Transcription of VDS 200Q SERIES - EM Test
1 DATA SHEET > VDS 200Q- SERIES > 20180709. VDS 200Q SERIES . 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY. SIMULATOR AND DC VOLTAGE SOURCE. FOR TESTS ACCORDING TO .. > ISO 16750-2. > OEM LV 124. > LV 148. > Audi (Reference vehicles). > BMW - (Airbag ECU). > BMW 600 (Part 1). > BMW 600 (Part 2). > BMW GS 95002 (2010). > BMW GS 95003-2. > BMW GS 95024-2-1. > ISO 21848:2005. > ISO 14982. > ISO 7637-2:2004. > ISO 7637-2:2011. > OEM LV 124 (2013-02). > MBN LV 124-1. > OEM LV 148. > SAE J1113-11. > SAE J1113-11 ( ). > VW 80000. VDS 200Q - FOUR QUADRANT BATTERY SUPPLY SIMULATOR AND DC VOLTAGE SOURCE.
2 The VDS 200Q SERIES is used to simulate the various battery supply waveforms recommended by international standards and by car manufacturer requirements. Especially the manufacturer requirements are an important area covered by the VDS. 200Q SERIES as there is a large variety of requirements. Secondly, the VDS 200Q SERIES serve as powerful DC voltage supplies for the DUT during the tests with automotive transients. The VDS 200Q SERIES covers all three supply voltage categories (42. V, 24 V and 12 V). Their current capability ranges up to 100 A depending on the model and your application.
3 HIGHLIGHTS APPLICATION AREAS. > Voltage up to 60 V, 2 ranges AUTOMOTIVE. > Expandable to 80 V. > Current up to 200 A (600 A peak) MILITARY. > Four quadrant operation AVIONICS. > Fast step response time > Low output impedance > High Bandwidth > Temperature-controlled air cooling EM TEST > PAGE 1/6. DATA SHEET > VDS 200Q- SERIES > 20180709. TECHNICAL DETAILS. MODEL OVERVIEW TECHNICAL DETAILS. AVAILABLE VDS 200Q-MODELS VDS 200Q10. VDS 200Q10 Voltage Drop Simulator, Output Range -60 V - +60 V. 60 V / 10 A. Output current 0 A - 10 A, continuous VDS 200Q25 Voltage Drop Simulator, Bandwidth (-3dB) DC - 180 kHz full signal 60 V / 25 A.
4 Supply Voltage 1-phase 100/120/230 V 10%, VDS Voltage Drop Simulator, L, N, PE. 60 V / 25 A, 77 V / 20 A extended Dimensions 19"/6 HU. VDS 200Q50 Voltage Drop Simulator, Weight 37 kg 60 V / 50 A. VDS Voltage Drop Simulator, VDS 200Q25. 60 V / 50 A, 77 V / 40 A extended Output Range -15 V - +30 V / +60 V. VDS 200Q100 Voltage Drop Simulator, Output Current 0 A - 25 A, continuous 60 V / 100 A Peak current 75 A for 200 ms VDS Voltage Drop Simulator, Bandwidth (-3dB) DC - 150 kHz full signal 60 V / 100 A, 77 V / 80 A extended Supply Voltage 1-phase 100/120/230 V 10%, L, N, PE.
5 VDS Voltage Drop Simulator, 60 V / 150 A, Dimensions 19"/25 HU*). 77 V / 120 A extended Weight 230 kg VDS Voltage Drop Simulator, 80 V / 200 A, VDS 80 V / 160 A extended Output Range -20 V to +77 V. Output Current 0 A - 25 A, continuous Peak current 75 A for 200 ms Bandwidth DC - 150 kHz full signal Extended -20 V - +77 V (20 A max.), Envelope 150 - 250 kHz (40 Vpp max.). Supply Voltage 1-phase 100/120/230 V 10%, L, N, PE. Dimensions 19"/25 HU*). Weight 230 kg EM TEST > PAGE 2/6. DATA SHEET > VDS 200Q- SERIES > 20180709. TECHNICAL DETAILS. TECHNICAL DETAILS TECHNICAL DETAILS.
6 VDS 200Q50 VDS 200Q100. Output Range -15 V - +30 V / +60 V Output Range -15 V - +30 V / +60 V. Output Current 0 A - 50 A, continuous Output Current 0 A - 100 A, continuous Peak current 150 A for 200 ms Peak Current 300 A for 200 ms Bandwidth (-3dB) DC - 150 kHz full signal Bandwidth (-3dB) DC - 150 kHz full signal Supply Voltage 3-phase 200/400 V 10%, Supply Voltage 3-phase 200/400 V 10%, L1, L2, L3, PE L1, L2, L3, PE. Dimensions 19"/25 HU*) Dimensions 19"/38 HU**). Weight 275 kg Weight 450 kg VDS VDS Output Range -20 V to +77 V Output Range -20 V to +77 V. Output Current 0 A - 50 A, continuous Output Current 0 A - 100 A, continuous Peak current 150 A for 200 ms Peak Current 300 A for 200 ms Bandwidth DC - 150 kHz full signal Bandwidth DC - 150 kHz full signal Extended -20 V - +77 V (40 A max.
7 , Extended -20 V - +77 V (80 A max.), Envelope 150 - 250 kHz (40 Vpp max.) Envelope 150 - 250 kHz (40 Vpp max.). Supply Voltage 3-phase 200/400 V 10%, Supply Voltage 3-phase 200/400 V 10%, L1, L2, L3, PE L1, L2, L3, PE. Dimensions 19"/25 HU*) Dimensions 19"/38 HU**). Weight 275 kg Weight 450 kg *)Rack mounted, prepared to also **)Rack mounted, prepared to also include AutoWave, NR-RAC AutoWave include AutoWave and NR-RAC. drawer and PFM AutoWave drawer EM TEST > PAGE 3/6. DATA SHEET > VDS 200Q- SERIES > 20180709. TECHNICAL DETAILS. TECHNICAL DETAILS COMMON DATA (ALL MODELS).
8 VDS GENERAL. Output Range -20 V to +77 V Source impedance Zi = <10 mohm Output Current A - 150 A, continuous Operation 4 - quadrant, bipolar operation Peak Current 450 A for 200 ms Current limiter (not available for VDS 200Q10). 3x Imax: allows an inrush current of Bandwidth DC - 150 kHz full signal three times nominal current for 200. Extended -20 V - +77 V (120 A max.), ms before the current limiter starts Envelope 150 - 250 kHz (40 Vpp max.) 3x ictrl: allows an inrush current of three times the programmed current Supply Voltage 3-phase 200/208 or 400 V 10%, for 200 ms before the current limiter L1, L2, L3, PE.
9 Starts Dimensions 2 x 19"/34 HU**) Peak OFF: no inrush current above the set current value Weight approx. 650 kg Compensation STD: DC - 40 kHz HF: DC - >=150 kHz VDS CAP: DC - 3kHz Output Range -20 V to +80 V Recovery >90% of excursion within 25 us Output Current 0 A - 200 A, continuous Output rise time typ. <10 us, <3 us (high freq.). Peak Current 600 A for 200 ms Ripple voltage Ur <10 mVp-p, frequency min. 400 Hz Bandwidth DC - 150 kHz full signal Control Analog In Extended -20 V - +80 V (160 A max.), Cooling temperature-controlled air cooling Envelope 150 - 250 kHz (40 Vpp max.
10 Protection Thermal-Magnetic Circuit Breakers Gain 8 Depending on VDS 200Q model Supply Voltage 3-phase 200/208 or 400 V 10%, L1, L2, L3, PE. TRIGGER. connector: CEE 63 A. Automatic Automatic release of the events Dimensions 2 x 19"/34 HU**). Manual Manual release of a single pulse Weight approx. 900 kg External External release of a single pulse **)Rack mounted, prepared to also include AutoWave and NR-RAC. AutoWave drawer OUTPUT. DUT Supply +/- Safety laboratory or high current connectors Ext. trigger 5-15 V TTL, BNC connector CRO Trigger 5 V TTL-signal for oscilloscope INTERFACE.