D2 FloProt Control ValveThe Type D2 FloProt Control Valve (figure 1) is acompact, rugged Valve designed for on-off Valve is ideal for use as a dump Valve on gasseparators and scrubbers. It is also well suited forother high pressure applications in natural gasproduction, compression, and processing. The TypeD2 FloPro Valve has threaded end connections andis available in a 1-inch globe style or angle does not assume responsibilityfor the selection, use, or maintenanceof any product. Responsibility forproper selection, use, andmaintenance of any Fisher productremains solely with the purchaser Flow Rates The FloProfeature allows easy setting of , , and flow rates, eliminating the need for more thanone port size. See figure Valve Body Styles The Type D2 FloPro Control Valve is available in both globe andangle style construction, see figure 1.

www.Fisher.com D102816X012 Type D2 FloPro Control Valve The Type D2 FloPro control valve (figure 1) is a compact, rugged valve designed for on-off control. This valve is ideal for use as a dump valve on gas separators and scrubbers.

Tags:

  Solutions, Electrical, Types, Control, Valves, Type d2 flopro control valve electrical solutions, Flopro, Type d2 flopro control valve

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Type D2 FloPro Control Valve - Electrical Solutions …

1 D2 FloProt Control ValveThe Type D2 FloProt Control Valve (figure 1) is acompact, rugged Valve designed for on-off Valve is ideal for use as a dump Valve on gasseparators and scrubbers. It is also well suited forother high pressure applications in natural gasproduction, compression, and processing. The TypeD2 FloPro Valve has threaded end connections andis available in a 1-inch globe style or angle does not assume responsibilityfor the selection, use, or maintenanceof any product. Responsibility forproper selection, use, andmaintenance of any Fisher productremains solely with the purchaser Flow Rates The FloProfeature allows easy setting of , , and flow rates, eliminating the need for more thanone port size. See figure Valve Body Styles The Type D2 FloPro Control Valve is available in both globe andangle style construction, see figure 1.

2 The anglestyle allows for direct tank Service Trim The Valve plug andseat ring are constructed from solid R30006 (Alloy6), providing excellent wear capability for erosiveservice and longer trim D2 Packing System The ENVIRO-SEAL D2 packing system provides animproved stem seal to prevent the loss of valuable orhazardous process fluids or gases. It featureslive-loading, providing reduced STYLEANGLE STYLEF igure 1. Type D2 FloPro Control ValveProduct :D2 December 2004D2 FloPro ValveD2 FloPro ValveProduct :D2 December 2004 2 GLOBE STYLE AIR-TO-OPENANGLE STYLE AIR-TO-OPENW9005-1W9006-1 Figure 2. Type D2 FloPro ConstructionsDNACE MR0175 Service-Ready NACE trim isthe standard construction for the D2 FloPro controlvalve. The Valve body, bonnet, and trim materialscomply with the recommendations of Class 900 Valve assembly is designedand specified for ASME Class 900 Temperature Materials Valve andactuator construction materials allow use in lowtemperature applications of 46 Actuator The Type D2 FloPro actuator can be converted in the field fromAir-to-Open to Air-to-Close actuator action.

3 (Conversion to Air-to-Close actuator action requiresremoving four springs from the actuator casingconfiguration.) (Conversion to Air-to-Open actuatoraction requires adding four springs to the actuatorcasing configuration.)DEasy Installation Compact design allowsinstallation where space is at a Maintenance Screwed bonnet/bodyjoint allows repair or maintenance with a minimum oftools and without removing the Valve body from thepiping FloPro ValveProduct :D2 December 2004 INCH FLOW RATE(Cv = 6) INCH FLOW RATE(Cv = 4) INCH FLOW RATE(Cv = 2)FLOW ADJUSTER123123 FloPro TRAVELINDICATORW8330-1 Figure 3. Travel and Flow Coefficients19B8490-BE0783216( )DIAMETER1/4 INCH NPTVENT CONNECTION1/4 INCH NPTSUPPLY CONNECTION1-INCH NPT76( )194( )43( )51( )DIAMETER60( )120( )mm(INCH)Figure 4.

4 Type D2 Globe Valve Dimensions (Air-to-Open Configuration Shown)D2 FloPro ValveProduct :D2 December 2004 4216( )DIAMETER1/4 INCH NPTVENT CONNECTION76( )mm(INCH)1/4 INCH NPTVENT CONNECTION251( )232( )178( )1 - 11 1/2 NPT2 - 11 1/2 NPT1 - 11 1/2 NPT55( )51( )ENGAGEMENTLINEGE13418-AE0972 Figure 5. Type D2 Angle Valve Dimensions (Air-to-Open Configuration Shown)D2 FloPro ValveProduct :D2 December 2004 5 SpecificationsValve Assembly Pressure Class(1)ASME Class 900 Temperature Range(1)155 bar from 46 to 93 C, and 150 bar at 149 C.(2250 psig from 50 to 200 F, and 2185 psig at300 F)Maximum Allowable Pressure Drop(1)Flow Down(2) Maximum Inlet Pressure: 155 bar (2250 psig)Maximum Outlet Pressure: 103 bar (1500 psig)Flow UpMaximum Inlet Pressure: 103 bar (1500 psig)Maximum Outlet Pressure: 103 bar (1500 psig)Shutoff ClassificationANSI Class IV ANSI/FCI 70-2 and IEC 60534-4 Construction MaterialsValve Body and Bonnet: ASME SA 352 LCCS tress relievedValve Plug and Seat: (R0006) Alloy 6 Valve Stem: (S31600) 316 SSTO-Rings: (HNBR) Hydrogenated NitrilePacking: PTFE/Carbon PTFEP acking Springs: (N07718) Inconel 718 Stem Bushing: (Ryton) PPSA ctuator Diaphragm: Nitrile/PolyesterActuator Springs.

5 Zinc-plated steelFlow CharacteristicFloPro CharacterizedFlow CoefficientsSee figure 3 Port Diameter13 mm ( inch)Maximum Travel13 mm ( inch) Valve Travel IndicationsSee figure 3 Approximate WeightGlobe Valve Body: kg (17 lb)Angle Valve Body: kg (18 lb)DimensionsSee figures 4 and 5 Material Temperature CapabilitiesValve Body Assembly: 46 to 149 C ( 50 to 300 F)Actuator Assembly: 46 to 93 C ( 50 to 200 F)Bonnet/Body ConnectionScrewed with leakoff bleedStandard Actuator ConfigurationThe D2 FloPro actuator is an Valve Body: Supplied as eitherAir-to-Open or Valve Body: Supplied as Air-to-Open onlyMaximum Actuator Casing bar (40 psig)Minimum Required Actuator Casing to bar (30 to 35 psig)Actuator Diaphragm Effective Area194 cm2 (30 square inches)Actuator Pressure Connections1/4 inch NPT female; see figure 4 for locations1.

6 The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be Standard flow FloPro ValveProduct :D2 December 2004 6 Ordering InformationNoteFisher does not assume responsibilityfor the selection, use, or maintenanceof any product. Responsibility forproper selection, use, andmaintenance of any Fisher productremains solely with the purchaser Marshalltown, Iowa 50158 USAC ernay 68700 France Sao Paulo 05424 BrazilSingapore 128461 The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they arenot to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or reserve the right to modify or improve the designs or specifications of such products at any time without does not assume responsibility for the selection, use or maintenance of any product.

7 Responsibility for proper selection, use and maintenance of any Fisher product remains solely with the purchaser and Controls International LLC 2001, 2004; All Rights Reserved Printed in USAENVIRO-SEAL, FloPro , and Fisher are marks owned by Fisher Controls International LLC, a member of the Emerson Process Managementbusiness division of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are theproperty of their respective owners. This product may be covered by one or more of the following patents: 5,129,625; 5,131,666; 5,056,757;5,230,498; 5,299,812; 6,698,449 B2; 6,695,000 B2; and 6,769,666 or under pending Process