Z-LOK Pipe to Manhole Connector Sell Sheet

Z LOK Cast In Boot Connector pipe TO Manhole Connector FOR SANITARY SYSTEMS The Company With ConnectionsThe Company With Connections The Z LOK pipe toManhole Connectorisa flexible connectorspecifically engineeredto produce a positivewatertight seal forpipes entering precastconcrete structures andthe structure heavier wall isdesigned to provide thehighest Z LOKCONNECTOR ismanufactured to meetor exceed therequirements set forthin ASTM C-923 titled Resilient ConnectorsBetween ReinforcedConcrete ManholeStructures, Pipes, andLaterals .Z LOK pipe to Manhole Connector The Z LOK CONNECTORis molded from an EPDM compoundengineered to conform with the requirements of section ofASTM C-923. Alternative compounds are available for unusualapplications upon special stainless steel hardware is in compliance with section , Mechanical Devices of ASTM C-923 and ADVANTAGESThe Z LOK Connector assures a positive watertight connection andprovides up to 25 of omnidirectional deflection and " of vertical orho rizontal movement without loss of seal, providing greater flexibility inthe design and installation of pipelines and structures.

Z•LOK Cast In Boot Connector PIPE TO MANHOLE CONNECTOR FOR SANITARY SYSTEMS The ComThe Compapany With ny With ConneConnectionsctions® The ZïLOK Pipe to Manhole Connector is a flexible connector specifically engineered

Tags:

  Pipe, Connectors, Manholes, Pipe to manhole connector, Lok pipe to manhole connector

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Z-LOK Pipe to Manhole Connector Sell Sheet

1 Z LOK Cast In Boot Connector pipe TO Manhole Connector FOR SANITARY SYSTEMS The Company With ConnectionsThe Company With Connections The Z LOK pipe toManhole Connectorisa flexible connectorspecifically engineeredto produce a positivewatertight seal forpipes entering precastconcrete structures andthe structure heavier wall isdesigned to provide thehighest Z LOKCONNECTOR ismanufactured to meetor exceed therequirements set forthin ASTM C-923 titled Resilient ConnectorsBetween ReinforcedConcrete ManholeStructures, Pipes, andLaterals .Z LOK pipe to Manhole Connector The Z LOK CONNECTORis molded from an EPDM compoundengineered to conform with the requirements of section ofASTM C-923. Alternative compounds are available for unusualapplications upon special stainless steel hardware is in compliance with section , Mechanical Devices of ASTM C-923 and ADVANTAGESThe Z LOK Connector assures a positive watertight connection andprovides up to 25 of omnidirectional deflection and " of vertical orho rizontal movement without loss of seal, providing greater flexibility inthe design and installation of pipelines and structures.

2 These designfeatures of the Z LOK Connector prevent infiltration due to shearcaused by settlement or ground inner rubber O-ring design eliminates rubber wrinkling,compensates for pipe irregularity and wall thickness insuring awatertight unique bi-directional design, permits the Z LOK Connector take-down clamp to be fastened from either the inside or outside of thestructure. Once fastened, immediate backfilling is possible enhancingpr oject safety and overcomes the normal problems encountered withwater, running sand and other unstable trench casting the Z LOK Connector into the structure, making it anintegral part of the wall, 50% of the opportunity for infiltration STANDARD The Z LOK CONNECTORSee following chart:MATERIALPRODUCT REFERENCESA.) ASTM C-923 Resilient Connector Between Reinforced Concrete manholes Structures, pipe and ) ASTM C-1244 Standard Test Method For Concrete Sewer manholes by the Negative Air Pressure (Vacuum) TestC.

3 ASTM C-478 Standard Specification for Precast Reinforced Concrete Manhole SectionsCopyright ASTM INTERNATIONAL. Reprinted with permissionTESTRESULTSASTM METHODC hemical resistance1 N Sulfuric acidno weight lossat 22 C for 48h1 N Hydrochloricno weight lossAcidTensile strength1200 psi orD MPa, minElongation at break350% 5 from mfg 2240specified hardness(Shore Adurometer)Accelerateddecr. of 15%,D 573,oven-agingmax. of original70 1 C fortensile strength,7 daysdecr. of 20%max. of elongationCompression setdecr. of 25%,D 395, Method B,max. of originalat 70 C for 22hdeflectionWater absorptionincrease of 10%,D 471, immersemax. of by 2-in. orby weight19 by 25-mmSpecimen indistilled waterat 70 C for 48hOzone resistance rating 0D 1171 Low-tempno fracture atD 746brittle point-40 CTear resistance200 624, Method Bor 34 kn/mRESILIENT TEST REQUIREMENTS OF C-923 MTD.) ASTM C-1644 Standard Specification for Resilient connectors BetweenReinforced Concrete On-Site Wastewater Tanks and Pipesmeets or exceeds all material and testrequirements of ASTM C-923-00 and ASTM LOK PRODUCTS BOX 1647 697 Main Street Tullytown, PA 19007 email: 215-547-3366 215-547-5260 FAXPRODUCT SPECIFICATIONSA flexible pipe to Manhole Connector shall be used whenever a pipe penetrates into a precast concrete Manhole or Connector shall be the Z LOK CONNECTORas manufactured by A LOKPRODUCTS, INC.

4 , Tullytown, PA, or approved design of the Connector shall provide a flexible, watertight seal between the pipeand concrete structure. The Connector shall assure that a seal is made between:(1) The Connector and the structure wall by casting the connectorintegrally with the structure wall during the manufacturing process in a mannerthat it will not pull out during pipe coupling.(2) The seal between the Connector and the pipe shall be made by compressingthe Connector against the outside circumference of the pipe by means of astainless steel take-down Connector shall be made from materials that conform to the physical andchemicalrequirements outlined in Section 4, Materials and Manufacture ofASTM C-923 Standard Specification for Resilient connectors BetweenReinforced Concrete Manhole Structures, Pipes, and Laterals , and the overalldesign will meet or exceed Section 7, Test Methods and Requirements of Connector shall be sized specifically for the type of pipe being used and shallbe installed in accordance with the recommendations of the INSTRUCTIONSWARNING:To ensure the Z-LOK Connectorremains a flexiblewatertight Connector , it is A LOK Products, Inc.

5 Strongrecommendation thatno mortarbe placed between the pipe andwall of the concrete structure. The use of mortar in this area woulddecrease the effectiveness of the Connector to compensate forshear caused by settlement or ground : The 60 Torque Wrench is available through A LOKP roducts, :When installing pipe stubs for future pipeline installation,all stubs must be properly restrained to prevent any movement bymeans other than the Z-LOK QUESTIONS REGARDING Z-LOK Connector ,PLEASE CALL 1-800-822-2565 PART 6 DIMENSIONAL DATAZ-LOKPIPE INCHESCLAMPRING CL-188C107-10 CL-188C107-12 CL-248C107-15 CL-EV15-18-LC107-16 CL-EV15-18-LC107-18 " " CL-EV15-18-LNOTE: F208-8 GASKET CAN BE USED ON C107-6 MANDREL WHEN ORDERING CLAMPS, pipe OD S ARE REQUIRED C107-1 AND C107-2 USE THE SAME MANDREL C107-16 AND C107-18 USE THE SAME MANDREL REDI-LOK CLAMP IS REQUIRED FOR C107-15 THROUGH C107-18 GASKETSSTEP 1:Bevel pipe ofdirt & debris.

6 OUTSIDE INSTALLATIONSTEP 2:Center pipe in Connector andpush 3:Attach proper size clampbeside o-ring then centerpipe in Connector and VERYIMPORTANT tighten clampwith torque wrench to 60inch NOTMORTAR60 IN. NOTMORTARTOP HALFOF PIPELINEZ-LOK Connector INWARD POSITIONINSIDE Z-LOK Connector INSTALLATIONSTEP 4:When installing a Z-LOKconnector in the outside themanhole position pull pipeback out after inserting sothe Connector flips outward,then VERY IMPORTANT -center pipe in connectorand tighten the take downclamp to 60 inch poundswith a torque pipe (mm)