Example: tourism industry

ZSE40A(F)/ISE40A - SMC ETech

2-Color Display High-Precision Digital Pressure Switch ZSE40A(F)/ISE40A Series . ZSE20. ISE20. IP65 ZSE30. RoHS ISE30. ZSE40. M8 connector type ISE40. ZSE10. ISE10. ISE70. ZSE80. ISE80. PS. ISA3. ISA2. ISE35. PSE. Applicable fluid Air, Non-corrosive gas, Non-flammable gas IS. ISG. Can copy to up to 10 switches simultaneously. The settings of the master sensor (source of copy) can be copied Easy handling! ZSM1. to the slave sensors. Reducing setting labor Minimizing risk of mistakes in setting Copy Raised rubber switch buttons for easy and Master sensor (source of copy). Slave 1 unit 2 units 10 units comfortable operation side 3-step setting 2-color display 1 2 3. See abnormal values at a glance.

M8 connector type 1 2 3 Applicable fluid Air, Non-corrosive gas, Non-flammable gas The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor Minimizing risk of mistakes in setting Can copy to up to 1100 switches simultaneously.

Tags:

  Switches, Zse40a, Ise40a

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ZSE40A(F)/ISE40A - SMC ETech

1 2-Color Display High-Precision Digital Pressure Switch ZSE40A(F)/ISE40A Series . ZSE20. ISE20. IP65 ZSE30. RoHS ISE30. ZSE40. M8 connector type ISE40. ZSE10. ISE10. ISE70. ZSE80. ISE80. PS. ISA3. ISA2. ISE35. PSE. Applicable fluid Air, Non-corrosive gas, Non-flammable gas IS. ISG. Can copy to up to 10 switches simultaneously. The settings of the master sensor (source of copy) can be copied Easy handling! ZSM1. to the slave sensors. Reducing setting labor Minimizing risk of mistakes in setting Copy Raised rubber switch buttons for easy and Master sensor (source of copy). Slave 1 unit 2 units 10 units comfortable operation side 3-step setting 2-color display 1 2 3. See abnormal values at a glance.

2 Push Push Adjust to the set-value Completion by the or button. of setting 45. Piping Variations Space-saving 44. R1/8, NPT1/8. Rc1/8, G1/8 M5 x ZSE/ISE40 Series 4, 6. Rc1/8, G1/8 One-touch fitting M5 x New ZSE/ ise40a Series Mounting Variations Bracket A Bracket B Bracket D Direct mounting Panel mounting (Wall mounting). Interchangeable with the ZSE40/ISE40 series for mounting Series Secret code setting function A function to prevent operation by anyone other than the Series zse40a ZSE40AF ise40a designated operator while the keys are locked. (vacuum pressure) (compound pressure) (positive pressure). OUT. 1. An optional 3-digit OUT value is entered. 2. The set-value can be checked while the keys are locked.

3 Power-saving function The display can be turned off to save the power consumption. to kPa to kPa to MPa (Power consumption reduced by max. 20%). 1 MPa The value disappears OUT. Rated pressure 100 kPa 1. range OUT. and decimal points 0 0 0. 2 start flashing. MPa 101 kPa 100 kPa ( 100 kPa) Resolution conversion function The flickering on the display can be eliminated. Set pressure range to kPa to kPa to MPa OUT OUT. 1 1. Withstand OUT OUT. pressure 500 kPa 500 kPa MPa 2 2. 1/1000 1/100. (Only the displayed value is changed, Min. unit setting kPa kPa MPa and there is no effect on the accuracy.). MPa/kPa switching function NPN or PNP open collector 2 outputs (with copy function). Output NPN or PNP open collector 2 outputs +.

4 The indication unit for vacuum, compound pressure and Analog output (voltage or current)/Auto-shift input positive pressure can be integrated into either MPa or kPa. Stick the OUT. 1. OUT. 1 label (enclosed R1/8, NPT1/8 (With M5 female thread), Rc1/8, G1/8, M5 female thread with the product). Piping OUT OUT. 4, 6 One-touch fitting 2 2 of a desired unit seal. 46.. 2-Color Display High-Precision Digital Pressure Switch RoHS. ZSE40A(F)/ISE40A Series ZSE20. ISE20. How to Order ZSE30. ISE30. Rated pressure range ZSE40. ise40a to MPa ISE40. ZSE10. For positive pressure ise40a 01 X M ISE10. ISE70. For vacuum/. compound pressure zse40a 01 Y M Made to Order ZSE80. ISE80. Rated pressure range Option 2 Symbol Specifications/Description zse40a to kPa Symbol Calibration certificate Note).

5 X501 Lead wire length 3 m PS. Piping M12 4-pin pre-wired ZSE40AF to 100 kPa Nil specifications X531 connector R1/8, NPT1/8. K (Lead wire length 100 mm) ISA3. R1/8. 01 (With M5 female thread). Note) All texts in both Refer to page 66 for details. M5 x Option 1 . English and Japanese ISA2. NPT1/8. N01 (With M5 female thread) Nil None Rc1/8, G1/8 Bracket A. ISE35. W1 Rc1/8. A PSE. WF1 G1/8 1 Rc1/8, G1/8. IS. Bracket B. M5 M5 x (Female thread). ISG. B. M5 x ZSM1. C4 4 One-touch fitting Bracket D. C6 6 One-touch fitting 4, 6 One-touch fitting D. Made to Order Conforming to ISO228-1. Combination of piping specifications with option 1 and part numbers of options Panel mount adapter Option 1 Piping Description Symbol Part no.

6 01 N01 W1 WF1 M5 C4 C6 01/N01. Bracket A A ZS-24-A. Bracket B B ZS-24-B. Bracket D D ZS-24-D. ZS-35-C E. Panel mount adapter E. ZS-35-D. Panel mount adapter + ZS-35-F. F. Front protective cover ZS-35-G. Output specifications W1/WF1/M5/C4/C6. X NPN open collector 2 outputs (with copy function). Y PNP open collector 2 outputs (with copy function) Panel mount adapter +. R NPN open collector 2 outputs + Analog voltage/Auto-shift switching Front protective cover T PNP open collector 2 outputs + Analog voltage/Auto-shift switching 01/N01. S NPN open collector 2 outputs + Analog current/Auto-shift switching V PNP open collector 2 outputs + Analog current/Auto-shift switching When optional parts are required separately, Options 1/Part No.

7 Use the following part numbers to place an order. Unit specifications Part no. Option Nil With unit switching function Note 1) F. ZS-24-A Bracket A Mounting screw M3 x 5L, M4 x 5L (2 pcs. for each) M Fixed SI unit Note 2). ZS-24-B Bracket B Mounting screw M4 x 5L (2 pcs.) With unit switching function Note 1). ZS-24-D Bracket D Mounting screw M3 x 5L, M4 x 5L (2 pcs. for each) P (Initial value psi). ZS-35-C Panel mount adapter (Piping: For 01/N01) Note 1) Under the New W1/WF1/M5/C4/C6. Panel mount adapter Measurement Law, sales of ZS-35-D (Piping: For W1/WF1/M5/C4/C6) switches with the unit Panel mount adapter + Front protective cover switching function are not ZS-35-F (Piping: For 01/N01) allowed for use in Japan.

8 Some options are unavailable depending on the piping specifica- Panel mount adapter + Front protective cover Note 2) Unit: kPa, MPa tions. Refer to Combination of piping specifications with option 1. ZS-35-G (Piping: For W1/WF1/M5/C4/C6) and part numbers of options . 47. ZSE40A(F)/ISE40A Series How to Order [For M8 (3 pins) connector]. Rated pressure range ise40a to MPa For positive pressure ise40a 01 N M L. For vacuum zse40a 01 N M L. Rated pressure range Option 2. Symbol Operation manual Note) Calibration certificate Note). zse40a to kPa Nil . Y . Piping specifications K . 01 R1/8 (M5 female threaded) T . Note) All texts in both English and Japanese N01 NPT1/8 (M5 female threaded).

9 Output specifications Option 1. N NPN open collector 1 output Nil None P PNP open collector 1 output Bracket A. A. Unit specifications Nil With unit display switching function Note 1). M Fixed SI unit Note Note 2). With unit switching function Bracket D. P (Initial value psi) Note 1). Note 1) Under the New Measurement Law, Unit specifications sales of switches with the D. unit switching function are not allowed for use in Japan. Note 2) Unit kPa, MPa Options 1/Part No. M8 connector type . When optional parts are required separately, use the following part numbers to place an order. Part no. Option ZS-24-A Bracket A Mounting screw M3 x 5L, M4 x 5L (2 pcs. for each). ZS-24-D Bracket D Mounting screw M3 x 5L, M4 x 5L (2 pcs.

10 For each). L. M8 connector No lead wires are connected. 48. ZSE40A(F)/ISE40A Series 2-Color Display High-Precision Digital Pressure Switch Refer to pages 11 and 12 for Pressure Switch Precautions. For details about the Specific Product Precautions, refer to the Operation Manual on the SMC website, Specifications Model zse40a (vacuum pressure) ZSE40AF (compound pressure) ise40a (positive pressure). Rated pressure range to kPa to kPa to MPa Display/Set pressure range to kPa to kPa to MPa Withstand pressure 500 kPa 500 kPa MPa ZSE20. ISE20. Display/Minimum unit setting kPa kPa MPa ZSE30. Applicable fluid Air, Non-corrosive gas, Non-flammable gas ISE30. Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (with power supply polarity protection).


Related search queries