that given under our guarantee.

4 Noresponsibility is accepted for damage, loss or otherexpense incurred through sale or use of our no condition shall ALTEK be liable for any special,incidental or consequential INDUSTRIES CORPA TRANSMATION COMPANY35 Vantage Point DriveRochester, New York 14624 (716) 349-3500 Fax (716) 349-3510 Direct Temperature Output22 Precise Steps Accuracy25, 50, or 100 Degree Resolution Rugged DesignField, shop and control room use Pocket Sized1 Year Battery Life Models for Types B, E, J, K, R, S, T C & F Cold-Junction Compensated50045040035030025020015010050 047542537532527522517512575+25-251000950 9008508007507006506005505004504003503002 50200150100+500-501700165016001550150014 5014001350130012501200115011001050100095 0900850800750700650210020001900180017001 6001500140013001200110010009008007006005 0040030020010003100300029002800270026002 5002400230022002100200019001800170016001 50014001300120011001000 SPECIFICATIONSA ccuracy:Positive temperatures of span 1degree.

5 Negative temperatures of span 3 degreesCold Junction Compensation:Built-in for specifiedthermocouple typeCold Junction Temperature Effect:Within degreeat 75 F (20 C) degrees/degree change in ambientOperating Ambient Temperature:-10 to +130 F (-25 to +55 C)Ambient Temperature Effect: Zero:Included in coldjunction effectSpan: of span/degree(Unless otherwise indicated, specifications are in % of span@ 23 C) SERIES 22 STANDARD RANGES (FOR OTHER RANGES & TC TYPES CONSULT FACTORY)ORDERING INFORMATIONS torage Temperature Limits:-40 to +160 F (-40 to +70 C)Output Impedance:Fixed, 50 ohms nominalBatteries:2 AA alkaline cells provide 1 year of use atnominal 4 hours each workday. Batteries should beremoved when storing the unit >3 Indicator:LED light pulse at turn-on in eitherrangeSize:2 1/8 x 4 x 2 1/4 inches (54 x 102 x 55 mm)Weight:6 oz.

6 ( kg)Optional Carrying Case:Zippered, with belt loopSpecify THERMOCOUPLE type, scale range and F or C toinsure prompt delivery of all the above standard ranges. A22J 1000F completely describes an ALTEK 22 positionsource providing a maximum output of 1000 F for a type JthermocoupleChromel and Alumel are registered trademarks of Hoskins Manufacturing FROMBPt 30% Rh - Pt 6% RhEChromel - ConstantanJIron - ConstantanKChromel - Alumel RPt - Pt 13% RhSPt - Pt 10% RhTCopper - Constantan50010001700 Maximum2100 Scale3100 ReadingF -Degrees FahrenheitC -Degrees CelsiusOTHER PRODUCTSA ltek designs and manufactures fast, accurate instrumentsfor measurement, generation and simulation of virtuallyevery process control signal. Consult our factory directly orcontact your local stocking representative to order precise,low cost Milliamp Calibrators, Voltage Sources, DirectThermocouple Sources, RTD Simulators and FrequencySources.

7 ALTEK also produces calibrators for custom rangesand unique applications. Additional models and ranges arefrequently added to the ALTEK instrument family to meet allof your critical calibration requirements. ALTEK products aremade in the USA. April 2000 ALTEK Industries Corp Rochester, NY 14624 USA100882-900 REV: BPHONE: 1-800-322-5835 FAX: 716-349-3510E-MAIL: WEB: 22 TYPE B,R,S DEG CTYPE E,J,K,T DEG FTYPE J,K DEG FTYPE E,J,K DEG FTYPE B,R,S DEG FTYPE E,J,K,T DEG CTYPE E,J,K DEG C