Search results with tag "Disconnect"
Hubbell Circuit-Lock Motor Disconnects
hubbellcdn.comFused Disconnect Switches 3 Pole 600V AC Amp Description Catalog Number 30 Circuit-Lock fused disconnect switch FDS30* 60 Circuit-Lock fused disconnect switch FDS60* Auxiliary contact, normally open, A600 pilot duty HBLACFSNO Auxiliary contact, normally closed, A600 pilot duty HBLACFSNC Note: *Class "J" fuse not included. • UL 98 Rated Switch
POWER PRODUCT Disconnect Switches - Siemens
assets.new.siemens.com4-4 Siemens Canada Limited Power Product Catalogue 4 DISCONNECT SWITCHES Disconnect Switches Compact Non-Fusible — Rotary and Toggle Selection 0.31 in. (8 mm) F E C D A H G 0.16 in. (4 mm) B J 3LD2 16-250A Dimension Drawings and Wire Ranges Dimension J Minimum Deptha aDepth from outside of cover to back of switch. b Handle front plate …
Universal Visible-blade Flange Disconnect Switches ...
literature.rockwellautomation.comdisconnect switches. Universal visible-blade flange disc onnect switches can be user- or factory-assembled. The Allen-Bradley® 1494U universal visible-blade flange disconnect switch provides you with the extra level of visual ON or OFF indication of a …
Fused and Non-Fused Disconnect Switches Technical Data
literature.rockwellautomation.comThe Bulletin 194R line of fused and non-fused rotary disconnect switches provides the flexibility to meet worldwide applications. The disconnect switches are UL Listed and CSA Certified and are designed to meet IEC 60947-3, VDE, DIN, BS, and applicable NEMA requirements.
Installation, Operation, and ... - Arctic Chiller Group
www.arcticchillergroup.comdisconnect all power and discharge capacitors before servicing could result in death or serious injury. Disconnect all electric power, including remote disconnects, before servicing. Follow proper lockout/ tagout procedures to ensure that electrical power cannot be accidentally energized. Always use PPE and a
UL Standards Listing for Industrial Control Products
literature.rockwellautomation.comUL 98 WHTY E47426 Open Type Switch 30.1.6 194R • Fused and non-fused Rotary Disconnect Switches up to 1200 A • Typically used for disconnect and overcurrent protection of Feeder and IEC-style Type A motor starters 194U • Non-fused Rotary Disconnect switches up to 160 A • Designed for global applications 1494
Packaged Terminal Air Conditioner - Trane
www.trane.comDisconnect all electric power, including remote disconnects and discharge all motor start/run capacitors before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized. Verify with an appropriate voltmeter that all capacitors have discharged. Failure to disconnect power and discharge
Catalog Pages: Appleton™ Powertite™ Series Pin and Sleeve ...
www.emerson.comdisconnect switches (400 Amp plug is for disconnecting use ... MD2SR, or DBR explosionproof interlocking receptacles. • Controlled length contacts ensure that ground makes first and breaks last for added safety. ... 150 50 100 150 150 Do Not Disconnect Under Load 200 75 150 200 200 20 40 50 50
Centrifugal Inline Fans - Greenheck-USA
content.greenheck.comDisconnect Switch NEMA-1 disconnect switch is factory-mounted and wiring is provided from the motor as standard. All wiring and electrical components comply with the National Electric Codes and materials are UL Listed. Other NEMA enclosure disconnect switches are optional. Access Panels (not shown on images) The cabinet construction features two
BatteryProtect12/24 V ENGLISH
www.victronenergy.comThe BP will disconnect the load after 90 seconds and the relay will disengage. • In case of over voltage, the load will be disconnected immediately and the alarm output will remain inactive. Overvoltage trip levels: 16 V respectively 32 V Li-ion mode: • Connect the load disconnect output of the VE.Bus BMS to pin 2 -1.
Timing Light (basic) - Innova
csr.innova.comBE CAREFUL when working near high-voltage parts (spark plugs or coil terminals). Turn off ignition before connecting (or disconnecting) any testing equipment. ... disconnect and reconnect the timing light's positive battery clip from ... Press Cylinder/Advance Increment and Decrement switches as needed to
EatonHansen Quick Disconnect Coupling Catalog
hydraulicindustrial.comStraight Through Couplings Contents and Selection Chart 61 ST Series 62-64 P2-ST & P3-ST Series 65 FLO-TEMP 200/300/500 Series 66-67 Gas Couplings Gas-Mate Series 69 Accessories FS Flow Sensor Series 71 In-Line Check Valves 72 Flex-Air Fittings 73-74 Fittings 76 Elastomer Selection Guide 77 Index Technical & Warranty 78 2 eaton Quick Disconnect ...
dimmer 1 4 emove middle sections 6 oPEraTion MacL-153M …
www.lutron.comr emove (but do not disconnect) existing devices 3 Mark wire on the co MMon terminal See Step 4 on reverse for details. See Step 8 on reverse for details. 5 FOR ILLUSTRATION remove middle sections (if ganging devices) 4 disconnect wires On both existing devices, mark the wire (for example, using electrical tape) that OR
Solar PV Post-Evaluation Checklist
www1.eere.energy.govDC disconnect is DC-rated and permanently installed and readily accessible AC disconnect is permanently installed and accessible Penetrations to building shell are sealed and fire resistance maintained Sum of PV breaker and panel main breaker less than 120% of panel rating Utility power connected
Catalog Pages: Appleton™ Powertite™ Series Pin and Sleeve ...
www.emerson.comPowertite™ Series Pin and Sleeve Plugs, Connectors and Receptacles NEC/CEC: Listed for Ordinary (Unclassified) Locations ... disconnect switches (400 Amp plug is for disconnecting use ... MD2SR, or DBR explosionproof interlocking receptacles.
Fittings and accessories for lubrication systems - SKF
www.skf.comCouplings 122 Valves 126 Navigation Adapters, plugs and washers 70 2. Introduction Pressure gauges 134 Manual grease guns 163 ... Low-pressure quick-disconnect couplings 123 Medium- and high-pressure quick-disconnect couplings 123 ...
Non-fused Rotary Disconnect Switch Specifications
literature.rockwellautomation.comNon-fused Rotary Disconnect Switch Specifications Technical Data Summary of Changes This publication contains the following new or updated informatio n. This list includes substantive updates only and is not intended to reflect all changes. Topic Page Updated fuse information 6 Corrected short-circuit current rating information labels 7
YASKAWA AC Drive GA700
www.yaskawa.eu.comDo not examine, connect, or disconnect wiring on an energized drive. Before servicing, disconnect all power to the equipment and wait for the time specified on the warning label at a minimum. The internal ... couplings, shaft keys, and machine loads before energizing the drive. Failure to obey can cause death or serious injury.
Workplace Relations Commission
www.workplacerelations.ielegislation, the purpose of which is, inter alia, to protect employees from working excessive hours. The Organisation of Working Time Act, 1997 (View full document here) The OWTA 1997 has its genesis in protecting the safety, health and welfare of those at work. The Act does not explicitly refer to a ‘Right to Disconnect’, but states that
HOSE FITTINGS - Eaton
www.eaton.comQuick Disconnect 268-345 Couplings Access., Equipment & 346-393 Assembly Instructions Technical Data 394-433 RETURN TO CONTENTS PAGE. FC636 74 FC639 72 FC645 140 72 FC659 FC690 135 FC693 74 FC699 FC701 139 FC702 139 FC735 74 72 FC736 74 123 108 72 165 FC802 145 73 302A 145 73 303 145 73 1503 145 73 1529 74 72 158 73 1531 173 73 1531A …
What Type of Learner Are You? - University of Connecticut
achieve.uconn.edu7. At the end of 25 minutes, take a one-to-five minute break. Disconnect totally from your reading – exercise, relax, snack – whatever is comfortable for you. 8. After 25 minutes, take a one-to-five minute break, and review underlined material. 9. Review …
UCC Construction Code Communicator Index
www.nj.govAC Power Disconnect/Reconnect: Who can Do it? Fire Protection 2018 30 1 8 Acceptable Practices: Cleaning of Underground Storage Tanks Building 2001 13 1 9 Acceptance of Electronic Permit Applications Administrative 2015 27 4 2 Page 2 Updated 4/2022
Case 580e Super 580 E Backhoe ... - SERVICE REPAIR MANUAL
www.catexcavatorservicerepairmanual.comby J .I. Case Loader Control Valve Made by Parker Hannifin Steering Relief Valve and Quick Disconnect Couplings Three Point Hitch Control Valves Cylinders Backhoe Control Valve Stabilizer Control Valve 9- MOUNTED EQUIPMENT/CHASSIS Air Conditioning Troubleshooting Air Conditioning System Loader Three Point Hitch ROPS Cab and ROPS Canopy Seats ...
2020 OREGON ELECTRICAL SPECIALTY CODE
www.oregon.gov• 230.85 Oregon did not adopt new residential disconnect • 210.8 GFCI residential requirements mostly unchanged for 2021 3 of 157. Highlights continued • 210.8(F). ... ORS 479.835 Recovery of purchase price of product not meeting laws. 18 of 157. OAR 918-305-0030 Other Codes or Publications that Impact
Molded Case Circuit Breaker Specifications Technical Data
literature.rockwellautomation.comRotary Operators Internal Control Modules (Field installed) ... Main Disconnect Switch Application Yes, with accessories Application Conditions ... Bulletin 140U-D Molded Case Circuit Breaker Specifications Specifications Rockwell Automation Publication 140U-TD005B-EN …
BatteryProtect 65 A/100A/220A
www.victronenergy.comThe alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to
POWER TRANSMISSION SYSTEM
www.hillagric.ac.inClutch is a device, used to connect and disconnect the tractor engine from the transmission gears and drive wheels. Clutch transmits power by means of friction between driving members and driven members. Necessity of clutch in a tractor: Clutch in a tractor is essential for the following reasons: (i) Engine needs cranking by any
Lorem ipsum dolor sit amet - Eaton
www.eaton.comR9 Series Non-Fusible—Compact UL 98 (CSA 22.2 No.4) 30A, 60A and 100A See page 13 R9 Series Non-Fusible UL 98 (CSA 22.2 No.4) 100–1200A See page 20 R9 Series Fusible UL 98 (CSA 22.2 No.4) 30–800A See page 28 R9 Series DC Rated UL 98 (CSA 22.2 No.4) See page 47 MTS—Manual Transfer Switches See page 55 Enclosed Rotary Disconnects (R5) See ...
Stand Alone PV System Sizing Worksheet (example)
www.dnr.louisiana.gov6. Fused disconnects are strongly recommended to isolate the battery bank from the rest of the system. 7. Refer to electrical and mechanical design sections for other considerations. APPLICATION: Stand-alone camp system 7 miles off grid LOCATION: Baton Rouge, La LATITUDE: 31.53 degrees N A. LOADS (A1): Inverter efficiency (decimal).
CG General Purpose Application Controller Catalog Page
cgproducts.johnsoncontrols.comwithout the need to disconnect and reconnect the input/output wiring. Rotary switches for controller address/controller number Easy-to-use rotary switches set the MS/TP address or controller number in decimal format. Universal Inputs and Configurable Outputs Allows multiple signal options to provide input/ output flexibility.
HP Deskjet F4500 All-in-One series
h10032.www1.hp.comWhen the setup is finished, you will be prompted to disconnect the USB cable and test the wireless netw ork connection. Once the produc t connects successfully to the network, install the software on each computer that will use the product over the network. Related topics “Install the software for a network connection” on page 8 USB Connection
TECHNICAL SERVICE BULLETIN 19-2236 2.0L EcoBoost - Rattle ...
static.nhtsa.govDisconnect the fuel tube and EVAP canister purge valve quick release couplings. (Figure 14) Figure 14 21. Loosen the clamp and remove the charge air cooler (CAC) tube. (Figure 15) NOTE: When removing any turbocharger air intake system components, make sure to cover any open ports to prevent debris from entering the system.
Kia Full Map Navigation System
kia.navigation.comSwitch on your navigation system and wait until the system is completely booted. ii. Press Setup key for a minimum of 5 seconds and a configuration of your system will be displayed. iii. Note the Device ID (12 characters example: 001EB2D36510). ... Disconnect the USB flash drive and your navigation system is now ready for use.
Managed PoE+ Gigabit Switch with SFP
dl.ubnt.com1. Disconnect the Power Cord from the EdgeSwitch. 2. While connecting the Power Cord to the EdgeSwitch, hold the Reset button for about 15 seconds until the System LED flashes blue for two seconds. This indicates that the EdgeSwitch has reset to its factory defaults.
Hydratech Brochure - Hydratech General Trading LLC
www.hydratechuae.comHose Couplings, Clamps, Air King and Boss Couplings Complete Range Quick Disconnect Couplers Stainless Steel Hose Fittings, Adapters, 10k Test Fittings, High Pressure Needle Valves Fittings HAMMER UNIONS, Hook Blocks, Swivel – 150 Tons to 750 tons, Travelling Blocks & Hooks, Integral Fittings, OEM Spare parts, Long Sweep Manifold
Mental health and employers Refreshing the case for investment
www2.deloitte.comWorkplace Wellbeing Index. All of these measures are helping employers meet the mental health standards that were set out in the Thriving at Work Review. The national Thriving at Work Leadership Council was set up, and for the first time ... are unable to disconnect from
Automatic Transfer Switches - Kohler Co.
resources.kohler.comHazardous Voltage/ Moving Parts Hazardous voltage. Will cause severe injury or death. Disconnect all power sources before opening the enclosure. DANGER Hazardous voltage. Will cause severe injury or death. Only authorized personnel should open the enclosure. DANGER
Square D Safety Switches - ideadigitalcontent.com
www.ideadigitalcontent.comthe lifetime value of your safety switches. Safety switches play a crucial role in today’s commercial and industrial settings. They isolate power in daily activities and provide an effective way to interrupt power in an emergency. Two primary applications for safety switches are as a lockout on sight disconnect and as a circuit isolation device.
Silvertone Radio (parts list and instruction) (Sears)
lcweb2.loc.govAM ANTENNA DISCONNECT WHEN USING . CONNECTOR EX TERNAL fM ANTE N NA . ... ON-OFF SWITCH AND VOLUME CONTROL . TONE CONTROL . STATION SELECTOR . DIAL . TONE TUNING . AM . FM . ON -OFF . a . VOLUME . FUNCTION ... Motor speed control knob must be in "33" position. A stack of 10" and 12" long play records (33 -1/3 RPM) may be …
SFP Port Configuration - Cisco
www.cisco.cominterconnection of other high-performance switches and routers. SFP Support A SFP is a hot-swappable input/output device that plugs into the SFP ports, ... Do not twist or pull the tab because you may disconnect it from the SFP module. To remove the SFP module from the switchi ng module port, pull the tab gently in ...
Low Voltage Products Low Voltage Capacitor Banks Power ...
library.e.abb.comblown fuse indication, non-fused, fused disconnect switches and circuit breakers. Low losses Capacitor total losses are less than 0.5 watts per kvar. Auto-bank total losses (without reactors), including accessories such as Power Factor Controller and contactors are less than 1.5 watts per kvar. Unique sequential protection system
Nest Protect (Wired 230V) - Google Store
nest.comNest Protect should be installed at least 3 m (10 ft) away from cooktops or cooking appliances. Nest Protect should NOT be installed in unfinished attics or garages. 5. Figure 1 30 cm ... Disconnect them all. 6. Remove your old smoke alarm Make sure the green power light on the old
Disconnect Switch and Circuit Breaker Mechanism ...
literature.rockwellautomation.comDisconnect Switch and Circuit Breaker Mechanism Specifications Bulletin 1494C, 1494F, 1494G, 1494R, 1494V Disconnect Switches Disconnect Switch Electrical Ratings Switch Size 30 A 60 A 100 A 200 A 400 A 600 A Rated Insulation Voltage (UL) IEC - Ui (600) 660V Ratings UL/CSA/NEMA Hp 230V/60 Hz 460V/60 Hz 575V/60 Hz 7.5 15 20 15 30 50 30 60 75 60 ...
Disconnect switches Index - ABB
library.e.abb.comABB SwitchLine includes 16 different amperage sizes from 16A to 3150A. The basic construction provides flexibility, safety, and high performance in an extremely compact size. ABB SwitchLine is a perfect choice for all switching applications from industrial motor control to construction safety switches. Non-fusible Disconnect switches
Disconnect switches - ABBSales.com
abbsales.comABB SwitchLine is a perfect choice for all switching applications from industrial motor control to construction safety switches. ... AC 20/DC 20 enclosed A 25 32 40 63 80 40 63 115 160 ... Rated operational power AC23 400/415V kW 7.5 9 11 22 37 15 18.5 37 75 690V kW 7.5 9 11 15 18.5 15 15 37 75 Physical characteristics
Similar queries
Disconnects, Fused, Disconnect, Disconnect switches, Disc onnect switches, 1494U, 194R, Rotary Disconnect, Switch, Trane, Explosionproof, Disconnect Switch, BatteryProtect12/24 V ENGLISH, High, Voltage, Switches, Couplings, Solar, Powertite™ Series Pin and Sleeve, Fittings and accessories for lubrication systems, Disconnect couplings, Rotary Disconnect Switch Specifications, Rotary Disconnect Switch Specifications Technical Data, Protect, Eaton, What Type of Learner Are You, UCC Construction Code Communicator Index, Quick Disconnect Couplings, Oregon, Requirements, Meeting, Breaker Specifications, Rotary, Bulletin, Breaker Specifications Specifications Rockwell Automation, Alone PV System Sizing Worksheet example, Fused disconnects, CG General Purpose Application Controller Catalog Page, Quick, Quick Disconnect, Index, Control, Motor, Cisco, Disconnect Switch and Circuit Breaker Mechanism, Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin, 3150A, Switching, Enclosed, Power