DESIGN AND CONSTRUCTION GUIDELINES FOR MSE …

Report No. CDOT-DTD-R-2001-5 DESIGN AND CONSTRUCTION GUIDELINES FOR MSE WALLS WITH INDEPENDENT FULL-HEIGHT FACING PANELS Naser Abu-Hejleh Michael McMullen George Hearn Jorge G. Zornberg August 2001 COLORADO DEPARTMENT OF TRANSPORTATION RESEARCH BRANCH ii The contents of this report reflect the views of the authors, who are responsible for the facts and accuracy of the data presented herein. The contents do not necessarily reflect the official views of the Colorado Department of Transportation or the Federal Highway Administration. This report does not constitute a standard, specification, or regulation. iii Technical Report Documentation Page 1. Report No. CDOT-DTD- R- 2001- 5 2. Government Accession No. 3. Recipient s Catalog No. 5. Report Date August 2001 4. Title and Subtitle DESIGN AND CONSTRUCTION GUIDELINES FOR MSE WALLS WITH INDEPENDENT FULL-HEIGHT FACING PANELS 6.

The average lateral earth pressure measured on the facing was a low value of 32 psf. After five ... 0.836 square meters (m2) m2 1.195 yd2 acres (ac) 0.405 hectares (ha) ha 2.47 ac square miles (mi2) 2.59 square kilometers (km2) km2 0.386 mi2 VOLUME fluid ounces (fl oz) 29.57 milliliters (ml) ml 0.034 fl oz gallons (gal) 3.785 liters (l) l 0.264 ...