Example: bachelor of science

Volatility - ROFA

A A A A A COMP COMP COMP COMP COMPANYANYANYANYANYAPPLICATIONS:APPLICAT IONS:APPLICATIONS:APPLICATIONS:APPLICATI ONS:VolatilityLIQUID PETROLEUM PRODUCTSSOLVENTSMETHODS:METHODS:METHODS: METHODS:METHODS:ASTM D 86 (0, 1, 2, 3, 4)ASTM D 850 ASTM D 1078 DIN 51751 (0, 1, 2, 3, 4)ISO 3405 (0, 1, 2, 3, 4)ADVANTAGES:Highly repeatabledistillation resultsReliable digital volumedetection unaffected byambient lightSmart, powerful PC-controlled operationand data managementDetects dry point fortesting of solvents andother difficult materialsSimple to operate andmaintainAutomatic Distillation AnalyzersHDA 627 AND HDA 628 HDA 628 s integrated computer systemconducts all programming, operation, anddiagnostic activities.

Compact footprint: 40 cm HDA 627 & HDA 628 Automatic Distillation Analyzers Herzog’s 40 years of leadership designing and manufacturing automatic distillation equipment

Tags:

  Volatility

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Volatility - ROFA

1 A A A A A COMP COMP COMP COMP COMPANYANYANYANYANYAPPLICATIONS:APPLICAT IONS:APPLICATIONS:APPLICATIONS:APPLICATI ONS:VolatilityLIQUID PETROLEUM PRODUCTSSOLVENTSMETHODS:METHODS:METHODS: METHODS:METHODS:ASTM D 86 (0, 1, 2, 3, 4)ASTM D 850 ASTM D 1078 DIN 51751 (0, 1, 2, 3, 4)ISO 3405 (0, 1, 2, 3, 4)ADVANTAGES:Highly repeatabledistillation resultsReliable digital volumedetection unaffected byambient lightSmart, powerful PC-controlled operationand data managementDetects dry point fortesting of solvents andother difficult materialsSimple to operate andmaintainAutomatic Distillation AnalyzersHDA 627 AND HDA 628 HDA 628 s integrated computer systemconducts all programming, operation, anddiagnostic activities.

2 The HDA 627, whichexcludes computer and monitor, provides aneconomic means of expanding the distillationsystem as your testing needs point and click to choose test programsand begin distillations. An extensive referencedatabase contains sample distillation programsfor many materials. For samples containingsingle boiling point components ( RFGs,oxygenates), Herzog Laboratory InformationSystem (HLIS) incorporates follow the heatcurve a unique feature that graphicallydisplays heater temperature versus recoveredvolume, and allows manual override of heatersettings throughout distillation.

3 Modifiedprograms can be stored and automaticallyapplied to similar samples, making it possibleto stay on method with the most difficult 627 HDA 628 Compact footprint: 40 cmHDA 627 & HDA 628 Automatic Distillation AnalyzersHerzog s 40 years of leadership designing and manufacturing automatic distillation equipmentculminates with their development of the most sophisticated ADAs ever built. They ve combined robustelectrical and mechanical systems that are the platform for all Herzog HDA analyzers, with an integrated,advanced computer complete with monitor, MS Windows operating system, and HLIS control distillations of petroleum products are fundamental to process control and productspecification.

4 The standard test methods require precise control of conditions including sample heating,temperature detection, condenser temperature, and recovery volume measurement. Automation of thisprocess optimizes productivity and FLEXIBILITY, PERFORMANCEI nitiate tests with only a few clicksContains only liter of heat transfer fluid, enablingrapid temperature changeCondenser temperatures can be changed betweenextremes of ASTM method D 86 groups 0 and 4within 5 minutes, independent of receiver temperatureRamping condenser temperature (for products withwide boiling range)

5 Prevents wax formation as heavycomponents condenseEnables receiving compartment temperature controlat setpoints from 0 to 60 C with programmed ramp-ing during distillationsDigital stepper motor and infrared sensor combine forultra-precise volume measurement; unaffected by am-bient lightTransparent receiver door allows convenient viewingof the recoveryCustom distillation curves record results at additionalvolume and temperature points or stop testing at aspecific volume/temperature pointSAFE, RELIABLE OPERATIONA utomatically detects method or safety violationsDetects and extinguishes fireLow mass, low voltage sample heater meets CE safetyrequirementsWithstands aggressive solvents & extensive operationError logs automatically signal problems.

6 Providingconvenient reports for verification & troubleshootingExpert sales and service from PAC s worldwide net-work of factory trained authorized representativesQuality construction and reliable operation backed bya limited parts and service warrantyIntensive customer training at your site or oursModular cabinet sections lift off quickly no toolsrequired for easy cleaning and service color, active matrixdisplay. Easily control HLIS software using a hand heldtrackball or by touchingthe screen. The system alsosupports standard mice,keyboards and a smart thermocouplesensor detects evaporationof the sample s last dropfrom the flask s new HLIS soft-ware can learn to detectdry point on difficultmaterials by memorizingthermocouple response atan operator indicated drypoint reliable recoveryvolume measurement isachieved with a precisionstepper motor, which ad-vances an optics carriagein ml increments asthe graduate fills, main-taining precise alignmentwith the meniscus.

7 Thesystem is digital and un-affected by ambient CONFIGURATIONS FOR ANY BUDGETH erzog LaboratoryInformation System(HLIS)HDA 627 HDA 627MP 626 HDA 628with HLISHDA 628with HLISHDA 628with HLISHDA 628with HLISC onforming to CE safetyrequirements, the HDA sextra responsive low mass,low voltage electric flaskheater enables the uniformdistillation rate that iscritical to repeatabledistillation COMPUTER-CONTROLLED FUNCTIONALITYD istillation Rate ControlThe system analyzes eachdistillation and suggests idealinitial heater settings, offeringthe option to automaticallysave these new settings in thedistillation program.

8 A micro-processor provides superiortemperature FunctionsQuickly view distillationprograms & results on-screen,narrowing searches to recordsmeeting specific criteria suchas sample ID, data range orproduct group. An error loggingsystem monitors system andoperator calibration functions areincluded ( pressure sensor,vapor thermometer, etc.). Fromthis screen, you can also verifyvolume the status of allmechanical and electricalsystems for verifications ofproper performance & routinepreventive PC-DRIVEN CONVENIENCE WITH HLISC ontrols and monitors up to 16 units from a single computer or centralHVU 628, enabling quick view of operation status and measurement valuesNetwork ready.

9 Automatic or on-demand data transfer to external computer,network, or LIMSI ncorporates built-in electronic calibration, self-test, and system diagnosticsfor reliable operationSophisticated Windows -based database management organizes testparameters and results for easy retrievalScroll through complete database or filter records by specific criteriaPassword protection with individual access profilesEasily upgrades as technology advancesHDA 628with HLISHDA 627 HDA 627MP 626PC with HLIS and economical 627s and 626s. Use up to 16 existing MP 626 stillsand programs with HLIS network and new HDA Master control HDA 628 with economical add on stills, includingHDA 627s and existing Model MP 626s.

10 Network up to 16 distillation alone or networked 628s with central or independent storageof program and results. Network up to 16 distillation ADDITIONAL INFORMATION:AMERICAS:PAC PETROLEUM ANALYZER COMPANY Pasadena Freeway Pasadena, Texas, USAP hone: [ ] | Fax: | , ASIA, AFRICA, MIDDLE EAST, AUSTRALIA:WALTER HERZOG GmbHBadstrasse 3-5, Box 1241D-97912 Lauda-K nigshofen - GERMANYP hone: +49 | Fax: +49 LOCAL REPRESENTATIVE:HDA 627 and HDA 628: Smart analysis, complete flexibilitySPECIFICATIONSSPECIFICATIONSS PECIFICATIONSSPECIFICATIONSSPECIFICATION SO rdering InformationModel HDA 628 Stand-Alone DistillaModel HDA 628 Stand-Alone DistillaModel HDA 628 Stand-Alone DistillaModel HDA 628 Stand-Alone DistillaModel HDA 628 Stand-Alone Distillation tion tion tion tion AnalAnalAnalAnalAnalyzeryzeryzeryzeryzer with integrated PC and HLIS (see below).