Backfill Material Selection
Where flowable fill is used, precaution must be taken to prevent flotation during installation. Table 1 Acceptable Backfill Material and Compaction Requirements Soil Classification Minimum Maximum* Compaction Description ASTM D2321 ASTM D2487 Standard Density (%) Layer Height (in.) Flowable Fill n/a n/a Dumped ** Graded or crushed stone
Download Backfill Material Selection
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
6-0 RETENTION/DETENTION SYSTEMS - assets.ads-pipe.com
assets.ads-pipe.comusing either larger diameter corrugated polyethylene pipe and a shorter overall system length, or by using smaller diameter pipe and a longer system length. The final decision depends on the size of the site, its groundwater level, and cover requirements. Figure 6-2 shows a typical cross-section of a retention/detention system. Table 6-2
System, Retention, Pipe, Detention, Corrugated, 6 0 retention detention systems
ADS N-12 WT IB PIPE (PER ASTM F2648) SPECIFICATION
assets.ads-pipe.comFittings Fittings shall conform to ASTM F2306. Bell and spigot connections shall utilize a welded bell and valley or saddle gasket meeting the watertight joint performance requirements of ASTM F2306. Field Pipe and Joint Performance To assure watertightness, field performance verification may be accomplished by testing in accordance with ASTM ...
Specification, Astm, Fitting, Pipe, Watertight, Fittings fittings, Per astm f2648, F2648
Pipe
assets.ads-pipe.comkPa) pressure testing requirements of ASTM D3212. Selection includes couplers, tees, wyes, elbows, caps and adaptors, each fitted with a rubber gasket. The fittings connect not only to corrugated HDPE pipe, but can adapt to PVC, concrete and other materials. inStallation Recommendation S
ADS HP STORM 12”- 60” PIPE SPECIFICATION
assets.ads-pipe.comAppropriate safety precautions must be used when field-testing any pipe material. Contact the manufacturer for recommended leakage rates. ... Backfill for minimum cover situations shall consist of Class 1 (compacted), Class 2 (minimum ... website at www.ads-pipe.com for a copy of the latest installation guidelines. Pipe Dimensions Nominal Pipe ...
HP Storm Pipe
assets.ads-pipe.comInstallation shall be in accordance with ASTM D2321 and ADS recommended installation guidelines, with the exception that minimum cover in traffic areas for 12– through 48–inch (300 to 1200 mm) diameters shall be one foot (0.3 m) and for 60–inch (1500 mm) diameters, the minimum cover shall be 2 feet (0.6 m) in single run applications.
ADS N-12 WT IB PIPE (PER AASHTO) SPECIFICATION
assets.ads-pipe.comMaterial for pipe and fitting production shall be high-density polyethylene conforming with the minimum requirements of cell classification 424420C for 4- through 10-inch (100 to 250 mm) diameters, and 435400C
ADS N-12 ST IB PIPE (ASTM F2648) SPECIFICATION
assets.ads-pipe.comThis specification describes 4- through 60-inch (100 to 1500 mm) ADS N-12 ST IB pipe (per ASTM F2648) for use in gravity-flow land drainage applications. Pipe Requirements ADS N-12 ST IB pipe (per ASTM F2648) shall have a smooth interior and annular exterior corrugations. • 4- through 60-inch (100 to 1500 mm) pipe shall meet ASTM F2648.
Specification, Astm, Pipe, Per astm f2648, F2648, Astm f2648
N-12 ST IB Pipe (per AASHTO)
assets.ads-pipe.comPipe Requirements ADS N-12 ST IB pipe (per AASHTO) shall have a smooth interior and annular exterior corrugations. • 4- through 10-inch (100 to 250 mm) shall meet AASHTO M252, Type S or SP • 12- through 60-inch (300 to 1500 mm) pipe shall meet AASHTO M294, Type S …
Pure Basin & Curb Inlet Filters
assets.ads-pipe.comInlet Filters Pure basin and curb inlet filters are the preferred choice for permanent inlet protection and stormwater runoff control. Constructed of versatile stainless steel, Pure inlet filters will fit any drainage structure and are available with site-specific filter bags providing various levels of filtration. Applications • Car washes
ADS SINGLE WALL PIPE SPECIFICATION
assets.ads-pipe.com*Pipe O.D. values are provided for reference purposes only, values stated for 12 through 24-inch are ±1 inch. Contact a sales representative for exact values **All diameters available with or without perforations.
Specification, Walls, Single, Pipe, Pipe o, Ads single wall pipe specification
Related documents
CHAPTER 8 RAILROAD - California Department of …
dot.ca.gov10. Slurry type materials are not acceptable as fill for soldier piles in drilled holes. Concrete and flowable backfill may prevent removal of the shoring system. Use compacted pea gravel material. 8.1.5 Information Required (GTS section 4, p3 - 4) Plans and calculations shall be submitted signed and stamped by a Registered Professional
Masonry Design - Texas A&M University
faculty-legacy.arch.tamu.eduGrout is a flowable mortar, usually with a high amount of water to cement material. It is used to fill voids and bond reinforcement. Clay and concrete masonry units are porous, and their durability with respect to weathering is an important consideration. The amount of water in the mortar is important as well as the
R11 Stormwater Drainage - Transport for NSW
roads-waterways.transport.nsw.gov.auDGB20 or controlled low strength flowable fill material. 3.6.3 . Part of previous sub- clause 3.6.6 under new sub-heading title “Precast Headwalls”. Subsequent sub- clauses renumbered. 3.6.6 . Content of previous sub-clause 3.6.2 moved here. 3.7.1 . Retitled “Backfilling”. Last para of previous sub-clause 3.6.3 on backfilling relocated ...
Stormwater, Fill, Drainage, Flowable, Flowable fill, R11 stormwater drainage
STANDARD SPECIFICATIONS - New York State Department …
www.dot.ny.govsection 554 - fill type retaining walls ..... 255232 section 555 - structural concrete ..... 280257 section 556 - reinforcing steel for concrete structures..... 295272 section 557 - superstructure slabs, sidewalks on bridges, and
To avoid adverse effects on humans, wildlife and the ...
www.nature.orgFill tank 1/4 to 1/2 full with carrier. Begin agitation. Add utility agents if needed (buffers) Add Dry pesticides: Wettable Powder (WP ) Add Wet pesticides: Flowable (F) Add Solution forming pesticides: Soluble (SP) Add Spray modifiers . Finish filling tank with carrier (ie. from hardest to dissolve to easiest)
Table 1A - Classes of Concrete - New Hampshire
www.nh.gov4 Maximum 84 day Compressive Strength for Flowable Fill, Excavatable shall not exceed 200 psi (1.4 Mpa). 5 These are recommended values that may be used as a starting point for a mix design that has shown ability to meet the requirements. The amount of …
Classes, New hampshire, Hampshire, Fill, Flowable, Flowable fill, Classes of
PRODUCT GUIDE - QUIKRETE
www.quikrete.comflowable grout, requiring only the addition of water. Available in Fine and Coarse. Use For: • Filling masonry block cores • Pumped or poured applications • Use Fine Core-Fill Grout when grout space is less than 4 inches in either direction • Use Coarse Core-Fill Grout when grout space it greater than 4 inches in either direction
THE CHEMISTRY OF LIFE !! ATOMS, MOLECULES, AND …
www.uc.eduThey will fill the shape of the container they are put in. pH OF LIQUIDS (pH stands for the potential of Hydrogen) Definition: A number value that expresses the acidity or alkalinity of a solution on which 7 is neutral, lower values are more acid and higher values more alkaline. ... (flowable). Particles are ...