UniSens - Gas Monitors and Water Quality Monitors

Universal 2-Wire Gas World of Single Transmitter Is All You was, monitoring multiple gases meant using differentgas transmitters each with its own maintenanceproblems, its own appetite for spare parts, its owninstallation headaches, and so on, and so again, thanks to ATI. Our UniSens universal 2-wiregas transmitter handles 28 different gases, providing themost economical and flexible gas measurement systemavailable today. Combining universal electronics, benchcalibration capability, automatic sensor verification, faultdetection and alarming, and superior sensor technology, UniSens is your best transmitter is designed for ambient gas monitoring in allkinds of industrial environments: gas storage areas, gascompressor rooms, process piping galleries, rail car sidings,analyzer shacks, gas cabinets, chemical process areas, fact, the UniSens transmitter can be used mostanywhere that hazardous gas conditions might developeither through leakage or through natural buildup.

One Transmitter Is All You Need. Time was, monitoring multiple gases meant using different gas transmitters — each with its own maintenance problems, its own appetite for spare parts, its own

Tags:

  Monitor, Sunnie

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of UniSens - Gas Monitors and Water Quality Monitors

1 Universal 2-Wire Gas World of Single Transmitter Is All You was, monitoring multiple gases meant using differentgas transmitters each with its own maintenanceproblems, its own appetite for spare parts, its owninstallation headaches, and so on, and so again, thanks to ATI. Our UniSens universal 2-wiregas transmitter handles 28 different gases, providing themost economical and flexible gas measurement systemavailable today. Combining universal electronics, benchcalibration capability, automatic sensor verification, faultdetection and alarming, and superior sensor technology, UniSens is your best transmitter is designed for ambient gas monitoring in allkinds of industrial environments: gas storage areas, gascompressor rooms, process piping galleries, rail car sidings,analyzer shacks, gas cabinets, chemical process areas, fact, the UniSens transmitter can be used mostanywhere that hazardous gas conditions might developeither through leakage or through natural buildup.

2 Interchangeable Sensing Modules Auto-Test Sensor Verification Non-Intrusive Magnetic Controls 28 Different Gases Off-Site Calibration Integral LCD Display Output Simulation CSA Approved Intrinsically Safe & Explosion ProofUnsurpassed Features:ATI Presents A Simpler ApproachTo Toxic Gas KeeperPowered by an ordinary C cell,the Sensor Keeper maintainssensors in stable operatingcondition for up to 6 months. Sensor Keepers are useful notjust for transporting sensors to and from the field, but forkeeping calibrated spares on the shelf. They also let uscalibrate sensors at the factory, and ship them forimmediate installation and Sensing ModulesATI sensing modules consist of an electrochemical gasdiffusion sensor and a solid state memory and manufactured exclusively by ATI, ourelectrochemical sensors provide excellent response time,maximum selectivity, and superior temperature stability forreliable gas sensing in a wide range of environments.

3 Thecompanion memory assembly stores operationalinformation and calibration constants, along with gassensor identification, sensing module range, and softwarerevision level. Complete sensing modules are housed inconvenient snap-in packages that mate easily with unique combination of sensor and memory letsyou calibrate sensing modules with any UniSenstransmitter. So instead of calibrating in the field, you canbench calibrate sensing modules with a spare transmitter;once the sensors are snapped into a field transmitter, theircalibration constants upload automatically.* Indicates Auto-Test *0-100 PPM50/500 PPMC arbon Monoxide*0-100 PPM50-500 PPMH ydrogen0-4%2000 PPM/10%Nitric Oxide0-50 PPM25/500 PPMO xygen0-25%10/100%Phosgene0-1 PPM1/100 PPMB romine*0-1 PPM1/100 PPMC hlorine0-10 PPM1/100 PPM Chloride Dioxide*0-1 PPM1/100 PPMF luorine*0-1 PPM1/100 PPMH ydrogen Peroxide0-10 PPM10/100 PPMI odine*0-1 PPM1/100 PPMO zone*0-1 PPM1/100 PPMH ydrogen Chloride* 0-20 PPM 10/200 PPMH ydrogen Cyanide*0-20 PPM10/200 PPMH ydrogen Fluoride*0-20 PPM10/200 PPMH ydrogen Sulfide*0-50 PPM10/500 PPMN itrogen Dioxide*0-20 PPM5/200 PPMS ulfur Dioxide*0-20 PPM10/200 PPMA rsine0-1000 PPB1000 PPB/100 PPMD iborane0-1000 PPB1000 PPB/100 PPMG ermane0-1000 PPB1000 PPB/100 PPMH ydrogen Selenide0-1000 PPB1000 PPB/100 PPMP hosphine0-1000 PPB1000 PPB/100 PPMS

4 Ilane0-10 PPM1000 PPB/100 PPMAcid Gases*0-10 PPM10/100 PPME thylene Oxide0-20 PPM20/200 PPMF ormaldehyde0-20 PPM20/200 PPMA lcohol0-500 PPM500/2000 PPMGas GeneratorH2Cl2 COSO2NH3SH2 SensorAuto-Test, for Savings and now, the manpower required for sensor testinghas been the most expensive part of any toxic gasdetection system. Available on many ATI sensingmodules, our optional Auto-Test gas generator can cuttesting costs dramatically by automatically verifyingsensor s a simple system. The Auto-Test gas generator iscoupled to the end of the sensor as an integral part ofthe sensing module. Every 24 hours, the transmitteractivates the generator and Monitors the sensor forresponse. If the sensor responds properly, the systemreverts to normal operation; if it fails, output is driven mA to signal trouble.

5 (During testing, the outputsignal is held at the pre-test value.)The transmitter maintains a log of completed tests,and can display the time until the next scheduled operator can manually activate Auto-Test, Transmitter ModuleThe UniSens microcomputer-controlled transmitterprovides a local digital display and a 4 20 mA analogoutput proportional to gas concentration. It works withany ATI sensing module, configuring its own displayand output range automatically based on data readfrom the module s memory. Zero and calibration data isalso read into memory, so the transmitter isautomatically calibrated when it s connected to acalibrated controls on the front of the transmitterallow field calibration, manual activation of the Auto-Test feature (if installed), and review of sensingmodule data including gas type, range, and number ofsuccessful Auto-Tests.

6 The transmitter can also act as ananalog output simulator to facilitate complete looptesting. Outputs of , , and mA are selectablevia the front panel, along with a trouble signal of transmitter is housed in a durable cast-aluminum shell with an 11-pin octal base for easyinstallation and removal. And since UniSenstransmitters are 100% interchangeable, one unit canserve as a backup for every type of gas in Type:Customer-selected from available listRange:Supplied with standard range foreach gas unless otherwise specifiedDisplay:4-1/2 digit LCDA ccuracy:Generally 5% of value, but limitedby available calibration gas accuracyElectronic Repeatability: 1%Electronic Linearity: drift:Sensor dependent, but generallyless than 2% of full scale per month,non-cumulativeSpan drift:Application dependent, but gener-ally less than 3% per :12 30 VDCO utput:Loop-powered 4-20 mA, 675 ohmsmaximum at 24 VDCLoop Simulation:Operator selectable outputs of 4,12, 20, and mA (trouble indictor)Enclosure:NEMA 4X and Explosion-proof castaluminum, Class 1, Div.

7 1, Groups B,C, & D, CSA approvedControls:Magnetic controls activated exter-nally through glass windowOperating Temperature:-30 to +55 C (except oxygen,which is -10 to +55 C)Sensor:Modular plug-in unit with calibra-tion data, gas type, and range insensor memorySensor Life:Average greater than two yearsSensor Pressure Limits:7 30 PSIA (05 2 Bar)Weight:4 lbs. ( Kg.)SpecificationsAccessoriesTypical ApplicationsSplash Guard: Required for transmitters located outdoors or withAuto-Test, the clear polycarbonate splash guard providesprotection against rain and high Adapter: This fitting slides into the bottom of thesplash guard and allows easy connection of zero air and span Assembly:For applications requiring sample drawsystems, the flowcell seals the sensing module and permits theaddition of inlet and outlet fittings to pipe sample into and out ofthe Processing Pulp & Paper R & D Labs Semiconductor Plants Refineries Pharmaceuticals Food Processing Aluminum Refining Breweries Metals Processing Water Treatment Wastewater Treatment Electric Utilities Agricultural Chemicals Plastics Manufacturing Splash Guard and Flowcell AssemblyCalibration KitsTo insure accurate measurement, gastransmitters should be calibrated every3-4 months.

8 ATI offers convenient cali-bration kits that can be used for eitherbench or field calibration. Kits containspan gas, zero air, and a combinationpressure and flow regulator in a moldedplastic carrying case. Contact ATI fordetails on available Bromine 0-1 (10) PPM*11 Chlorine 0-10 (100) PPM*12 Chlorine Dioxide 0-1 (10) PPM*13 Fluorine 0-1 (10) PPM*14 Ozone 0-1 (10) PPM*15 Ammonia 0-100 (500) PPM*16 Carbon Monoxide 0-100 (500) PPM*18 Hydrogen 0-2000 PPM (0-4%)19 Oxygen 0-25% (0-100%)20 Phosgene 0-1 (10) PPM 21 Hydrogen Chloride 0-20 (100) PPM*22 Hydrogen Cyanide 0-20 (100) PPM*23 Hydrogen Fluoride 0-20 (100) PPM*24 Hydrogen Sulfide 0-50 (100) PPM*25 Nitric Oxide 0-50 (500) PPM26 Nitrogen Dioxide 0-20 (100) PPM*27 Sulfur Dioxide 0-20 (100) PPM*28 Arsine 0-1000 PPB (0-10 PPM)29 Diborane 0-1000 PPB (0-10 PPM)30 Germane 0-1000 PPB (0-10 PPM)31 Hydrogen Selenide 0-1000 PPB (0-10 PPM)32 Phosphine 0-1000 PPB (0-10 PPM)

9 33 Silane 0-10 PPM (0-1000 PPB)34 Hydrogen Peroxide 0-10 (100) PPM35 Iodine 0-1 (10) PPM* 36 Acid Gases 0-10 (100) PPM37 ETO 0-20 (0-200) PPM38 Formaldehyde 0-20 (0-200) PPM39 Alcohol: Contact factoryRepresented By:How To OrderModel A12-CC-DDDD-E-F UniSens TransmitterSuffix CC- Gas Type:*Indicates that Auto-Test is available for standard the measurement range using a 4-digit number representing the full scale value. For 0 10 PPM chlorine, the codewould be 0010. For 0 100 PPM ammonia, the code would be 0100. The standard ranges are shown under Suffix C above. Analternate range is shown in parentheses. There is no added price for the alternate F Auto-Test Option1 Sensor without Auto-Test Generator2 Sensor with Auto-Test Generator (Requires Splash Guard #45-0047)Accessories45-0047 Splash Guard (Required for Auto-Test)00-0249 Flowcell Assembly00-0210 Sensing Module Keeper00-0248 Calibration Adapter (Requires 45-0047)1 PPM2 PPB3 %4 %LELS uffix E Units of MeasurementSuffix D Measurement RangeAnalytical Technology, Iron Bridge Drive Collegeville, PA 19426 Phone: 610/917-0991 Toll-Free: 800/959-0299 Fax: 610/917-0992E-Mail: (UK) LimitedBank Chambers, 33 Stamford StreetMossley, Aston-u-Lyne OL5 0 LLPhone: +44 (0) 1457 832800 Fax: +44 (0) 1457 83950E-Mail.


Related search queries