E N E R G Y A N D C O M F O R T. Ventilation Test Instruments VELOCICALC . Multi-Function Ventilation Meter Series 9555. The Series 9555 are portable, hand held, Multi-Function Ventilation Test Instruments . These Instruments are available with or without a differential pressure sensor and are designed to work with a wide range of plug-in probes. The probes allow users to make various measurements by simply plugging in a different probe that has the features and functions best suited for a Model 9555 particular application. They are designed to measure air velocity, temperature, humidity, CO and CO2. Calculations include air flow, heat flow, turbulence, wet bulb and dew point temperature. The probes can be ordered at any time and include a data sheet with certificate of traceability. When its time for servicing, only the probe needs to be returned since all the Features and Benefits calibration data is stored within the probe.

VELOCICALC® Multi-Function Ventilation Meter Series 9555 The Series 9555 are portable, hand held, Multi-Function Ventilation Test Instruments. These instruments are available with

Tags:

  Tests, Instruments, Ventilation, Ventilation test instruments

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Ventilation Test Instruments - TSI, Inc

1 E N E R G Y A N D C O M F O R T. Ventilation Test Instruments VELOCICALC . Multi-Function Ventilation Meter Series 9555. The Series 9555 are portable, hand held, Multi-Function Ventilation Test Instruments . These Instruments are available with or without a differential pressure sensor and are designed to work with a wide range of plug-in probes. The probes allow users to make various measurements by simply plugging in a different probe that has the features and functions best suited for a Model 9555 particular application. They are designed to measure air velocity, temperature, humidity, CO and CO2. Calculations include air flow, heat flow, turbulence, wet bulb and dew point temperature. The probes can be ordered at any time and include a data sheet with certificate of traceability. When its time for servicing, only the probe needs to be returned since all the Features and Benefits calibration data is stored within the probe.

2 Best in class accuracy, especially in low flows Displays up to 5 measurements simultaneously Applications Optional smart plug-in probes, including CO2 and rotating HVAC commissioning and troubleshooting vane probes Clean room certification Large graphic display Testing and balancing Manual or continuous data logging Ventilation evaluations TRAKPROTM and LogDat2TM software included Thermal comfort studies Name test IDs meaningful to you IAQ investigations Bluetooth printer capability Process air flow testing Fast calibration and repair service just send in the probe TRUST. SCIENCE. INNOVATION. Specifications VELOCICALC. Models 9555, 9555-A, 9555-P, 9555-X and Optional Probes Optional Probes for VELOCICALC 9555 Series Multi-Functional Anemometers Velocity (Pitot Tube for Meter Models 9555, 9555-A, 9555-P). Range1 to m/s (250 to 15,500 ft/min) Model Probe Description Accuracy2 at m/s (2,000 ft/min). 960 Air Velocity and Temperature, straight probe Resolution m/s (1 ft/min).

3 962 Air Velocity and Temperature, articulating probe Duct Size 964 Air Velocity, Temperature, and Humidity, straight probe Dimensions 1 to 635 cm in increments of cm 966 Air Velocity, Temperature, and Humidity, articulating probe (1 to 250 inches in increments of in.). 995 4 in. (100 mm) Rotating Vane probe Volumetric Flow Rate 496 in. (35mm) Rotating Vane probe Range Actual range is a function of velocity, pressure, duct size, 792 Surface Temperature probe and K factor 794 Air Temperature probe Static/Differential Pressure (Meter Models 9555, 9555-A, 9555-P) 980 Indoor Air Quality probe Range3 to + mm Hg, -3735 to +3735 Pa 982 Indoor Air Quality probe, with CO. (-15 to +15 in. H2O). Accuracy 1% of reading 1 Pa, ( mm Hg, in. H2O). Resolution Pa, mm Hg ( in. H2O). Barometric Pressure 9555 9555-A 9555-P 9555-X. Range to mm Hg ( to in. Hg). Probe that measures velocity, includes includes Accuracy 2% of reading optional optional temperature, and humidity 964 probe 966 probe Instrument Temperature Range Operating (Electronics).

4 Pressure measurement . 5 to 45 C (40 to 113 F) Calculates flow, wet bulb, dew Operating (Probe) -10 to 60 C (14 to 140 F) point, standard/actual optional optional Storage -20 to 60 C (-4 to 140 F). Optional velocity and Data Storage Capabilities temperature probe . Range 26,500+ samples and 100 test IDs Optional rotating vane probe . Logging Interval Optional IAQ probes (CO2, 1 second to 1 hour temperature, humidity, CO).. Time Constant Data Logging (manual, auto save User selectable continuous).. External Meter Dimensions Data logging software . cm x cm x cm ( in. x in. x in.). Optional Bluetooth printer . Meter Weight with Batteries kg ( lbs.) Certificate of Calibration . 1 Pressure velocity measurements are not recommended below 1000 ft/min (5 m/s) and are Power Requirements best suited to velocities over 2,000 ft/min ( m/s). Range can vary depending on Four AA-size batteries or AC adapter barometric pressure. 2 Accuracy is a function of converting pressure to velocity.

5 Conversion accuracy improves when actual pressure values increase. 3 Overpressure range = 190 in. H O (360 mmHg, 48 kPa). 2. Probe Specifications Models 960, 962, 964, 966, 995, 496, 980, 982, 792 and 794. Thermoanemometer Range Accuracy Resolution Probe Dimensions Probe Models Length cm (40 in.). 3% of reading or m/s Tip dia. mm ( in.). 0 to 50 m/s (0 to 9,999 ft/min) m/s (1 ft/min). 962 ( 3 ft/min), whichever is greater4&5 Base dia. mm ( in.). -18 to 93 C (0 to 200 F) C ( F). C ( F)6 Articulating Section Length cm (6 in.). Articulating Knuckle dia. mm ( in.). Length cm (40 in.). 3% of reading or m/s 0 to 50 m/s (0 to 9,999 ft/min) m/s (1 ft/min) Tip dia. mm ( in.). ( 3 ft/min), whichever is greater4&5. 966 -10 to 60 C (14 to 140 F) C ( F) Base dia. mm ( in.). C ( F)6. 0 to 95% RH RH Articulating Section Length cm (6 in.). 3% RH7. Articulating Knuckle dia. mm ( in.). 3% of reading or m/s Length cm (40 in.). 0 to 50 m/s (0 to 9,999 ft/min) m/s (1 ft/min).

6 960 ( 3 ft/min), whichever is greater4&5 Tip dia. mm ( in.). -18 to 93 C (0 to 200 F) C ( F). C ( F)6 Base dia. mm ( in.). 3% of reading or m/s 0 to 50 m/s (0 to 9,999 ft/min) m/s (1 ft/min) Length cm (40 in.). ( 3 ft/min), whichever is greater4&5. 964 -10 to 60 C (14 to 140 F) C ( F) Tip dia. mm ( in.). C ( F)6. 0 to 95% RH RH Base dia. mm ( in.). 3% RH7. Rotating Vane Probe Models Range Accuracy Resolution Probe Dimensions to 30 m/s (50 to 6,000 ft/min) 1% of reading 4 ft/min ( m/s) 1 ft/min ( m/s). 995 Diameter 100mm (4 in.). 0 to 60 C (32 to 140 F) F ( C) C ( F). to m/s (100 to 3,000 ft/min) 3% of reading 4 ft/min ( m/s) 1 ft/min ( m/s). 496 Diameter 35mm ( in.). 0 to 60 C (32 to 140 F) F ( C) C ( F). IAQ Probe Models Range Accuracy Resolution Probe Dimensions 3% of reading or 50 ppm, 0 to 5000 ppm CO2 1 ppm CO2. whichever is greater9 CO2 Length cm ( in.). 980 0 to 95% RH RH. 3% RH7 Diameter cm ( in.). -10 to 60 C (14 to 140 F) C ( F).

7 F ( C)6. 3% of reading or 3 ppm, 0 to 500 ppm CO whichever is greater8 CO ppm CO. 0 to 5000 ppm CO2 3% of reading or 50 ppm, 1 ppm CO2 Length cm ( in.). 982. 0 to 95% RH whichever is greater9 CO2 RH Diameter cm ( in.). -10 to 60 C (14 to 140 F) 3% RH7 C ( F). F ( C)6. Thermocuple Probe Models Range Accuracy Resolution Probe Dimensions of reading + C. 792 -40 to 650 C (-40 to 1200 F) C ( F) Length cm (6 in.) Diameter ( of reading +2 F). of reading + C. 794 -40 to 650 C (-40 to 1200 F) C ( F) Length cm (6 in.) Diameter ( of reading +2 F). 4 Temperature compensated over an air temperature range of 40 to 150 F (5 to 65 C). 5 The accuracy statement begins at 30 ft/min through 9,999 ft/min ( m/s through 50 m/s). 6 Accuracy with instrument case at 77 F (25 C), add uncertainty of F/ F ( C/ C) for change in instrument temperature. 7 Accuracy with probe at 77 F (25 C). Add uncertainty of RH/ F ( RH/ C) for change in probe temperature.

8 Includes 1% hysteresis. 8 At 77 F (25 C). Add uncertainty of F ( C) for change in temperature. 9 At calibration temperature. Add uncertainty of F ( C) for change in temperature. Specifications are subject to change without notice. E N E R G Y A N D C O M F O R T. Ventilation Test Instruments TSI Incorporated - 500 Cardigan Road, Shoreview, MN 55126-3996 USA. USA Tel: +1 800 874 2811 E-mail: Website: UK Tel: +44 149 4 459200 E-mail: Website: France Tel: +33 491 95 21 90 E-mail: Website: Germany Tel: +49 241 523030 E-mail: Website: India Tel: +91 80 41132470 E-mail: China Tel: +86 10 8260 1595 E-mail: TRUST. SCIENCE. INNOVATION. Contact your local TSI Distributor or visit our website for more detailed specifications. P/N 5001016 Rev D Copyright 2008 by TSI Incorporat