Example: dental hygienist

VP-4024B -24 VOLT DC POWER SUPPLY - Valcom, …

VSP-VP-4024 BIssue 61947724VP- 4024b -24 volt DC POWER SUPPLYINTRODUCTIONT hese instructions provide the specifications,installation and maintenance information for theVP- 4024b , -24 volt POWER VP- 4024b is a fully regulated -24 Vdc 4 amppower SUPPLY . The primary is protected by a circuitbreaker and the two amp outputs by fuses. Theoutput is floating with respect to ground, and the twooutputs may be connected together for one 4 ampoutput. The regulator will maintain -24 volts "2 Vover the rated range of input voltages and outputloads. A greater than 4 amp load on POWER up willcause the POWER SUPPLY to current limit and theoverload LED will light.

VSP-VP-4024B Issue 6 1 947724 VP-4024B-24 VOLT DC POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the

Tags:

  Power, Supply, 4024b 24 volt dc power supply, 4024b, Volt

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of VP-4024B -24 VOLT DC POWER SUPPLY - Valcom, …

1 VSP-VP-4024 BIssue 61947724VP- 4024b -24 volt DC POWER SUPPLYINTRODUCTIONT hese instructions provide the specifications,installation and maintenance information for theVP- 4024b , -24 volt POWER VP- 4024b is a fully regulated -24 Vdc 4 amppower SUPPLY . The primary is protected by a circuitbreaker and the two amp outputs by fuses. Theoutput is floating with respect to ground, and the twooutputs may be connected together for one 4 ampoutput. The regulator will maintain -24 volts "2 Vover the rated range of input voltages and outputloads. A greater than 4 amp load on POWER up willcause the POWER SUPPLY to current limit and theoverload LED will light.

2 Short circuit protection isprovided. Over voltage is provided to limit theoutput voltage to approximately -28 volts should afailure occur within the POWER VP- 4024b is designed to be used with - All Valcom page control units Valcom one-way amplified speaker assemblies Any application where -24 Vdc filtered talkbattery is requiredDesign Features Regulated -24 volts DC "A" battery Two 2 amp fused outputs Outputs may be connected for one output total 4amps at 25 degrees C Input circuit breaker protected LED indication of output overload Full current limiting Over voltage protection Floating output Full electronic

3 SupplyNominal SpecificationsPower RequirementsInput Voltage:105-120 Vac, 60 Hz, 150 watts "H x W x "D ( H x W x D)Weight:12 lbs. ( kg)Output Characteristics: -24 Vdc regulated "2V "A" battery Ripple 10 millivolts RMS max. Two 2 amp outputsINSTALLATIONThe VP- 4024b is designed to be wall mounted within7 feet of an AC receptacle. A cold water pipe orearth ground should be connected to the local groundscrew terminal using 12 AWG or larger ground Connections to Valcom page control units areshown in Figure 1. When using the VP- 4024b with Valcom pageequipment, a strap may be added from the localground terminal to either of the ground outputs.

4 When installing Valcom one-way amplified horns, connect the white and black wires of thehorn to the POWER SUPPLY -24V and groundterminals respectively. When installing Valcom one-way speakersconnect the -24V and ground terminals of thespeaker to the corresponding POWER : Each 24 Vdc screw terminal is fused by a2 amp WER 2 type fuse. Therefore, whenconnecting equipment to this POWER SUPPLY , the loadshould be distributed between the (2) 2 amp outputterminals and each load should not exceed 2 Installation Instructions(For use when local codes require conduit to powersupply)Before beginning this procedure, disconnect powersupply from AC service and customer connections.

5 Cover of SUPPLY . Remove the six (6)screws holding the faceplate to the cabinet. pliers, squeeze the strain reliefbushing associated with the AC input cord. This enables the removal of the POWER cordand strain relief bushing from the unit. faceplate from cabinet. Disconnectthe POWER cord leads from the SUPPLY - blackwire from the circuit breaker; white wirefrom the transformer; green wire from thechassis connection. a knockout punch (Greenlee #3807 orequivalent), enlarge the POWER cord accesshole to " diameter to accommodate a1/2" trade side conduit fitting. conduit fitting and run the AC inputleads through the fitting.

6 Connect asfollows:NOTE: The minimum recommended wiresize for AC input leads is 18 AWG; use wirerated for at least 105 degrees C. the AC input green/groundingconductor and the green ground wire fromthe faceplate to the chassis connection forthe ground wiring. the black wire to the circuit breakerterminal using a .250" tab receptacle.* the white wire to the transformerterminal using a .250" tab receptacle.* faceplate to cabinet; replace the six (6)screws and lockwashers. SUPPLY to customer connections,and return POWER SUPPLY to service.* AMP #42660-2 or an ASSISTANCEWhen trouble is reported, verify the unit is properlyconnected and there are no broken connectionsleading to this in troubleshooting is available from thefactory.

7 When calling, you should have a VOM and atest set and be calling from the job site. Call (540)427-3900 and ask for Technical Support, or (540)427-6000 for Valcom 24-hour Automated Support orvisit our website at equipment is not field repairable. Valcom, Inc. maintains service facilities in Roanoke, VA. Should repairs be necessary, attach a tag to the unitclearly stating company name, address, phonenumber, contact person, and the nature of theproblem. Send the unit to:Valcom, and Return Hollins RoadRoanoke, VA 24019-5056 TROUBLESHOOTING CHARTP roblemSolution1. No Overload LED Blows Verify AC present at Check for blown Press circuit breaker to Locate and correct short circuit in output Verify total equipment POWER consumption does not exceed 4 Verify total equipment POWER consumption does not exceed 2 amps per Disconnect AC while making POWER LIMITED WARRANTYV alcom, Inc.

8 Warrants its products to be free from defects in materials and workmanship under conditions of normal use and servicefor a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair orrefund of any such defective device within the warranty period, provided by Valcom, Inc. indicates the validity of the claim, defect is not the result of damage, misuse, or negligence after the original product has not been altered in any way or repaired by others and that factory sealed units are unopened (A servicecharge plus parts and labor will be applied to units defaced or physically damaged), charges for the return of products to Valcom are prepaid, units out of warranty are subject to a service charge.

9 The service charge will cover minor repairs (Major repairs will besubject to additional charges for parts and labor).This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. beliable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connectionwith the purchase, operation, or use of the warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, thecarrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with :In CanadaValcom, Corporation1111 Industry Avenue35 Van Kirk Drive #11 and 12 Roanoke, VA 24013 Brampton, Ontario L7A1A5 Phone: (540) 427-3900 Phone: (905) 456-1072 FAX: (540) 427-3517 FAX: (905) 456-2269 PAGECONTROL UNIT VP-4024 BPOWER SUPPLYA GROUNDA BATTERYB GROUNDB BATTERY-24V-24 VGNDGNDLOCGNDSTRAPEARTH OR COLDWATER PIPE GROUNDSTRAPFIGURE 1 - CONNECTIONS TO VALCOM PAGE CONTROL UNITSA lternate Ground Method: If using earth or coldwater pipe ground, do not connect to LOC GND.