11:32:56 PM 4/11/2006. PC1832, PC1832 , C:\DLS\Folders\Downloads\ user Access Codes Access code code Bypass Escort Phone#1 Phone#2 Bell One Comments code 01 AAAA No No No No No No code 02 AAAA No No No No No No code 03 AAAA No No No No No No code 04 AAAA No No No No No No code 05 AAAA No No No No No No code 06 AAAA No No No No No No code 07 AAAA No No No No No No code 08 AAAA No No No No No No code 09 AAAA No No No No No No code 10 AAAA No No No No No No code 11 AAAA No No No No No No code 12 AAAA No No No No No No code 13 AAAA No No No No No No code 14 AAAA No No No No No No code 15 AAAA No No No No No No code 16 AAAA No No No No No No code 17 AAAA No No No No No No code 18 AAAA No No No No No No code 19 AAAA No No No No No No code 20 AAAA No No No No No No code 21 AAAA No No No No No No code 22 AAAA No No No No No No code 23 AAAA No No No No No No code

11:32:56 PM 4/11/2006 PC1832, PC1832 4.1, C:\DLS\Folders\Downloads\PC1832.Dsc Second System Option Code continued from Page 6... Disabled 3 Bell Squawk On Exit Delay No …

Tags:

  User, Code, Access, User access codes

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of User Code Partition Assignment User Access Codes

1 11:32:56 PM 4/11/2006. PC1832, PC1832 , C:\DLS\Folders\Downloads\ user Access Codes Access code code Bypass Escort Phone#1 Phone#2 Bell One Comments code 01 AAAA No No No No No No code 02 AAAA No No No No No No code 03 AAAA No No No No No No code 04 AAAA No No No No No No code 05 AAAA No No No No No No code 06 AAAA No No No No No No code 07 AAAA No No No No No No code 08 AAAA No No No No No No code 09 AAAA No No No No No No code 10 AAAA No No No No No No code 11 AAAA No No No No No No code 12 AAAA No No No No No No code 13 AAAA No No No No No No code 14 AAAA No No No No No No code 15 AAAA No No No No No No code 16 AAAA No No No No No No code 17 AAAA No No No No No No code 18 AAAA No No No No No No code 19 AAAA No No No No No No code 20 AAAA No No No No No No code 21 AAAA No No No No No No code 22 AAAA No No No No No No code 23 AAAA No No No No No No code

2 24 AAAA No No No No No No code 25 AAAA No No No No No No code 26 AAAA No No No No No No code 27 AAAA No No No No No No code 28 AAAA No No No No No No code 29 AAAA No No No No No No code 30 AAAA No No No No No No code 31 AAAA No No No No No No code 32 AAAA No No No No No No Duress code 33 AAAA No No No No No No Duress code 34 AAAA No No No No No No System Master 1234 Yes Yes Yes Yes No No Supervisor code 41 AAAA No No No No No No Supervisor code 42 AAAA No No No No No No user code Partition Assignment Access code Par 1 Par 2 Par 3 Par 4 Comments code 01 No No No No code 02 No No No No code 03 No No No No code 04 No No No No code 05 No No No No code 06 No No No No code 07 No No No No code 08 No No No No code 09 No No No No code 10 No No No No code 11 No No No No code 12 No No No No code 13 No No No No code 14 No No No No code 15 No No No No code 16 No No No No code 17 No No No No code 18 No No No No code 19 No No No No code 20 No No No No code 21 No No No No code 22 No No No No code 23 No No No No code 24 No No No No code 25 No No No No code 26 No No No No user code Partition Assignment continued on Page Page 4.

3 11:32:56 PM 4/11/2006. PC1832, PC1832 , C:\DLS\Folders\Downloads\ Zone 1 to 16 Definitions [001]. Zone Definition Comments Zone 01 (01) Delay 1. Zone 02 (03) Instant Zone 03 (03) Instant Zone 04 (03) Instant Zone 05 (04) Interior Zone 06 (04) Interior Zone 07 (04) Interior Zone 08 (04) Interior Zone 09 (00) Null Zone (Not Used). Zone 10 (00) Null Zone (Not Used). Zone 11 (00) Null Zone (Not Used). Zone 12 (00) Null Zone (Not Used). Zone 13 (00) Null Zone (Not Used). Zone 14 (00) Null Zone (Not Used). Zone 15 (00) Null Zone (Not Used). Zone 16 (00) Null Zone (Not Used). Zone 17 to 32 Definitions [002]. Zone Definition Comments Zone 17 (00) Null Zone (Not Used). Zone 18 (00) Null Zone (Not Used). Zone 19 (00) Null Zone (Not Used). Zone 20 (00) Null Zone (Not Used). Zone 21 (00) Null Zone (Not Used). Zone 22 (00) Null Zone (Not Used).

4 Zone 23 (00) Null Zone (Not Used). Zone 24 (00) Null Zone (Not Used). Zone 25 (00) Null Zone (Not Used). Zone 26 (00) Null Zone (Not Used). Zone 27 (00) Null Zone (Not Used). Zone 28 (00) Null Zone (Not Used). Zone 29 (00) Null Zone (Not Used). Zone 30 (00) Null Zone (Not Used). Zone 31 (00) Null Zone (Not Used). Zone 32 (00) Null Zone (Not Used). System Times [005]. P1 P2 P3 P4. Entry Delay 1 030 030 030 030 (001-255 Seconds). Entry Delay 2 045 045 045 045 (001-255 Seconds). Exit Delay 120 120 120 120 (001-255 Seconds). Bell Cut-Off 004 (001-255 Minutes). Installer's code [006]. Installer's code 5555. Master code [007]. Master code 1234. Maintenance code [008]. Maintenance code AAAA Enter Decimal Data (AAAA or AAAA00 to disable). PC1832 PGM's 1 & 2 (Onboard) [009]. Attributes Definition PGM 01 (19) (*71) Command Output #1.

5 PGM 02 (10) System Event (with Event Options). PC5208 PGM's 3 to 10 [010]. Attributes Definition PGM 03 (01) Burglary and Fire Bell Output PGM 04 (01) Burglary and Fire Bell Output PGM 05 (01) Burglary and Fire Bell Output PGM 06 (01) Burglary and Fire Bell Output PGM 07 (01) Burglary and Fire Bell Output PGM 08 (01) Burglary and Fire Bell Output PGM 09 (01) Burglary and Fire Bell Output PGM 10 (01) Burglary and Fire Bell Output PC5204 PGM's 11 to 14 [011]. Attributes Definition PGM 11 (01) Burglary and Fire Bell Output PGM 12 (01) Burglary and Fire Bell Output PGM 13 (01) Burglary and Fire Bell Output PGM 14 (01) Burglary and Fire Bell Output Keypad Lockout Options [012]. Number Invalid Codes Before Lockout 000 000-255 Invalid Codes Lockout Duration 000 000-255 Minutes First System Option code [013]. Setting Option Option Enabled Option Disabled Disabled 1 Normally Closed Loops End-Of-Line Resistors Disabled 2 Double End-Of-Line Resistors Single End-Of-Line Resistors Enabled 3 Panel Shows All Troubles While Armed Panel Shows Only Fire Troubles While Armed Disabled 4 Tampers/Faults Do Not Show As Open Tampers/Faults Show As Open Enabled 5 Autoarm Schedule In [*][6] And Installer's Autoarm Schedule in Installer's Programming Only Enabled 6 Audible Exit Fault Enabled Audible Exit Fault Disabled Enabled 7 Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past Shutdown Disabled 8 Temporal Three Fire Signal Enabled Standard Pulsed Fire Signal Second System Option code [014].

6 Setting Option Option Enabled Option Disabled Disabled 1 Arm/Disarm Bell Squawk Enabled Arm/Disarm Bell Squawk Disabled Disabled 2 Bell Squawk During Auto-Arm No Bell Squawk During Auto-Arm Second System Option code continued on Page Page 6. 11:32:56 PM 4/11/2006. PC1832, PC1832 , C:\DLS\Folders\Downloads\ Second System Option code continued from Page Disabled 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay Disabled 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay Disabled 5 Bell Squawk On Trouble No Bell Squawk On Trouble Enabled 6 Audible Exit With Urgency Silent Exit Delay Disabled 7 Exit Delay Termination Enabled Exit Delay Termination Disabled Disabled 8 Fire Bell Is Continuous Fire Bell Follows Bell Cut-off Third System Option code [015]. Setting Option Option Enabled Option Disabled Enabled 1 [F] Key Enabled [F] Key Disabled Disabled 2 [P] Key Audible (Bell/Beeps) [P] Key Silent Disabled 3 Quick Exit Enabled Quick Exit Disabled Enabled 4 Quick Arming Enabled Quick Arming Disabled (Funct.)

7 Keys Req. code ). Disabled 5 code Required For Bypassing No code Required Disabled 6 Master code Not Changeable Master code Changeable Enabled 7 TLM Enabled TLM Disabled Disabled 8 TLM Audible When Armed TLM Trouble Only When Armed Fourth System Option code [016]. Setting Option Option Enabled Option Disabled Enabled 1 AC Trouble Displayed AC Trouble Not Displayed Disabled 2 Trouble Light Flashes if AC Fails Trouble Light Does Not Flash on AC Failure Disabled 3 Blank Keypad When Not Used Keypad Active Always Disabled 4 code Required to Remove Keypad Blanking No code Required Enabled 5 Keypad Backlighting is Enabled Keypad Backlighting is Disabled Disabled 6 Power Save Mode Enabled Power Save Mode Disabled Disabled 7 Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed Disabled 8 Keypad Tampers Enabled Keypad Tampers Disabled Fifth System Option code [017].

8 Setting Option Option Enabled Option Disabled Enabled 1 WLSKEY Does Not Use Access Codes WLSKEY Uses Access Codes Disabled 2 RF Jam Log After 5 Minutes RF Jam Log After 30 Seconds Disabled 3 Audible RF Jam Trouble Beeps Silent RF Jam Trouble Beeps Disabled 4 Double Hit Enabled Double Hit Disabled Disabled 5 Late to Close Enabled Late to Close Disabled Disabled 6 Daylight Savings Time Enabled Daylight Savings Time Disabled Enabled 7 Periodic Camera Test Enabled Periodic Camera Test Disabled Disabled 8 Squawk On Away Arming/Disarming Only Bell Squawk On All Arming/Disarming Sixth System Option code [018]. Setting Option Option Enabled Option Disabled Disabled 1 Test Transmission Exception Enabled Test Transmission Exception Disabled Disabled 2 Verbal Chime is Enabled Verbal Chime is Disabled Disabled 3 Verbal Alarm is Enabled Verbal Alarm is Disabled Disabled 4 Water-flow Silence Inhibit Enabled Water-flow Silence Inhibit Disabled Disabled 5 Keypad Buzzer Follows Bell Enabled Keypad Buzzer Follows Bell Disabled Disabled 6 Cross Zoning is Enabled Police code is Enabled Disabled 7 Exit Delay Restart Enabled Exit Delay Restart Disabled Disabled 8 System AC Failure Trouble Beeps Enabled System AC Failure Trouble Beeps Disabled Seventh System Option code [019].

9 Setting Option Option Enabled Option Disabled Disabled 1 Audible Wireless Zone Fault while Armed Wireless Zone Fault doesn't sound Bell Disabled 2 Troubles Are Latching Troubles Follow Restore Disabled 3 First Zone in Alarm Enabled First Zone in Alarm Disabled Disabled 4 R-Button Feature Enabled R-Button Feature Disabled Disabled 5 Keybus Fault Sounds Bell Keybus Fault Does Not Sound Bell Disabled 6 Green Keypad LED/Power Indication Green Keypad LED/Ready Indication Disabled 7 [*][6] Accessible by All Users [*][6] Accessible by Master code Only Disabled 8 Reset Required After 2 Activations/Cross Zone Police code Reset Required After One Activation Keypad Zone Assignments [020]. Keypad 1 Zone 00. Keypad 2 Zone 00. Keypad 3 Zone 00. Keypad 4 Zone 00. Keypad 5 Zone 00. Keypad 6 Zone 00. Keypad 7 Zone 00. Keypad 8 Zone 00.

10 Eighth System Option code [021]. Setting Option Option Enabled Option Disabled Disabled 1 Access code Entry Blocked During Entry Delay Access code Not Blocked During Entry Delay Disabled 2 Transmission Delay During Entry Delay Transmission Delay Always (standard). Disabled 3 5 Second Keypad Blanking 30 Second Keypad Blanking Disabled 4 Remote Reset Enabled Remote Reset Disabled Disabled 5 Engineer's Reset Enabled Engineer's Reset Disabled Disabled 6 Keyswitch Disarming During Entry Delay Only No Entry Delay for Keyswitch Disarm Disabled 7 Installer Access Follows DLS Window Installers Can Be Accessed At Any Time Disabled 8 Arming Inhibit for All Troubles Troubles Do Not Inhibit Arming Ninth System Option code [022]. Setting Option Option Enabled Option Disabled Disabled 1 Access code Required for *1, *2, *3 No Access code Required for *1, *2, *3.