UltraPly™ TPO Membrane
Air Permeance (Material) E 2178* < 0.004 ft³/ft² (0.02 L/(s*m²) Pass Pass *1. The ASTM 2178 values listed above are for the air permeance of the UltraPly TPO Membrane component only. 2. When system design includes an air barrier, please consult your Firestone Technical Services Advisor for additional roof system securement enhancements. 3.
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
UltraPly™ TPO Walkway Pad - firestonebpco.com
www.firestonebpco.comPlease contact Firestone Technical Services at 1-800-428-4511 for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications.
AG - UltraPly TPO Roofing Systems Application Guide
www.firestonebpco.com2. Consult container labels, Safety Data Sheets (SDS) and Technical Information Sheets (TIS) for specific safety instructions for all products used on the project. 3. Keep all adhesives, sealants and cleaning materials away from ALL ignition sources (i.e., flames, fire, sparks, etc.). Do not smoke while using these materials. 4.
Guide, Applications, Sheet, Data, Safety, Safety data sheet, Application guide
UltraPly™ TPO Roofing Systems
www.firestonebpco.comNov 29, 2021 · Guide for Designers UltraPly TPO UltraPly TPO Platinum UltraPly TPO InvisiWeld™ ... the roof system and integration with the rest of the structure envelope. Firestone Building Products UltraPly TPO Roofing Systems - Guide for Designers ... compliance with specifications other than Firestone’s. 3. Hail coverage:
UNA-CLAD METAL - firestonebpco.com
www.firestonebpco.comSTOCK PATTERN COLORS NON-STOCK PATTERN COLORS Available with minimum purchase amount and extended lead-time. Contact your local Sales Rep for more information.
Firestone Polyiso Insulation
www.firestonebpco.comefficiency, recycled content and zero ozone depletion. ul RooF assEMBliEs anD FiRE Ratings ul Rating RooF sloPE DECK tyPE insulation MEMBRanE class a Max. ½":12" combustible Min. 1" Resista ultraPly™ tPo Mechanically attached or fully adhered class a Max. 1":12" non-combustible Min. 1" Resista ultraPly™ tPo Mechanically attached or fully ...
ISOGARD™ GL Insulation
www.firestonebpco.comAll Firestone polyisocyanurate foam insulations use EPA accepted blowing agents. Firestone ISOGARD GL incorporates a HCFC-free blowing agent that does not contribute to the depletion of the ozone layer (ODP-free). Method of Application: 1. Insulation shall be neatly fitted to all roof penetrations, projections and nailers. 2.
Attachment Guide Supplemental Increased Wind Speed ...
www.firestonebpco.comFirestone Attachment Guide November 29, 2021 Attachment Guide & Supplemental Increased Wind Speed Warranty Attachment Guide November 2021 NOTE: The contents of this guide are considered accurate at time of posting. All information contained within should be validated for accuracy as it relates to
UltraPly™ Bonding Adhesive
www.firestonebpco.com6. Allow Bonding Adhesive to flash off until tacky. Touch down on the Bonding Adhesive surface with a clean, dry finger to be certain that the adhesive does not string. As you are touching the adhesive, pushing straight down to check for stringing, also push forward on the adhesive at an angle to ensure that the adhesive solvents have flashed
Adhesive, Bonding, Ultraply, Bonding adhesive, Ultraply bonding adhesive
ISOGARD™ HD Cover Board Coated Glass Facer High Density ...
www.firestonebpco.comStructural Concrete, 3000 psi (New & Existing) Please consult Membrane Design Guides on line at www.firestonebpco.comSteel, min. 22 ga to review specific information regarding fastener types appropriate for the type of deck and insulation in use. uge Lightweight Concrete* Plywood and OSB, min. ½" Gypsum, min. 2" NOT ACCEPTABLE
TIS 836 - TWIN JET
www.firestonebpco.comSpatter Application: Spatter Twin Jet at a rate of 60-70% coverage over the horizontal substrate and 75-85% at base tie-in locations, 2200 ft² (204 m²) to 2350 ft² (218 m²) per cannister set. • Do not apply Twin Jet Adhesive to the roof membrane. Keep lap areas of XR membrane clean and free of Twin Jet Adhesive overspray.
Related documents
NIBCO CHEMICAL RESISTANCE GUIDE FOR VALVES & FITTINGS
howellpipe.comand ozone resistance. It is fairly good with ketones and alcohols ... Because of this extensive chemical compatibility, which spans considerable concentration and temperature ranges, fluorocarbon elastomers have gained wide acceptance as a mate- ... dard material for bodies and bonnets of Class 125 and 250 iron. NIBCO INC.
Compatibility, Chemical, Material, Ozone, Chemical compatibility
700 Series ICP-OES User's Guide - Agilent
www.agilent.comThe material contained in this document is provided “as is,” and is subject to being changed, without notice, in future ... Electromagnetic Compatibility 15 . South Korean Class A EMC declaration 16 . ... ozone, vapors and fumes generated by the plasma can be hazardous, and ...
SKF Seal Handbook SKF - Tri-State Bearing
www.tristate-bearing.comcompatibility with higher temperatures up to 300°F (149°C), and even to 350°F (177°C) with some fluids. They are well suited for use with extreme pressure (EP) lubricants and have higher resistance to oxidation and ozone. They should not be used with water or at temperatures below -40°F (-40°C). Polyacrylates are not
CHEMICAL COMPATIBILITY CHART VITON
www.kelco.com.auCHEMICAL COMPATIBILITY CHART . VITON . Our products can be exposed to a huge variety of chemicals. The data table below is an application guide, and indicates the . resistance of the specific thermoplastics we use in the construction of our products, to common chemicals. The data given should be used cautiously, and as a guide only.
Chart, Compatibility, Chemical, Viton, Chemical compatibility chart, Chemical compatibility chart viton