Example: air traffic controller

Trace Heating Guide

TraceHeatingGuideTRACE Heating GUIDED istributor ofTrace Heating Productsfor 25 Years(Northwest) LtdTel 01978 356948(UK) LtdTel 01978 340450(Central) LtdTel 01782 274714(Liverpool) LtdTel 0151 9339022RS 21752RS 21753RS 22195RS 145174 Trace Heating Products Page 4 - 8 Tyco Trace Heating products including Raychem Isopad, Wintergard and Frostop. Systems for commercial and industrial freeze protection and process control. Also ice protection, floor warming and leak detection of Pipe ( ):Length of Pipe:Material of Pipe:Thickness & Type of Insulation:Ambient Temperature:(surrounding air, min & max)Temperature:(to be maintained, ie 5OC for frost protection)Maximum Temperature:(on the pipe ie through steam cleaning etc)Indoors OutdoorsHazardous Non-HazardousNumber of Valves:Number of Pipe Supports:Supply VoltageAdditional Information:(general description of project etc)Name:Company:Tel No:F

TRACE HE A TING PRODUCTS 5 TRACE HE A TING PRODUCTS 4 Electric Trace Heating For frost protection and temperature maintenance. WinterGard™ and Frostop For self regulating heating cable for domestic and

Tags:

  Guide, Ting, Self, Regulating, Cable, Trace, Heating, Self regulating heating cable, Trace heating guide, He a ting

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Trace Heating Guide

1 TraceHeatingGuideTRACE Heating GUIDED istributor ofTrace Heating Productsfor 25 Years(Northwest) LtdTel 01978 356948(UK) LtdTel 01978 340450(Central) LtdTel 01782 274714(Liverpool) LtdTel 0151 9339022RS 21752RS 21753RS 22195RS 145174 Trace Heating Products Page 4 - 8 Tyco Trace Heating products including Raychem Isopad, Wintergard and Frostop. Systems for commercial and industrial freeze protection and process control. Also ice protection, floor warming and leak detection of Pipe ( ):Length of Pipe:Material of Pipe:Thickness & Type of Insulation:Ambient Temperature:(surrounding air, min & max)Temperature:(to be maintained, ie 5OC for frost protection)Maximum Temperature:(on the pipe ie through steam cleaning etc)Indoors OutdoorsHazardous Non-HazardousNumber of Valves:Number of Pipe Supports:Supply VoltageAdditional Information:(general description of project etc)Name:Company:Tel No:Fax No.

2 Data Input Sheet - Fax BackFor our FREE design proposal please complete the datainput sheet below and fax it to a cable Services sales OFFICEFAX NUMBERSN orthwest LtdFax: 01978 310438UK LtdFax: 01978 311315 Central LtdFax: 01782 280547 Liverpool LtdFax: 0151 9339765 CABLESERVICES39 Industrial Trace Heating Guidelines Page 9 - 17 Page 9 General InformationPage 9 Heating cable SelectionPage 9 - 13 Heating cable InstallationPage 14 - 15 Pipe Heat Loss ChartPage 16 - 17 Heat Tracing Plastic Pipes with Chemelex Auto- Trace self - regulating Heaters18 Domestic / Commercial Trace Heating Guidelines Page 18 - 19 Page 18 Raychem WintergardPage 19 Raychem HWAT Hot Water Temperature Maintenance20 Troubleshooting Guide Page 20 - 2122 Thermostats Page 22 - 2323 Rule Of Thumb Page 23 Our History of Trace HeatingCable Services started distributing the

3 Raychem range of selfregulating Trace Heating cables in the late seventies and haveover the years acquired a wide expertise in the installation ofthe whole range of Tyco Trace Heating vast experience coupled with stocks unequalled anywhere in theUK makes cable Services the only choice for Trace Heating our experienced sales staff on the numbers listed across or use the fax back form opposite to send us details of your requirements. An immediate response is our Heating PRODUCTS5 Trace Heating PRODUCTS4 Electric Trace HeatingFor frost protection and temperature and Fr ostopFor self regulating Heating cable for domestic andcommercial freeze Services have distributed Raychem Trace Heating products for over 20 extended range of products now available from Tyco Thermal Controls includes theRaychem, Pyrotenax and Isopad products many of which are stock items at cable available include:Wintergard and Frostop Heating cables are safe and reliable.

4 self regulating technology prevents overheating and minimises energy consumption andparallel circuit configuration means cables can be cut to length on cable Services with application requirementsfor a design recommendation and quotation.(See page 3 for our simple data input sheet).HWAT PlusFor self regulating Heating for hot water temperature water temperature maintenance using HWAT Plus self regulating Trace Heating cable combinesinstant hot water in large and small buildings withimproved energy ef ficiency over traditional hot cable Service for a free design proposal HeatingFlexible, reliable and easy to install floor T2 floor Heating product range is designed to provide room Heating from floor up, Heating theroom much more evenly than traditional systems.

5 And ensuring that the floor is the warmest place in the cable Services for a free design proposal and regulating BTVE lectric Trace Heating for frost protection inindustrial applications without steam BTV family of self regulating parallel circuit Heating cables is used for frost protection of pipes and vessels. It can be used for process temperaturemaintenance up to 65OC and has an unlimited T6 rating for hazardous cable Services with application details for a design recommendation and quotation.(See page 3 for our simple data input sheet). self regulating QTVRE lectric Trace Heating for industrial process temperature maintenance applications up to 110OC, not subject to steam QTVR family of self regulating parallel circuit Heating cables is used for process temperature maintenance of pipes and vessels in industrial environments.

6 It can also be used for frost protectionon large diameter pipes and has a T4 rating for hazardous cable Services with application details for a design recommendation and quotation.(See page 3 for our simple data input sheet). Trace Heating PRODUCTS7 Trace Heating PRODUCTS6 self regulating XTVE lectric Trace Heating for process temperaturemaintenance applications up to 120OC which may be subject to steam XTV family of self regulating parallel circuit heatingcables is used for process temperature maintenanceof pipes and vessels in industrial environments wherethere may be a requirement to steam clean.

7 It can alsobe used for frost protection of large diameter pipesand other applications requiring high temperatureexposure capability. XTV heaters are rated T3 and T2(20 XTV2 - CT) for hazardous area cable Services with application details for a FREE design recommendation and quotation.(See page 3 for our simple data input sheet). self regulating KTVE lectric Trace Heating for process temperaturemaintenance applications up to 150OC which may be subject to steam KTV family of self regulating parallel circuit heatingcables is used for industrial process temperature maintenance of pipes and vessels, where there may be a requirement for a high temperature exposure capability.

8 KTV heaters are rated T3 and T2 for hazardous area cable Services with application details for a FREE design recommendation and quotation.(See page 3 for our simple data input sheet).High TemperaturePower Limiting VPLE lectric Trace Heating designed for hightemperature industrial applications up to250OC temperature is a family of power limiting cables which can beused for frost protection and process temperaturemaintenance requiring high power output and/orhigh temperature exposure. VPL can provide processtemperature up to 230OC and can withstand routineexposure to 250OC with power of f.

9 Power limitingcables are parallel circuit heaters formed by a coiledresistor alloy Heating element wrapped around twoparallel conductors. this parallel construction allows itto be cut to length on cable Services with application details for a FREE design recommendation andquotation. (See page 3 for our simple data input sheet).Constant Wattage IHTIHT parallel circuit medium power constant output heater for non hazardous is designed for high temperature processmaintenance applications particularly in chemicallyaggressive environments such as animal parallel circuit zone construction enables IHTto be cut to length and terminated on cable Services with application details for a FREE design recommendation and quotation.

10 (See page 3 for our simple data input sheet).Constant Wattage FHTFHT constant wattage parallel circuit Heating cables for high power industrial applications including hazardous is designed for high temperature applications andcan provide process temperature maintenance up to150OC and can withstand exposure up to 260OC powerof f. The parallel construction allows it to be cut tolength on site and its round shape provides excellentflexibility during cable Services with application details for a FREE design recommendation and quotation.(See page 3 for our simple data input sheet).Constant Wattage FG220 Versatile flexible parallel circuit heater for mediumpower applications in non hazardous is a family of silicone rubber jacketed highlyflexible constant wattage heaters suitable for avariety of industrial applications in non hazardous,non chemicalaggressive industrial environments.


Related search queries